34-029-20404

Well Details

Well ID: 34-029-20404
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: STUCKEY JOHN
License Status: Storage Well
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1952-04-02
Well Total Depth: 723.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1952-04-02 GL=1193.76, STORAGE CLEANED OUT 11/28/1951. I.P. NAT. = 3,146,880.
Reached Total Depth 1952-04-02 GL=1193.76, STORAGE CLEANED OUT 11/28/1951. I.P. NAT. = 3,146,880.
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17 GL=1193.76, STORAGE CLEANED OUT 11/28/1951. I.P. NAT. = 3,146,880.

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1583442429 2015-6-22 0:00: SO No Violations
-79582528 2020-4-6 0:00:0 SO No Violations 1.00
-999088048 2017-10-5 0:00: SO No Violations 0.20
0134502358 2013-05-08 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4154 today. The well is located in Section 36, Salem Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
0336666284 2014-11-07 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4154. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The annulus valve is plumbed up and closed. There was a sales line with a separator. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0999088048 2017-10-05 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0404. The lease access and well location were stable. Correct identification was present. Annular side ports were closed and plugged. The well casing was equipped with a master gate valve, side gate valve and a 4.5 flow line leading to a vertical drip that lead to the main line. No leaks were observed. No violations were observed during this inspection.
1233238895 2016-10-11 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1291666650 2010-11-24 Storage Well No Violations The Uniontown office received a call from Clark Bourque (615-585-2899) of Columbia Gas in Tennessee regarding a brine release at this well in their Berea storage field in Columbiana County. The onsite representative for Columbia Gas is David Reynolds The well was being killed with Rose Run brine when it kicked and flowed approximately 10 bbls of brine onto the ground. The area of soil affected was 5 feet in diameter. I told David Reynolds to remove and dispose of the brine saturated soil. Brett Farnsworth will follow up with David Reynolds regarding the remediation.
134502358 2013-5-8 0:00:0 SO No Violations
1576925259 2018-11-13 Storage Well No Violations The purpose of my inspection was to document the status of well #2-0241. Access to the well remained stable and drivable. Correct identification was present. The well head was above grade. The production casing annulus was closed to atmosphere. The top of the well head was equipped with a master gate valve and a flow tee. The top of the tee contained a swab valve connection. The side of the tee contained a wing valve that lead to a 4.5 run and vertical drip prior to the distribution system. All valves were closed. No leaks were observed.
1583442429 2015-06-22 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
336666284 2014-11-7 0:00: SO No Violations
680356940 2019-10-28 0:00 SO No Violations 1.00

For data sources see[3]