Well Details

Well ID: 37-021-21091
Loading map...
Country: United States
State: Pennsylvania
County: Cambria
Municipality: Susquehanna Township
Operator Name: WILLIAM MCINTIRE COAL OIL & GAS
Well Pad ID:
Farm/Lease Name: RALPH LEWIS 10
License Status: Active
Spud Date: 09/02/2008
Permit Date: 7/23/2008
Unconventional Well: N
Configuration: Vertical Well
Latitude: 40.700326
Longitude: -78.751382

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 0.00 0.00 0.00
2009 0.00 0.00 0.00
2010 0.00 0.00 0.00
2011 WILLIAM MCINTIRE COAL OIL & GAS 1,449.00 211 0.00 0.00
2012 WILLIAM MCINTIRE COAL OIL & GAS 837.00 265 0.00 0.00
2013 WILLIAM MCINTIRE COAL OIL & GAS 841.33 226 0.00 0.00
2014 WILLIAM MCINTIRE COAL OIL & GAS 451.00 365 0.00 0.00
2015 WILLIAM MCINTIRE COAL OIL & GAS 234.00 110 0.00 0.00
2016 WILLIAM MCINTIRE COAL OIL & GAS 387.00 360 0.00 0.00
2017 WILLIAM MCINTIRE COAL OIL & GAS 153.00 10 0.00 0.00
2018 WILLIAM MCINTIRE COAL OIL & GAS 107.97 260 0.00 0.00

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-0 Produced Fluid (in Barrels) 180.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012-0 Produced Fluid (in Barrels) 90.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2013-0 Produced Fluid (in Barrels) 170.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014-0 Produced Fluid (in Barrels) 140.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2016-0 Produced Fluid (in Barrels) RWC 802 30.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1852608 Primary Facility 12/28/2009 Routine/Complete Inspection No Violations Noted According to record, operator completed the well on 9-9-08 to depth of 3818 ft. In reviewing well record, the well was "permanently cemented" with the proper calculated volume of cement to fill the annular space plus 20 %. In addition, the well head pressure is currently 600 psi (according to inactive application while site gauge showed 720 psi). The gas wellhead shut-in pressure in both cases does not exceed the 0.433 psi/foot of surface protective casing depth. Upon additional inspection of the well, the well head has been not properly well tagged. DEP could locate well tag at the wellhead. No signs of odors or leaks occurred around the well head. DEP called McIntire to confirm well head pressure and install/locate the permanent well tag.
1897055 Primary Facility 06/29/2010 Site Restoration No Violations Noted At time of inspection, well was drilled but not yet equipped for production. Inactive statues granted as of 1/19/10. Well was properly tagged. Site was adequately and uniformly restored with >70% vegetative cover. Access road was stable. No accelerated erosion or sedimentation issues were noted in relation to well site or access road. (During inspection accompanied with WQS Greg Higgins and Jarrod Shultz).
2647575 Primary Facility 2017-10-16 Routine/Complete Inspection No Violations Noted