34-031-24474

Well Details

Well ID: 34-031-24474
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Perry Township
Operator Name: STRICKER CHARLES E & LENA
Well Pad ID:
Farm/Lease Name: NOVITSKY RICHARD & MARY LOU
License Status: Producing
License Date: 1981-08-04
Spud Date: 1981-08-15
Spud Drilling Contractor:
Final Drill Date: 1981-08-18
Well Total Depth: 3459.00 ft
Configuration: Vertical
Latitude: 40.290000
Longitude: -82.110000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-08-04 335 BERRESFORD ENTERPRISES IN GeoDate 8/4/81
Original Spud 1981-08-15
Completed 1981-08-18
Reached Total Depth 1981-08-18
CO 1994-03-08 4772 STRICKER CHARLES E & LENA GeoDate 8/4/81
Record Last Modified 2014-05-09

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3295 3332 16
3295 3332 16
3295 3332 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 45000 Gal 35000
ACID 0 250 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 BERRESFORD ENTERPRISES IN 0.00 67.00 365
1988 BERRESFORD ENTERPRISES IN 0.00 80.00 365
1992 HOOVER FRANK W DBA CHEROKEE DR 0.00 229.00 260
1993 BERRESFORD ENTERPRISES IN 0.00 0.00 365
1997 STRICKER CHARLES E & LENA 0.00 0.00 365
2001 STRICKER CHARLES E & LENA 0.00 0.00 0
2006 STRICKER CHARLES E & LENA 0.00 0.00 0
2007 STRICKER CHARLES E & LENA 0.00 0.00 0
2009 STRICKER CHARLES E & LENA 0.00 0.00 0
2010 STRICKER CHARLES E & LENA 0.00 0.00 0
2011 STRICKER CHARLES E & LENA 0.00 0.00 0
2012 STRICKER CHARLES E & LENA 0.00 0.00 0
2013 STRICKER CHARLES E & LENA 0.00 0.00 0
2014 STRICKER CHARLES E & LENA 0.00 0.00 0
2015 STRICKER CHARLES E & LENA 0.00 0.00 365
2016 STRICKER CHARLES E & LENA 0.00 41.00 365
2017 STRICKER CHARLES E & LENA 0.00 0.00 365
2018 STRICKER CHARLES E & LENA 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 BERRESFORD ENTERPRISES IN Brine 0 365
1988 BERRESFORD ENTERPRISES IN Brine 0 365
1992 HOOVER FRANK W DBA CHEROKEE DR Brine 155 260
1993 BERRESFORD ENTERPRISES IN Brine 0 365
1997 STRICKER CHARLES E & LENA Brine 0 365
2001 STRICKER CHARLES E & LENA Brine 0 0
2006 STRICKER CHARLES E & LENA Brine 0 0
2007 STRICKER CHARLES E & LENA Brine 0 0
2009 STRICKER CHARLES E & LENA Brine 0 0
2010 STRICKER CHARLES E & LENA Brine 0 0
2011 STRICKER CHARLES E & LENA Brine 0 0
2012 STRICKER CHARLES E & LENA Brine 0 0
2013 STRICKER CHARLES E & LENA Brine 0 0
2014 STRICKER CHARLES E & LENA Brine 0 0
2015 STRICKER CHARLES E & LENA Brine 55 365
2016 STRICKER CHARLES E & LENA Brine 57 365
2017 STRICKER CHARLES E & LENA Brine 63 365
2018 STRICKER CHARLES E & LENA Brine 95 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1021512507 2017-2-3 0:00:0 PW No Violations 1.00
-1574995351 2016-4-7 0:00:0 PW No Violations 3.50
000CEN3135 1998-12-01 Production Wells No Violations 1501:9-9-05
0592450860 2015-05-26 Production Wells Violations Noted On the day of my inspection I found that the wellhead was equipped with a pumping unit. The tank battery consisted of two 100 barrel tanks and one separator. There was a 30 barrel poly tank down by the road. There was no identification posted for this well. This well is in production. There was 0 mcf gas, and 0 barrels oil reported from 1993 to 2009. There have been no production reports filed since 2009. One of the 100 barrel tanks was leaking. There was crude oil and brine contamination inside of the dike. The side of the dike had been cut out to allow the oil and brine to run down the hill. There was a bare path of soil that was stained with oil that extended approximately 20 to 30 feet down the hill. There was also an open plastic line leading from the tank battery to the poly tank that had been running onto the ground. Repair or remove the leaking production equipment. Remove all of the contaminated soil from inside and outside the dike. Cap the plastic line with a shut off valve, and well identification must be posted.
0990242686 2015-08-05 Production Wells No Violations On the day of my inspection I found that identification had been posted on the 100 barrel tank. This violation is resolved.
