If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-125-26932 | | Well ID: 37-125-26932 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.039494, -80.067297 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 06 | + | | Spud Date: 2013-06-20 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2013-01-16 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2015-03-10 | ||
+ | | 2015-03-15 | ||
+ | | style="text-align: right;" | 7863 | ||
+ | | style="text-align: right;" | 5,723,880.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="18"| 1 | ||
+ | | rowspan="3"| B466 | ||
+ | | rowspan="3"| Schlumberger | ||
+ | | rowspan="3"| Friction Reducer | ||
+ | | Ammonium Acetate | ||
+ | | 631-61-8 | ||
+ | | style="text-align: right;" | 6 | ||
+ | | style="text-align: right;" | 0.00081035 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Distillates (petroleum), hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00405177 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Alcohol Ethoxylates | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.0006753 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| A264 | ||
+ | | rowspan="4"| Schlumberger | ||
+ | | rowspan="4"| Corrosion Inhibitor | ||
+ | | Aliphatic alcohols, ethoxylayed #1 | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00002983 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Prop-2-yn-1-ol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00000994 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Aliphatic acids | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00002983 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00003977 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6486A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00074968 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Proppant | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Proppant | ||
+ | | Crystalline Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 10.6239 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15% Acid | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Perf Cleanup | ||
+ | | Hydrocloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.00874854 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| L058 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Iron Stabilizer | ||
+ | | Sodium erythorbate | ||
+ | | 6381-77-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00053452 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J134 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gel Breaker | ||
+ | | Hemicellulase enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00174901 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | rowspan="1"| Chevron | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water (Including Mix Water Supplied by Client) | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 89.2084 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00137537 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00011461 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00068769 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| EC6673W | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Iron Control | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00070409 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| J580 | ||
+ | | rowspan="1"| Schlumberger | ||
+ | | rowspan="1"| Gelling Agent, Water | ||
+ | | Carbohydrate Polymer | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0340899 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 138: | Line 327: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 200.70 Tons | | style="text-align: right;" | 200.70 Tons | ||
Line 144: | Line 333: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 2,760.00 Bbl | | style="text-align: right;" | 2,760.00 Bbl | ||
Line 150: | Line 339: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 263.54 Tons | | style="text-align: right;" | 263.54 Tons | ||
Line 156: | Line 345: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 279.53 Tons | | style="text-align: right;" | 279.53 Tons | ||
Line 162: | Line 351: | ||
| 100592 | | 100592 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 185.57 Tons | | style="text-align: right;" | 185.57 Tons | ||
Line 168: | Line 357: | ||
| 100663 | | 100663 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 181.11 Bbl | | style="text-align: right;" | 181.11 Bbl | ||
Line 174: | Line 363: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 27.22 Bbl | | style="text-align: right;" | 27.22 Bbl | ||
Line 180: | Line 369: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 11.11 Bbl | | style="text-align: right;" | 11.11 Bbl | ||
Line 186: | Line 375: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 101.90 Tons | | style="text-align: right;" | 101.90 Tons | ||
Line 192: | Line 381: | ||
| 100172 | | 100172 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 5.20 Tons | | style="text-align: right;" | 5.20 Tons | ||
Line 198: | Line 387: | ||
| 100663 | | 100663 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,564.56 Bbl | | style="text-align: right;" | 1,564.56 Bbl | ||
Line 204: | Line 393: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 31.33 Tons | | style="text-align: right;" | 31.33 Tons | ||
Line 210: | Line 399: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 74.44 Bbl | | style="text-align: right;" | 74.44 Bbl | ||
Line 216: | Line 405: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 494.44 Bbl | | style="text-align: right;" | 494.44 Bbl | ||
Line 222: | Line 411: | ||
| WMGR123SW001 | | WMGR123SW001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 0.03 Bbl | | style="text-align: right;" | 0.03 Bbl | ||
Line 228: | Line 417: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 5,158.33 Bbl | | style="text-align: right;" | 5,158.33 Bbl | ||
Line 234: | Line 423: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 0.60 Tons | | style="text-align: right;" | 0.60 Tons | ||
Line 240: | Line 429: | ||
| MID0209062814 | | MID0209062814 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 5,549.44 Bbl | | style="text-align: right;" | 5,549.44 Bbl | ||
Line 246: | Line 435: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 28.67 Bbl | | style="text-align: right;" | 28.67 Bbl | ||
Line 252: | Line 441: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 4,559.83 Bbl | | style="text-align: right;" | 4,559.83 Bbl | ||
Line 258: | Line 447: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 2,090.64 Bbl | | style="text-align: right;" | 2,090.64 Bbl | ||
Line 264: | Line 453: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 404.58 Bbl | | style="text-align: right;" | 404.58 Bbl | ||
Line 270: | Line 459: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | ||
| style="text-align: right;" | 0.06 Tons | | style="text-align: right;" | 0.06 Tons | ||
Line 276: | Line 465: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 93.75 Bbl | | style="text-align: right;" | 93.75 Bbl | ||
Line 282: | Line 471: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 86.88 Bbl | | style="text-align: right;" | 86.88 Bbl | ||
