X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-27145

Well Details

Well ID: 34-031-27145
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Pike Township
Operator Name: WHEELER MICHAEL D
Well Pad ID:
Farm/Lease Name: GAULT MARY
License Status: Producing
License Date: 2010-07-21
Spud Date: 2010-08-29
Spud Drilling Contractor: H & D DRILLING
Final Drill Date: 2010-09-13
Well Total Depth: 3139.00 ft
Configuration: Vertical
Latitude: 40.220000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-07-21 Proposed Formations:CLINTON, Issued Date:7/21/2010, Expired Date:7/20/2012 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-09-13
Completion Report Received 2010-10-15
Construction Permit Expires 2012-07-20
Change of Owner 2016-04-01 Operator changed from 1637, MACKENCO INC to 5476, WHEELER MICHAEL D
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-12-10 3050 3097 25
3050 3097 25
3050 3097 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-09-22 H2O 15 1465 Bbl 35000 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 MACKENCO INC 1134.00 180.00 90
2011 MACKENCO INC 1363.00 516.00 365
2012 MACKENCO INC 876.00 465.00 366
2013 MACKENCO INC 468.00 407.00 365
2014 MACKENCO INC 536.00 343.00 365
2015 MACKENCO INC 379.00 144.00 365
2016 MACKENCO INC 0.00 59.00 90
2017 WHEELER MICHAEL D 0.00 206.00 365
2018 WHEELER MICHAEL D 0.00 105.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 MACKENCO INC Brine 0 90
2011 MACKENCO INC Brine 100 365
2012 MACKENCO INC Brine 105 366
2013 MACKENCO INC Brine 80 365
2014 MACKENCO INC Brine 78 365
2015 MACKENCO INC Brine 0 365
2016 MACKENCO INC Brine 0 90
2017 WHEELER MICHAEL D Brine 80 365
2018 WHEELER MICHAEL D Brine 93 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1240060830 2010-8-3 0:00:0 DD No Violations
-1904319661 2010-8-4 0:00:0 DD No Violations
0086604588 2011-07-29 Production Wells No Violations Pumping well, capable of production.
0102589578 2016-07-19 Production Wells Violations Noted On the day of my inspection I found that the well was being produced with a natural gas powered pumping unit. The engine was intact, the lines were connected and the valves were open. The stuffing box was leaking, resulting in a 5 foot diameter area of standing crude oil and oil saturated soil around the wellhead. There was no identification posted at the wellhead. The tank battery is shared with permits 6947 and 6788, and consisted of two separate dikes. The upper dike contained three 100 barrel steel tanks, one 30 barrel poly tank and one vertical separator. The lower dike contained one 100 barrel steel tank. I found no leaks or spills at the tank battery. Correct, legible identification was posted at the tank battery. The issues that need to be addressed to bring this well into compliance are: remove the standing oil and saturated soil from around the wellhead; post correct, legible identification at the wellhead. I called Mike Wheeler to go over the compliance issues. He agreed to have everything taken care of within 30 days.
0735200860 2010-10-26 Preliminary Restoration No Violations Well in production. Pit and location graded and seeded. Vegetation started
0769851475 2016-09-07 Production Wells No Violations On the day of my inspection I found that the oil stained soil around the wellhead had been scraped up, and peat moss had been spread around the area. Correct, legible identification had been posted at the wellhead. The compliance issues have been resolved.
102589578 2016-7-19 0:00: PW No Violations 0.50
1240060830 2010-08-03 Drill / Deepen / Reopen No Violations I witnessed this surface cement job today.
1280857063 2010-08-03 Drill / Deepen / Reopen No Violations Drilling @ 400.
1544552610 2018-12-10 Production Wells No Violations On the day of my inspection I found that the identification sign was blank. Mike Wheeler has 5 wells on the Gault lease and 2 tank batteries. The wells are split as to which tanks they pump into, so I needed to call Mike Wheeler to ask that he get his ID signs refreshed. Mike said he would have it done by the end of next week.
1904319661 2010-08-04 Drill / Deepen / Reopen No Violations Running drill pipe to start drilling with power swivel .
2108180892 2010-08-02 Drill / Deepen / Reopen No Violations Drilling @ 300
735200860 2010-10-26 0:00 PL No Violations
769851475 2016-9-7 0:00:0 PW No Violations 0.30
86604588 2011-7-29 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0102589578 US-OH-100117 2016-09-29 Well operation causing pollution and contamination

For data sources see[9]

References