If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-25889 | | Well ID: 37-059-25889 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.761536, -80.007144 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Dunkard Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Greene_County,_Pennsylvania|Greene]] | ||
+ | |- | ||
+ | | Municipality: [[Dunkard Township,_Greene_County,_Pennsylvania|Dunkard Township]] | ||
|- | |- | ||
| Operator Name: [[CHEVRON APPALACHIA LLC]] | | Operator Name: [[CHEVRON APPALACHIA LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[148727]] |
|- | |- | ||
| Farm/Lease Name: LANCO UNIT 8H | | Farm/Lease Name: LANCO UNIT 8H | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Spud Date: 03/16/2012 |
|- | |- | ||
− | | | + | | Permit Date: 1/6/2012 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
| Latitude: 39.761536 | | Latitude: 39.761536 | ||
|- | |- | ||
| Longitude: -80.007144 | | Longitude: -80.007144 | ||
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2012 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2013 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 61,325.00 | ||
+ | | style="text-align: right;" | 17 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 1.00 | ||
+ | | style="text-align: right;" | 17 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 697,489.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 435,661.00 | ||
+ | | style="text-align: right;" | 366 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[CHEVRON APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 344,425.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 282,503.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[CHEVRON APPALACHIA LLC]] | |
− | + | | style="text-align: right;" | 63,224.00 | |
− | + | | style="text-align: right;" | 90 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | 0 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2012-1 | ||
+ | | Drilling Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 44.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
| 2012-2 | | 2012-2 | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,138.76 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100419 | | 100419 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2012-2 | | 2012-2 | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,640.00 Bbl |
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2013-1 |
− | |||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 20.00 Bbl |
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-1 | | 2013-1 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,317.70 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | | + | | |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | |- | + | | 2013-2 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,659.80 Bbl |
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,300.10 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | | + | | |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 3.87 Tons | ||
+ | | LANDFILL | ||
+ | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-1 |
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 28.33 Bbl |
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | + | | style="text-align: right;" | 266.67 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 270.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
− | | style="text-align:right;" | 8.28 | + | | style="text-align: right;" | 8.28 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Fracturing Fluid Waste (in Tons) | ||
+ | | style="text-align: right;" | 29.12 Tons | ||
+ | | STORAGE PENDING DISPOSAL OR REUSE | ||
+ | | MID074259565 | ||
|- | |- | ||
| 2014-1 | | 2014-1 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 2,528.67 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | | + | | 2014-2 |
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 450.67 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1.00 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | | + | | 2014-2 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 13.67 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | | + | | |
− | |||
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
| 2015-1 | | 2015-1 | ||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,235.00 Bbl |
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2015-1 | | 2015-1 | ||
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
− | | style="text-align:right;" | 15.43 | + | | style="text-align: right;" | 15.43 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2015-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 210.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-121-23995 | ||
|- | |- | ||
− | | | + | | 2015-1 |
− | | Produced Fluid (in Barrels) | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,794.00 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | REUSE | ||
| | | | ||
− | | | + | |- |
+ | | 2015-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1,731.67 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
|- | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 43.33 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016-1 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,238.33 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | REUSE | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 1,132.18 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016-2 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 123.34 Bbl |
− | + | | REUSE OTHER THAN ROAD SPREADING | |
− | | REUSE | ||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
+ | | 2017-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 120.44 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 148.17 Bbl |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | | | + | | WMGR123SW019 |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 290.29 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 130.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-04 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 76.67 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | 2017- | + | | 2017-04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 125.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-05 | | 2017-05 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,540.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-06 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 61.67 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 33.33 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 40.00 Bbl |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | | | + | | WMGR123SW001 |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 80.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 40.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-07 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 75.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 35.47 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