Line 288: | Line 477: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 25.78 Bbl | | style="text-align: right;" | 25.78 Bbl | ||
Line 294: | Line 483: | ||
| 34-119-28776 | | 34-119-28776 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 5.00 Bbl | | style="text-align: right;" | 5.00 Bbl | ||
Line 300: | Line 489: | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 15.91 Bbl | | style="text-align: right;" | 15.91 Bbl | ||
Line 306: | Line 495: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 148.21 Bbl | | style="text-align: right;" | 148.21 Bbl | ||
Line 312: | Line 501: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Other Oil & Gas Wastes (in Tons) RWC 899 | | Other Oil & Gas Wastes (in Tons) RWC 899 | ||
| style="text-align: right;" | 0.03 Tons | | style="text-align: right;" | 0.03 Tons | ||
Line 318: | Line 507: | ||
| 101532 | | 101532 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 41.25 Bbl | | style="text-align: right;" | 41.25 Bbl | ||
Line 324: | Line 513: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 163.88 Bbl | | style="text-align: right;" | 163.88 Bbl | ||
Line 330: | Line 519: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 54.63 Bbl | | style="text-align: right;" | 54.63 Bbl | ||
Line 336: | Line 525: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 28.38 Bbl | | style="text-align: right;" | 28.38 Bbl | ||
Line 342: | Line 531: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 41.00 Bbl | | style="text-align: right;" | 41.00 Bbl | ||
Line 348: | Line 537: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 12.50 Bbl | | style="text-align: right;" | 12.50 Bbl | ||
Line 354: | Line 543: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 4.38 Bbl | | style="text-align: right;" | 4.38 Bbl | ||
Line 360: | Line 549: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 14.38 Bbl | | style="text-align: right;" | 14.38 Bbl | ||
Line 366: | Line 555: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 53.63 Bbl | | style="text-align: right;" | 53.63 Bbl | ||
Line 372: | Line 561: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 41.50 Bbl | | style="text-align: right;" | 41.50 Bbl | ||
Line 378: | Line 567: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 13.75 Bbl | | style="text-align: right;" | 13.75 Bbl | ||
Line 384: | Line 573: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 41.25 Bbl | | style="text-align: right;" | 41.25 Bbl | ||
Line 390: | Line 579: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 28.13 Bbl | | style="text-align: right;" | 28.13 Bbl | ||
Line 396: | Line 585: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 28.75 Bbl | | style="text-align: right;" | 28.75 Bbl | ||
Line 402: | Line 591: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 10.63 Bbl | | style="text-align: right;" | 10.63 Bbl | ||
Line 408: | Line 597: | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 56.75 Bbl | | style="text-align: right;" | 56.75 Bbl | ||
Line 414: | Line 603: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 36.88 Bbl | | style="text-align: right;" | 36.88 Bbl | ||
Line 420: | Line 609: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 26.25 Bbl | | style="text-align: right;" | 26.25 Bbl | ||
Line 426: | Line 615: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 69.38 Bbl | | style="text-align: right;" | 69.38 Bbl | ||
Line 432: | Line 621: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 13.75 Bbl | | style="text-align: right;" | 13.75 Bbl | ||
Line 438: | Line 627: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 162.63 Bbl | | style="text-align: right;" | 162.63 Bbl | ||
Line 444: | Line 633: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 450: | Line 639: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 91.88 Bbl | | style="text-align: right;" | 91.88 Bbl | ||
Line 456: | Line 645: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
Line 462: | Line 651: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,325.00 Bbl | | style="text-align: right;" | 1,325.00 Bbl | ||
Line 468: | Line 657: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 14.38 Bbl | | style="text-align: right;" | 14.38 Bbl | ||
Line 474: | Line 663: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 137.50 Bbl | | style="text-align: right;" | 137.50 Bbl | ||
Line 480: | Line 669: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 13.75 Bbl | | style="text-align: right;" | 13.75 Bbl | ||
Line 486: | Line 675: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 116.25 Bbl | | style="text-align: right;" | 116.25 Bbl | ||
Line 492: | Line 681: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 51.25 Bbl | | style="text-align: right;" | 51.25 Bbl | ||
Line 498: | Line 687: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 72.50 Bbl | | style="text-align: right;" | 72.50 Bbl | ||
Line 504: | Line 693: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 13.75 Bbl | | style="text-align: right;" | 13.75 Bbl | ||
Line 529: | Line 718: | ||
| 2137338 | | 2137338 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-24 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 536: | Line 725: | ||
| 2182115 | | 2182115 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-02 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 543: | Line 732: | ||
| 2254621 | | 2254621 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-18 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 550: | Line 739: | ||
| 2256677 | | 2256677 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2014-03-25 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 557: | Line 746: | ||
| 2355728 | | 2355728 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-27 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 621: | Line 810: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-125-26932 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.039494,"lon":-80.067297,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: West Bethlehem Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 144580 | |
Farm/Lease Name: SARGENT UNIT 10H | |
License Status: Active | |
Spud Date: 2013-06-20 | |
Permit Date: 2013-01-16 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.039494 | |
Longitude: -80.067297 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-03-10 | 2015-03-15 | 7863 | 5,723,880.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | B466 | Schlumberger | Friction Reducer | Ammonium Acetate | 631-61-8 | 6 | 0.00081035 | 0 |
Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.00405177 | 0 | ||||
Alcohol Ethoxylates | Proprietary | 5 | 0.0006753 | 0 | ||||
A264 | Schlumberger | Corrosion Inhibitor | Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00002983 | 0 | |
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00000994 | 0 | ||||
Aliphatic acids | Proprietary | 30 | 0.00002983 | 0 | ||||
Methanol | 67-56-1 | 40 | 0.00003977 | 0 | ||||
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00074968 | 0 | |
Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 10.6239 | 0 | |
15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.00874854 | 0 | |
