If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-25561 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.903286,"lon":-80.201397,"icon":""}]} |
County: Greene | |
Municipality: Franklin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 147868 | |
Farm/Lease Name: BRUNO UNIT 2H | |
First Permit Date: 2010-08-17 | |
Last Permit Date: 2010-08-17 | |
Spud Date: 2010-12-11 | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 0 | |
Latitude: 39.903286 | |
Longitude: -80.201397 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-2 | 692001.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 463218.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 380388.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 290259.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 252958.0 | 153.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 33326.0 | 28.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 38295.0 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 37050.0 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2011-1 | DRILLING FLUID WASTE | 4.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2011-1 | FRACING FLUID WASTE | 9.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2011-2 | FRACING FLUID WASTE | 31.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2011-2 | FRACING FLUID WASTE | 5.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2012-1 | FRACING FLUID WASTE | 19.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2012-1 | FRACING FLUID WASTE | 480.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2012-2 | FLOWBACK FRACTURING SAND | 76.99 | Tons | LANDFILL | 073 114 654 | US ECOLOGY IDAHO, INC. | GRAND VIEW | ID |
2012-2 | FRACING FLUID WASTE | 2.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2012-2 | FRACING FLUID WASTE | 390.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2012-2 | PRODUCED FLUID | 3.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2013-1 | FRACING FLUID WASTE | 100.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2013-1 | FRACING FLUID WASTE | 97.5 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2013-1 | PRODUCED FLUID | 1.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | |||
2013-1 | PRODUCED FLUID | 890.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 | RONCO WASTE PROCESSING FACILITY | MASONTOWN | PA |
2013-2 | PRODUCED FLUID | 695.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-1 | PRODUCED FLUID | 570.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-1 | PRODUCED FLUID | 65.0 | Bbl | INJECTION DISPOSAL WELL | 34-121-23995 | WARREN DRILLING CO #1 (SWIW #6) | DEXTER CITY | OH |
2014-2 | PRODUCED FLUID | 420.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1941479 | 2011-01-08 | No Violations Noted | ||||
1970140 | 2011-02-02 | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The site construction appears to be complete and they are ready to begin drilling. The E/S controls appear to be in good condition. The pits/impoundments on site are built but not yet being used. This site is in a HQ watershed and special protection BMP﾿s will need to be maintained in order to prevent pollution. As per the ESCGP-1 requirement, the site will need to be inspected after a rainfall event and weekly. Please keep all E/S inspection reports on file. | |||
1974704 | 2011-02-08 | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. They are currently drilling a Marcellus Well on site. The E/S controls appear to be in good condition. The pits/impoundments appear to be in good condition. The driller was blowing a lot of dust across the site. The drill foreman explained that they got stuck down hole and it was temporary. This site is in a HQ watershed and special protection BMP﾿s will need to be maintained in order to prevent pollution. As per the ESCGP-1 requirement, the site will need to be inspected after a rainfall event and weekly. Please keep all E/S inspection reports on file. | |||
1976867 | 2011-05-16 | No Violations Noted | ||||
1987022 | 2011-04-20 | No Violations Noted | Minor slip at site. | |||
2001289 | 2011-05-16 | No Violations Noted | ||||
2027495 | 2011-09-06 | No Violations Noted | ||||
2067399 | 2012-03-26 | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. There are 2 Marcellus Wells drilled and appear to be in production at this location. The Well hit TD on 8-12-11 and the site should be restored and permanently stabilized on 5-12-12 with a uniform vegetative cover of 70%. Please make sure a restoration extension request is submitted if the site does not meet the restoration requirements within 9 months. The drill pits on site were empty but still contained a liner and were open. A stand-alone impoundment exists off site that contains only fresh water and will remain open. This impoundment can remain open as long as the ESCGP-1 requirements are met and it only contains fresh water. | |||
2083761 | 2012-06-19 | No Violations Noted | Minor Mod to ESCGP-1. Currently reclaimimg site and removing 1 sed trap and leaving 1 sed trap until they reach 70% uniform vegetative cover. |
For data sources see[3]