|- | |- | ||
| 2017-07 | | 2017-07 | ||
− | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 38.33 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-07 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 40.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-08 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 53.33 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 80.73 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | + | | INJECTION DISPOSAL WELL | |
− | | | + | | 34-059-24202 |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | + | | 2017-08 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 34.83 Bbl |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | | | + | | WMGR123SW019 |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | + | | 2017-08 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-09 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 190.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-09 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 71.67 Bbl |
− | |||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-10 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 29.98 Bbl |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | | | + | | WMGR123SW019 |
− | |||
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
| 2017-10 | | 2017-10 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 73.33 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE AT | ||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
− | + | | 2017-10 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-11 | | 2017-11 | ||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
− | | style="text-align:right;" | 36.67 | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-11 | | 2017-11 | ||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
− | | style="text-align:right;" | 96. | + | | style="text-align: right;" | 96.00 Bbl |
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-11 | | 2017-11 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 36.67 | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-157-25511 | | 34-157-25511 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-11 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 144.54 Bbl |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | | + | | |
− | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-12 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 156.67 Bbl |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | | + | | |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | |- | + | | 2018-01 |
− | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
− | + | | style="text-align: right;" | 36.02 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW019 | | WMGR123SW019 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2018-01 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.60 Bbl |
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW019 | | WMGR123SW019 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2018-01 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 74.00 Bbl |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | | + | | |
− | |||
− | |||
− | |||
− | | | ||
|- | |- | ||
− | | | + | | 2018-02 |
− | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 | |
− | | | + | | style="text-align: right;" | 120.00 Bbl |
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW001 |
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2018-02 |
− | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
− | + | | style="text-align: right;" | 146.67 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW005 |
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-02 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 74.00 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-02 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 37.33 Bbl |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | REUSE | ||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
+ | | 2018-03 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 18.33 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 33.33 | + | | style="text-align: right;" | 33.33 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-04 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 76.33 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-05 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-06 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2018-07 | | 2018-07 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 36.67 | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-09 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 36.67 | + | | style="text-align: right;" | 36.67 Bbl |
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-09 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | REUSE | ||
− | |||
− | |||
| | | | ||
− | |||
− | |||
|- | |- | ||
| 2018-11 | | 2018-11 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 73.33 | + | | style="text-align: right;" | 73.33 Bbl |
− | |||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-12 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 37.33 Bbl |
− | |||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2019-02 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 40.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE AT | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2019-03 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 60.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE AT | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Waste Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Inspection Category | ||
+ | !scope="col" | Inspection Date | ||
+ | !scope="col" | Inspection Type | ||
+ | !scope="col" | Inspection Result | ||
+ | !scope="col" | Inspection Comments | ||
+ | |- | ||
+ | | 2074543 | ||
+ | | Primary Facility | ||
+ | | 06/07/2012 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | KEANE 2143 DRILLING FOR CHEVRON. WERE DRILLING 8 5/8 HOLE @ 562'. CEMENT AND CASING INFO LOOKED GOOD .SITE LOOKED GOOD AT TIME OF INSPECTION. | ||
|- | |- | ||
− | | | + | | 2085153 |
− | | | + | | Primary Facility |
− | | | + | | 07/17/2012 |
− | | | + | | Drilling/Alteration |
− | | | + | | No Violations Noted |
− | + | | TOP HOLE DRILLED.PATTERSON 334 RIG ON SITE WILL MOVE TO THIS WELL WHEN THEY COMPLETE LANCO 7-H. SITE LOOKED GOOD AT TIME OF INSPECTION. | |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2304744 | ||
+ | | Primary Facility | ||
+ | | 07/17/2014 | ||
+ | | Follow-up Inspection | ||
+ | | Outstanding Violations - No Viols Req'd | ||
+ | | Well shut in not producing. | ||
|- | |- | ||
− | | | + | | 2331243 |
− | | | + | | Primary Facility |
− | | | + | | 11/19/2014 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | REVIEWED CALIPER LOGS AND CASING PRESSURE TESTS THAT WERE COMPLETED ON THE WELL BORE. REVIEWED WITH CHEVRON PERSONNEL THE NEW WELL HEAD EQUIPTMENT REPLACED ON THE WELL. |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2334377 | ||
