Well ID: 37-111-20306 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.757722,"lon":-79.356572,"icon":""}]} |
County: Somerset | |
Municipality: Addison Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 149073 | |
Farm/Lease Name: PMG GRACE UNIT 3H | |
First Permit Date: 2011-06-23 | |
Last Permit Date: 2011-06-23 | |
Spud Date: 2011-07-23 | |
Unconventional: Yes | |
Horizontal: Yes | |
Producing: No | |
Violations: None | |
Latitude: 39.757722 | |
Longitude: -79.356572 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
1997384 | 2011-08-04 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Chief contracted UDI. Toby Trip was representative for Chief. Conductor pipe set at 40 ft. (20¿¿pipe) and was grouted in place. 13 3/8¿ pipe set at 410¿ and used 315 sks of gas block (Universal cement) with 15 bbl. 9 5/8¿ pipe is going to be set at 2,144 feet with Universal performing cement using gas block. Deviation of hole is less than 1 %. DEP performed a site walk and did not find any issues. Current depth was 2,110 feet. | |
2003965 | 2011-09-08 | No Violations Noted | At the time of inspection, Well ID Sign, ES plan, and ESCGP-1 present. Access road entrance and roadway appear adequately rocked and stable. Well drilled and actively being vented while onsite, not yet in production. Temporary BMPs installed according to plan (both 12in and 18in compost soxs) and functioning. Noted ¿stressed¿ vegetation alongside and surrounding sediment traps. It appears as possible evidence that sediment traps are not properly functioning and/or water is improperly draining to traps. Although no (active) accelerated erosion or sedimentation issues are noted during this inspection, due to recent heavy rains, it is recommend that operator examine and monitor sediment traps and areas surrounding to ensure that proper drainage is occurring in order to prevent a possible pollution event. Noted red staining at toe slope of pad, again previously attributed to decomposition of mulch/tress. Accompanied by WQS Marc Maestra during inspection. | |
2016748 | 2011-11-03 | No Violations Noted | At the time of inspection, well sign (multi- well pad), ES Plan, ESCGP-1, PPC Plan present. Site gated and locked, as well as monitored by security. Access road and well pad adequately rocked and maintained. Well drilled. Well head surrounded by metal fence. No accelerated erosion or sedimentation issues noted during inspection. Bmp's are installed and appear to be functioning, although operator should continue to monitor and maintain all bmp's until final permanent restoration is complete. Previously disturbed areas have been temporarily seeded/mulched with observed growth. No violations noted during this inspection | |
2067337 | 2012-05-04 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Well head was modified in order to drill gas well 2H. | |
2078301 | 2012-06-20 | No Violations Noted | ||
2094696 | 2012-08-06 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Crown rig 8 was set up on well 2H to drill the curve and horizontal section. | |
2094822 | 2012-08-14 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Crown rig 8 was set up on well 2H to drill the curve and horizontal section. | |
2095548 | 2012-08-28 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Chevron had contracted Crown Rig #8. Current depth was 8200 feet. KOP was set at 8143 feet and TOM is estimated at 8700 ft. Currently, Chevron was in the process of changing drilling bit.
|
|
2107591 | 2012-10-09 | No Violations Noted | At the time of inspection the well appeared to be drilled but not equipped for production. The Erosion and Sedimentation plan was onsite and appeared to installed as outlined in the plan. No observation of accelerated erosion or sedimentation in relation to the well pad area or access road. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site is maintained. | |
2123143 | 2012-12-12 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was not in production |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | DRILLING FLUID WASTE | 100.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0253723 | APPALACHIAN WATER SERVICES LLC (RONCO WTP) | MASONTOWN | PA |
2012-2 | FRACING FLUID WASTE | 220.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | PA | ||
2011-2 | DRILLING FLUID WASTE | 1325.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0253723 | APPALACHIAN WATER SERVICES LLC (RONCO WTP) | MASONTOWN | PA |
2011-2 | DRILLING FLUID WASTE | 364.5 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | PA | ||
2012-1 | DRILLING FLUID WASTE | 2795.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0253723 | APPALACHIAN WATER SERVICES LLC (RONCO WTP) | MASONTOWN | PA |
2012-1 | DRILLING FLUID WASTE | 1170.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR DRILLING OR PLUGGING | PA |