34-019-22721

Well Details

Well ID: 34-019-22721
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Washington Township
Operator Name: PENNENERGY RESOURCES LLC
Well Pad ID: US-OH-001363
Farm/Lease Name: VAUGHN UNIT
License Status: Producing
License Date: 2016-07-20
Spud Date: 2016-06-29
Spud Drilling Contractor: SIDEWINDER DRILLING INC
Final Drill Date: 2016-07-29
Well Total Depth: 15456.00 ft
Configuration: Horizontal
Latitude: 40.630000
Longitude: -81.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-03-10 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:3/10/2016, Expired Date:3/10/2018 12:00:00 PM, Drilling unit acres:460.89, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2016-07-20 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:7/20/2016, Expired Date:7/20/2018 12:00:00 PM, Drilling unit acres:565.19, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2016-07-29
Correction to Well 2016-10-14 CHANGE IN TARGET/TALEPOINT AS DRILLED PLAT -ALE
Completion Report Received 2017-03-07
Construction Permit Expires 2018-07-20
Change of Owner 2018-10-03 Operator changed from 8894, R E GAS DEVELOPMENT LLC to 10212, PENNENERGY RESOURCES LLC
Record Last Modified 2018-10-03

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/30/2016 12/05/2016 7524 14,873,900.0 16,554,500.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 4.0 Guar Slurry ProFrac Proppant Transport Listed Below
ProBuff 300 ProFrac pH Buffer Listed Below
FR 7020 ECM Friction Reducer Listed Below
Ammonium chloride 12125-02-9 1 0.0002
Complex Ester 68607-07-8 30 0.00206
Ammonium persulfate 7727-54-0 100 0.00051 2485
Phosphorous acid 13598-36-2 1 0.00003000
Crystalline silica quartz 14808-60-7 1 0.00003000
Diatomaceous Earth, Natural (kieselguhr) 61790-53-2 5 0.00034
Water 7732-18-5 72 0.10462 551057
Sodium chloride 7647-14-5 5 0.00014
2-Propyn-1-ol compound w/ methyloxirane 38172-91-7 15 0.00021 1033
Water 7732-18-5 50 0.052 75016
Heavy Aromatic Naptha 64742-94-5 10 0.00069
Diatomaceous earth, calcined 91053-39-3 50 0.00138
Ammonium acetate 631-61-8 12 0.0125 18004
Silica Sand 14808-60-7 100 11.4913 16,554,500.0
Water 7732-18-5 75 0.0151
Methanol 67-56-1 30 0.00604
Hydrotreated petroleum distillate 64742-47-8 35 0.03645 52511
Mineral Oil 8042-47-5 5 0.00034
Chlorine dioxide 10049-04-4 0.3 0.00166
Ethoxylated alcohols 68002-97-1 4 0.00417 6001
Water 7732-18-5 30 0.00083
Distillate, petroleum, hydrotreated, light 64742-47-8 45 0.01878 90782
Sulphamidic acid 5329-14-6 5 0.00039 1862
Guar gum 9000-30-0 55 0.02259 110956
Hydrochloric acid 7647-01-0 28 0.04069 214300
Crystalline Silica:Quartz (SiO2) 14808-60-7 1 0.00007000
Phosphonic acid, sodium salt 15475-67-9 5 0.00014
Crystalline silica: Cristobalite 14464-46-1 1 0.00007000
Sodium hydroxide 1310-73-2 30 0.00019 915
Water 7732-18-5 100 86.1602 124,123,000.0
Ethoxylated alcohol 68551-12-2 4 0.00417 6001
Napthalene 91-20-3 1 0.00007000
Ethoxylated alcohols 68439-45-2 4 0.00417 6001
Water 7732-18-5 70 0.00539 26070
Sodium salt of Polyamino Phosphonate 1252600-17-1 20 0.00055
Trimethylbenzene 95-63-6 0.5 0.00003000
2-Propenoic acid, ammonium salt,

polymer with 2-propenamide, sodium salt

910644-97-2 45 0.0468 67515
Calcined Diatomaceous Earth 91053-39-3 100 0.00688
Water 7732-18-5 70 0.00044 2136
Water 7732-18-5 85 0.00121 5854
Acetic acid ethenyl ester, polymer with ethene 24937-78-8 5 0.00034
Citric acid 77-92-9 40 0.00308 14897
Organphosphonate 129828-36-0 15 0.00302
ProFE 105 ProFrac Iron Control Listed Below
Parasorb 5005 Baker Hughes Paraffin Inhibitor Listed Below
Sand ProFrac Proppant Listed Below
Water Rex Base Fluid Listed Below
Chlorine Dioxide Baker Hughes Biocide Listed Below
10% Acid Amrox Acidizing Listed Below
ProHib 100 ProFrac Acid Inhibitor Listed Below
ScaleSorb 12 Baker Hughes Scale Inhibitor Listed Below
ProBreak 100 ProFrac Oxidizer Listed Below
Scaletrol 767W Baker Hughes Scale Inhibitor Listed Below

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2016-12-05 H2O 0 7892 Bbl 0 STAGE 38/38

97 SHOTS

2016-10-27 H2O 0 7296 Bbl 0 STAGE 1/38

60 SHOTS STAGES 2-37 SEE IMAGES PRO FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 R E GAS DEVELOPMENT LLC 2018 10 5
2017 R E GAS DEVELOPMENT LLC 632659 22300 328
2018 PENNENERGY RESOURCES LLC 358981 8044 353
2019 PENNENERGY RESOURCES LLC 81371 1268 89

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 R E GAS DEVELOPMENT LLC Brine 0 5
2017 R E GAS DEVELOPMENT LLC Brine 35317 328
2018 PENNENERGY RESOURCES LLC Brine 9790 353
2019 PENNENERGY RESOURCES LLC Brine 1747 89

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1277871453 2016-7-2 0:00:0 DD No Violations 5.00
1162588018 2020-4-2 0:00:0 PL No Violations 1.00
1277871453 2016-07-02 Drill / Deepen / Reopen No Violations
1392528700 2018-06-20 Production Wells No Violations I conducted a status check of the well and production pad. The pad is equipped with four wells (permit numbers 2718, 2719, 2720, 2721) and this well is equipped with an open flow assembly. Proper identification was posted at the well and lease entrance. The tank battery is surrounded by a steel dike. The enclosed tank battery and contained less than one inch of standing water. I tested the standing water for chlorides using a low-range QuanTab, which concluded in a reading of under 33 pppm. The access road was stable and drivable. I performed an inspection of the perimeter of the pad, and erosional controls appeared to be in place and functioning.

Equipment on the pad consisted of the following:




I did not locate a surface-intermediate annular pressure gauge. I contacted operator who stated they in the process of acquiring gauges from the supplier, and an annular gauge will be installed as soon as possible.

1468865642 2016-06-30 Drill / Deepen / Reopen No Violations