37-003-22137

Well Details

Well ID: 37-003-22137
Loading map...
Operator Name: PENNECO OIL CO INC
First Permit Date: 2010-08-11
Last Permit Date: 2010-08-11
Spud Date: 2011-01-06
Unconventional: No
Horizontal: No
Violations: None
Latitude: 40.483527
Longitude: -79.81725

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-0 1194.0 243.0 0.0 0.0 0.0 0.0
2012-0 1983.0 305.0 0.0 0.0 0.0 0.0
2011-0 2591.0 245.0 0.0 0.0 0.0 0.0
2010-0 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2011-0 DRILLING FLUID WASTE 3370.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS COMPANY SALTSBURG PA
2011-0 FRACING FLUID WASTE 810.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472 TUNNELTON LIQUIDS COMPANY SALTSBURG PA

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1947181 2011-01-06 No Violations Noted USE RIG# 4 READY TO DRILL. PIT PROTECTED BY FENCING. PIT NOT LINED.
1947188 2011-01-07 No Violations Noted CONDUCTOR SANDED IN. USE RIG #4DRILLING AT 622'. SITE, PIT, E&S, AND ACCESS, OK.
1947924 2011-01-12 No Violations Noted On January 12th, 2011 I conducted a routine inspection of the above site. Drilling was taking place at the time of the inspection. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. Hay filter sock had been placed in behind the silt fence as an alternative to hay bales. A rip in the upper portion of the pit liner occurred the day earlier. The pit was drained and relined. No material escaped the drilling pit. The pit appears to be in good condition but its filling quickly. Water trucks were arriving on site at the time of inspection to begin hauling water away.
1951160 2011-01-14 No Violations Noted On January 14th, 2011 I conducted a routine inspection of the above site. Drilling was taking place at the time of the inspection. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The new pit liner appears to be intact and holding well. No spills, leaks, or accelerated erosion were observed during the inspection.
1952972 2011-01-20 No Violations Noted On January 20th, 2011 I conducted a routine inspection of the above site. Drilling was completed. Frac tanks were being moved in. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The pit is still in place and contains fluids. No spills, leaks, or accelerated erosion were observed during the inspection.
1953926 2011-01-11 No Violations Noted USE DRILLING AT 1890'. PIT LINER HAS ATEAR. DRILLING CEASED, THE PIT WAS DRAINED, AND A NEW LINER WAS INSTALLED.
1953928 2011-01-13 No Violations Noted USE RIG #4 IS DOWN FOR 7" CASING CEMENT TIME. PIT LINER HAS BEEN REPLACED FOR THE SECOND TIME.
1953929 2011-01-12 No Violations Noted USE DRILLING AT 1980'. SITE, PIT, E&S, AND ACCESS, OK.
1954049 2011-01-18 No Violations Noted APPALACHIA ON THE SITE TO CEMENT THE 4.5" CASING.

SITE, PIT, E&s, AND ACCESS, OK. PIT LEVEL OK.

1955523 2011-01-26 No Violations Noted DRILLING COMPLETE.

APPALACHIAN ON PAD TO FRAC. SITE, PIT, E&S, AND ACCESS OK.

1955699 2011-01-24 No Violations Noted DRILLING COMPLETE. TRUCKS FILLING FRAC TANKS.

SITE CLEAN AND PIT LEVEL OK.

1957394 2011-02-09 No Violations Noted WELL IS COMPLETE AND FRACED.

PRODUCTION EQUIPTMENT ON PAD BUT NOT HOOKED UP. SITE IS CLEAN AND DOZED. PIT LEVEL IS OK, AND E&S CONTROLS ARE STILL IN PLACE.

1957855 2011-02-03 No Violations Noted On February 3rd, 2011 I conducted a routine inspection of the above site. Drilling and frac were completed. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The pit is still in place and contains fluids. The liner appears to be in good condition and the pit had adequate freeboard. No spills, leaks, or accelerated erosion were observed during the inspection.
1957902 2011-02-08 No Violations Noted On February 8th, 2011 I conducted a routine inspection of the above site. Drilling and frac were completed. A site ID sign and E&S plan were posted at the site. The access road was in good condition. All E&S controls were in place and constructed according to the plan at site. The pit is still in place and contains fluids. The liner appears to be in good condition and the pit had adequate freeboard. No spills, leaks, or accelerated erosion were observed during the inspection.
1958909 2011-02-25 No Violations Noted On February 25th, 2011 I conducted a routine inspection of the above site. Drilling and frac were completed and the well was equipped for production. A site ID sign and E&S plan were posted at the site. The access road was in good condition. The pipeline was being installed. All E&S controls were in place and constructed according to the plan at site. The pit is still in place and contains fluids. The liner appears to be in good condition and the pit had adequate freeboard. No spills, leaks, or accelerated erosion were observed during the inspection.
1981543 2011-05-11 No Violations Noted WELL COMPLETE AND HOOKED UP. ANNULUS IS OPEN.

PITS ARE GONE. SITE IS CLEAN BUT NOT RESTORED.

1983663 2011-04-19 No Violations Noted On April 19th, 2011 I conducted a routine inspection of the above site. The well was in production. A site ID sign and E&S plan were posted at the site. The access road was in good condition. The pit was closed and the site grading has begun. No spills, leaks, or accelerated erosion were observed during the inspection. A well tag identifying the operator and permit number needs secured to the well.
1993784 2011-07-21 No Violations Noted THIS GAS WELL IS HOOKED UP AND PRODUCING. THE SITE IS NOT RESTORED. THE PIT IS GONE AND THE ACCESS IS STONED.
2107689 2012-10-16 No Violations Noted At the time of the inspection, the well site sign and label were on site. The well was drilled and equipped for production. The associated well apparatus located onsite appeared to be in sound working condition. There were no erosion or sedimentation issues. The area around the pad was restored and meets the 70% uniform vegetative coverage.
2134529 2013-01-16 Allegheny Penn Hills Twp No Violations Noted