1021512507 2017-02-03 Production Wells No Violations On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor and drive belts were intact, and the electric was connected. The flow lines were connected and the valves were open. The tank battery consisted of one 100 barrel steel tank and one vertical separator inside of an earthen dike, and one 30 barrel poly tank outside of the dike. Correct, legible identification was posted and I found no leaks or spills.
1067024101 2015-06-01 Administrative Inspection No Violations I received a phone call from well owner Lena Stricker. She claimed that they were in the process of trying to contract someone to clean up the contamination and repair the tank. I advised her on the identification requirements and proper disposal of the contaminated soil. She claimed that she has been turning in production reports to the County Auditor every year, so I provided her with Steve Rileys phone number at DOGRM Central Office to get her production reports up to date with the State. This well is used solely for domestic gas. However, it could not be permitted as an exempt domestic well because the Strickers do not own the property where the well is located.
1128355223 2005-10-03 Production Wells Violations Noted Well in production , Storage tank # 71497 is leaking from bottom of tank , Brine inside of dike starting to leach thru dike . Well name is NOVITSKY # 1 , PERRY TWP .
1131031016 2005-11-02 Production Wells No Violations Tank repaired .
1436897687 2015-07-14 Production Wells No Violations On the day of my inspection I found that the leaking tank had been turned and moved to a new dike. The contaminated soil had been removed from inside the old dike and from the hillside. The production reports have been brought up to date. There was still no identification posted. I contacted Mrs. Stricker to remind her that they need to identify the well in order to be in compliance.
1574995351 2016-04-07 Production Wells No Violations I received an email notification of complaint 5294 alleging that this well was idle and requesting enforcement action to have the well plugged. On the day of my inspection I found that the well was being produced with an electric powered pumping unit. The electric was connected at the motor and the belts were intact. The tubing and casing valves were open and the polished rod showed signs of recent use. There was new poly flow line connected at the wellhead and the soil showed signs of recent excavation from laying the line to the tank battery. There were no leaks or spills at the wellhead. The tank battery consisted of one 100 barrel steel tank, one 30 barrel poly tank and one vertical separator. An earthen dike was in place around the 100 barrel tank and the separator. There was also one 100 barrel steel tank inside of a dike that was not in use. The Strickers claimed that they had a contractor lined up to remove the old tank and restore the old dike area. The flow line to the separator was connected and the in-flow valve was open. The out-flow valve was also open and there were connected lines to the 100 barrel tank and to a drip bottle. The valve from the drip bottle was open to 1 poly gas line laid in the direction of the Stricker home. The gauge at the separator was hard to read, but I believe it showed approximately 100 psi. Identification was posted on the tank and there were no leaks or spills around the production equipment. I went to the Strickers home and met with Mr. and Mrs. Stricker. They claimed that they use the well primarily for domestic gas. Mr. Stricker claimed that he pumps the well one time a week for three hours, and the well makes approximately one tank of oil every five years. The tank did have fluid in it, but I could not determine the volume or composition. I observed an external gas hook up and regulator on the outside of the home. Both valves were open at the regulator. I also observed wall mounted gas heaters in a storage barn and a wo
592450860 2015-5-26 0:00: PW No Violations
990242686 2015-8-5 0:00:0 PW No Violations
CEN3135 1998-12-1 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0592450860 US-OH-126672 2015-08-27 Well operation causing pollution and contamination
0592450860 US-OH-126673 2015-08-27 Failure to legibly identify well
1128355223 US-OH-103249 2005-10-03 Well operation causing pollution and contamination

For data sources see[9]