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.00053452 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 100 | 0.00174901 | 0 | |
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 89.2084 | 0 | |
EC6116A | Nalco | Biocide | Polyethylene Glycol | 25322-68-3 | 60 | 0.00137537 | 0 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00011461 | 0 | ||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00068769 | 0 | ||||
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00070409 | 0 | |
J580 | Schlumberger | Gelling Agent, Water | Carbohydrate Polymer | Proprietary | 100 | 0.0340899 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 830,265.00 | 162 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 1,146,257.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 670,368.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 485,435.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 100,681.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-S02 | Drill Cuttings (in Tons) | 200.70 Tons | LANDFILL | 100172 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 2,760.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Drill Cuttings (in Tons) | 263.54 Tons | LANDFILL | 100172 |
2014-S01 | Drill Cuttings (in Tons) | 279.53 Tons | LANDFILL | 100592 |
2014-S01 | Drill Cuttings (in Tons) | 185.57 Tons | LANDFILL | 100663 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 181.11 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Drilling Fluid Waste (in Barrels) | 27.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracing Fluid Waste (in Barrels) | 11.11 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Drill Cuttings (in Tons) | 101.90 Tons | LANDFILL | 100172 |
2014-S02 | Drill Cuttings (in Tons) | 5.20 Tons | LANDFILL | 100663 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 1,564.56 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S01 | Fracturing Fluid Waste (in Tons) | 31.33 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2015-S01 | Produced Fluid (in Barrels) | 74.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracing Fluid Waste (in Barrels) | 494.44 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 0.03 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2015-S02 | Fracing Fluid Waste (in Barrels) | 5,158.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracturing Fluid Waste (in Tons) | 0.60 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2015-S02 | Produced Fluid (in Barrels) | 5,549.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 28.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 4,559.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 2,090.64 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 404.58 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 0.06 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 93.75 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 86.88 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 25.78 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 5.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 15.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 148.21 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M01 | Other Oil & Gas Wastes (in Tons) RWC 899 | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 41.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 163.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 54.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 28.38 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 41.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 12.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 4.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 14.38 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 53.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 41.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 41.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 28.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 28.75 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 10.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 56.75 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 36.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 26.25 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 69.38 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 162.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 91.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 1,325.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 14.38 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 137.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 116.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 51.25 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 72.50 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2137338 | Primary Facility | 2013-01-24 | Routine/Complete Inspection | No Violations Noted | On January 24, 2013, I conducted a pre-drill E&S inspection at Chevron’s Sargent site in West Bethlehem Township, Washington County. |
2182115 | Primary Facility | 2013-07-02 | Drilling/Alteration | No Violations Noted | |
2254621 | Primary Facility | 2014-03-18 | Drilling/Alteration | No Violations Noted | Patterson Rig 334 |
2256677 | Primary Facility | 2014-03-25 | Drilling/Alteration | No Violations Noted | Patterson Rig 334 |
2355728 | Primary Facility | 2015-03-27 | Routine/Complete Inspection | No Violations Noted | On Friday March 27th 2015, I inspected the Sargent site in response to an extension request and made the following observations: |
2476237 | Primary Facility | 2016-03-24 | Complaint Inspection | No Violations Noted | On 3/24/16 water samples were collected for SAC 946 and bacterial count analysis in response to a complaint regarding the Sargent site. |
2476326 | Primary Facility | 2016-04-20 | Administrative/File Review | No Violations Noted | On 4/20/16, I performed an administrative review of sample results and site observation for a complaint related to the Sargent site and made the following observations:
•Water samples were found to have elevated hardness and iron levels; coliform and e. coli bacteria presence was also found indicating surface water influence. •Based on distance to nearest wells (~3000 and ~5000 feet away) and dates of most recent activity (4/19/15 and 9/4/10) as well as the above test results no oil & gas activity impact is indicated. |
2593528 | Primary Facility | 2017-05-15 | Routine/Complete Inspection | No Violations Noted | On May 15, 2017, I conducted a routine-complete inspection of the Sargent Well Site located in West Bethlehem Township, Washington County.
The Act 9 sign was in place and clearly legible at the site entrance which is secured with a locked gate. The well pad is also secured with a separate chain-linked fence and lock. The access road and the well pad are in good condition and the site is stabilized with vegetative growth. The secondary containment structure around the production tanks appears to be in good condition and functioning as intended. The gas wells appear to be in good working order and are labelled accordingly. No violations were identified during the inspection. |