+ | | Primary Facility | ||
+ | | 10/06/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Well shut in, and not in production. | ||
|- | |- | ||
− | | | + | | 2339127 |
− | | | + | | Primary Facility |
− | | | + | | 11/19/2014 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | Well completed. Well being placed into production. |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2476272 | ||
+ | | Primary Facility | ||
+ | | 2016-04-07 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | On 04/07/16 at approximately 0840 hours I conducted a routine complete inspection of the Lanco 6-8H well site in response to a restoration extension request submittal by Chevron. The Act 9 sign was in place and all required documents were present in the mail box. The site was stable. The original date for restoration was extended to October of 2014. Due to the extraordinary circumstances resulting from the loss of well control at the site in February of 2014, the Department is approving a new restoration date of October 31st, 2017. | ||
|- | |- | ||
− | | | + | | 2608634 |
− | | | + | | Primary Facility |
− | | | + | | 2017-06-19 |
− | | | + | | Routine/Partial/Aerial Inspection |
− | | | + | | No Violations Noted |
− | | | + | | An inspection was conducted in response to Gary Bowlen of Chevron requesting a meeting to discuss site restoration. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. Site restoration activities had begun. Portions of the access road are to be removed to reduce impermeable surfaces during phase I. Additional portions of the access road are to be removed during phase II. The phase II access road restoration activities have been approved to be completed in phase I. |
− | |||
− | |||
− | |||
|- | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--==== Penalties Applied ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Violation ID |
− | | | + | !scope="col" | Penalty ID |
− | | | + | !scope="col" | Penalty Code |
− | | | + | !scope="col" | Penalty Status |
− | | | + | !scope="col" | Penalty Date |
− | | | + | !scope="col" | Enforcement Date |
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
− | | | + | | 1 |
− | | | + | | 02/27/2013 |
− | | style="text-align:right;" | | + | | 02/27/2013 |
− | | | + | | style="text-align: right;" | 8071.0 |
− | | | + | | style="text-align: right;" | 5310032.0 |
− | | | + | | style="text-align: right;" | |
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="12"| 1 |
− | | | + | | rowspan="1"| Proppant (lbs) |
− | | | + | | rowspan="1"| |
− | | | + | | rowspan="1"| Proppant |
| | | | ||
− | |||
| | | | ||
− | | | + | | style="text-align: right;" | 9.79 |
+ | | style="text-align: right;" | 10.94214 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 7.5 Hcl Acid | ||
+ | | rowspan="1"| Reagent/PP G | ||
+ | | rowspan="1"| Used to open perfs | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 7.5 | ||
+ | | style="text-align: right;" | 0.14127 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| ASP 900 | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Ammonium Sulfate | ||
+ | | 7783-20-2 | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | None | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| GBL | ||
+ | | rowspan="1"| Clearwater | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 60.0 | ||
+ | | style="text-align: right;" | 0.00003000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC 6116a | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5.0 | ||
+ | | style="text-align: right;" | 0.00116 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | | 1,1-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | 0.00696 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | | Polyethylene Glycol |
− | | | + | | 25322-68-3 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 60.0 |
− | | | + | | style="text-align: right;" | 0.01392 |
− | | | + | | style="text-align: right;" | |
− | | | ||
− | |||
− | |||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Iron Control A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | 0.00698 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Scale Inhibitor A |
− | | style="text-align:right;" | | + | | rowspan="1"| Nalco |
− | | | + | | rowspan="1"| Scale Inhibitor |
− | | | + | | Ethylene Glycol |
− | | | + | | 107-21-1 |
− | + | | style="text-align: right;" | 30.0 | |
− | + | | style="text-align: right;" | 0.00698 | |
− | | | + | | style="text-align: right;" | |
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Unislik ST 50 | ||
+ | | rowspan="1"| CESI | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Hydrotreated Light Distillite | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.0 | ||
+ | | style="text-align: right;" | 0.03181 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Clean Volume (gals) |
− | | | + | | rowspan="1"| |
− | | | + | | rowspan="1"| Carrier/Base Fluid |
− | | | ||
| | | | ||
− | |||
| | | | ||
− | | | + | | style="text-align: right;" | 90.21 |
+ | | style="text-align: right;" | 100.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| CMHPG (lbs) | ||
+ | | rowspan="1"| Ashland | ||
+ | | rowspan="1"| Water Viscosifier | ||
+ | | Carboxymethylhydroxyporoyl guar blend | ||
+ | | Mixture | ||
+ | | style="text-align: right;" | 100.0 | ||
+ | | style="text-align: right;" | 0.00176 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-25889 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.761536,"lon":-80.007144,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Dunkard Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148727 | |
Farm/Lease Name: LANCO UNIT 8H | |
License Status: Active | |
Spud Date: 03/16/2012 | |
Permit Date: 1/6/2012 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.761536 | |
Longitude: -80.007144 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 61,325.00 | 17 | 0.00 | 0 | 1.00 | 17 |
2015 | CHEVRON APPALACHIA LLC | 697,489.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 435,661.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 344,425.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 282,503.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 63,224.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-1 | Drilling Fluid Waste (in Barrels) | 44.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-2 | Drill Cuttings (in Tons) | 1,138.76 Tons | LANDFILL | 100419 |
2012-2 | Drilling Fluid Waste (in Barrels) | 3,640.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-1 | Drilling Fluid Waste (in Barrels) | 20.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-1 | Fracing Fluid Waste (in Barrels) | 1,317.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Fracing Fluid Waste (in Barrels) | 3,659.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-2 | Fracing Fluid Waste (in Barrels) | 3,300.10 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Drill Cuttings (in Tons) | 3.87 Tons | LANDFILL | 100172 |
2014-1 | Drilling Fluid Waste (in Barrels) | 28.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-1 | Fracing Fluid Waste (in Barrels) | 266.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-1 | Fracing Fluid Waste (in Barrels) | 270.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracturing Fluid Waste (in Tons) | 8.28 Tons | LANDFILL | 100172 |
2014-1 | Fracturing Fluid Waste (in Tons) | 29.12 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID074259565 |
2014-1 | Produced Fluid (in Barrels) | 33.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Fracing Fluid Waste (in Barrels) | 2,528.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-2 | Fracing Fluid Waste (in Barrels) | 450.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 1.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-2 | Produced Fluid (in Barrels) | 13.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Fracing Fluid Waste (in Barrels) | 1,235.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-1 | Fracturing Fluid Waste (in Tons) | 15.43 Tons | LANDFILL | 100172 |
2015-1 | Produced Fluid (in Barrels) | 210.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2015-1 | Produced Fluid (in Barrels) | 3,794.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 1,731.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 43.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 1,238.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,132.18 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 123.34 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 120.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 148.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 290.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 76.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 125.00 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 1,540.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 61.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 35.47 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 38.33 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 53.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 80.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 34.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 190.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 71.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 29.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 36.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017-11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 96.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 144.54 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 156.67 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 36.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 36.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 74.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 120.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2018-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 146.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 74.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 37.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 76.33 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 73.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 37.33 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2074543 | Primary Facility | 06/07/2012 | Drilling/Alteration | No Violations Noted | KEANE 2143 DRILLING FOR CHEVRON. WERE DRILLING 8 5/8 HOLE @ 562'. CEMENT AND CASING INFO LOOKED GOOD .SITE LOOKED GOOD AT TIME OF INSPECTION. |
2085153 | Primary Facility | 07/17/2012 | Drilling/Alteration | No Violations Noted | TOP HOLE DRILLED.PATTERSON 334 RIG ON SITE WILL MOVE TO THIS WELL WHEN THEY COMPLETE LANCO 7-H. SITE LOOKED GOOD AT TIME OF INSPECTION. |
2304744 | Primary Facility | 07/17/2014 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Well shut in not producing. |
2331243 | Primary Facility | 11/19/2014 | Routine/Complete Inspection | No Violations Noted | REVIEWED CALIPER LOGS AND CASING PRESSURE TESTS THAT WERE COMPLETED ON THE WELL BORE. REVIEWED WITH CHEVRON PERSONNEL THE NEW WELL HEAD EQUIPTMENT REPLACED ON THE WELL. |
2334377 | Primary Facility | 10/06/2014 | Routine/Complete Inspection | No Violations Noted | Well shut in, and not in production. |
2339127 | Primary Facility | 11/19/2014 | Routine/Complete Inspection | No Violations Noted | Well completed. Well being placed into production. |
2476272 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted |
On 04/07/16 at approximately 0840 hours I conducted a routine complete inspection of the Lanco 6-8H well site in response to a restoration extension request submittal by Chevron. The Act 9 sign was in place and all required documents were present in the mail box. The site was stable. The original date for restoration was extended to October of 2014. Due to the extraordinary circumstances resulting from the loss of well control at the site in February of 2014, the Department is approving a new restoration date of October 31st, 2017. |
2608634 | Primary Facility | 2017-06-19 | Routine/Partial/Aerial Inspection | No Violations Noted | An inspection was conducted in response to Gary Bowlen of Chevron requesting a meeting to discuss site restoration. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. Site restoration activities had begun. Portions of the access road are to be removed to reduce impermeable surfaces during phase I. Additional portions of the access road are to be removed during phase II. The phase II access road restoration activities have been approved to be completed in phase I. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 02/27/2013 | 02/27/2013 | 8071.0 | 5310032.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant (lbs) | Proppant | 9.79 | 10.94214 | ||||
7.5 Hcl Acid | Reagent/PP G | Used to open perfs | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.14127 | ||
ASP 900 | Nalco | Friction Reducer | Ammonium Sulfate | 7783-20-2 | 30.0 | None | ||
GBL | Clearwater | Gel Breaker | Ethylene Glycol | 107-21-1 | 60.0 | 0.00003000 | ||
EC 6116a | Nalco | Biocide | Dibromoacetonitrile | 3252-43-5 | 5.0 | 0.00116 | ||
1,1-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.0 | 0.00696 | |||||
Polyethylene Glycol | 25322-68-3 | 60.0 | 0.01392 | |||||
Iron Control A | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30.0 | 0.00698 | ||
Scale Inhibitor A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30.0 | 0.00698 | ||
Unislik ST 50 | CESI | Friction Reducer | Hydrotreated Light Distillite | 64742-47-8 | 30.0 | 0.03181 | ||
Clean Volume (gals) | Carrier/Base Fluid | 90.21 | 100.0 | |||||
CMHPG (lbs) | Ashland | Water Viscosifier | Carboxymethylhydroxyporoyl guar blend | Mixture | 100.0 | 0.00176 |
For data sources see[7]