X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22088

Well Details

Well ID: 34-035-22088
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: HOLZMAN UNIT
License Status: Producing
License Date: 2008-12-01
Spud Date: 2009-07-21
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-07-26
Well Total Depth: 3532.00 ft
Configuration: Vertical
Latitude: 41.330000
Longitude: -81.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-01 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:12/1/2008, Expired Date:12/1/2009 6:00:00 AM, Drilling unit acres:21.27, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-07-26
Completion Report Received 2009-10-20
Construction Permit Expires 2009-12-01
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-11-13 3335 3390 21
3335 3390 21
3335 3390 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72000 Gal 48700

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 GONZOIL INC 750.00 893.00 365
2011 GONZOIL INC 2149.00 796.00 365
2012 GONZOIL INC 1405.00 557.00 366
2013 GONZOIL INC 1082.00 437.00 365
2014 GONZOIL INC 1308.00 416.00 365
2015 GONZOIL INC 976.00 255.00 365
2016 GONZOIL INC 819.00 265.00 365
2017 GONZOIL INC 916.00 276.00 365
2018 GONZOIL INC 289.00 88.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 GONZOIL INC Brine 659 365
2011 GONZOIL INC Brine 97 365
2012 GONZOIL INC Brine 110 366
2013 GONZOIL INC Brine 35 365
2014 GONZOIL INC Brine 70 365
2015 GONZOIL INC Brine 40 365
2016 GONZOIL INC Brine 25 365
2017 GONZOIL INC Brine 101 365
2018 GONZOIL INC Brine 0 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1035201231 2019-4-30 0:00: PW No Violations
-1140328054 2015-5-19 0:00: UP No Violations 1.00
-183496048 2014-3-25 0:00: UL No Violations
-2036397405 2015-6-26 0:00: UP No Violations
-2089847696 2010-2-1 0:00:0 DD No Violations
-820711854 2009-7-22 0:00: DD No Violations
-925848756 2017-5-1 0:00:0 UP No Violations 0.50
-932092119 2020-7-8 0:00:0 UP No Violations
0183496048 2014-03-25 UrbanPreliminary Restoration No Violations The unit is producing with no observed problems. Load-outs are locked and entry gates are locked. The ID placard is good. No signs of leaks or problems. The lease road is well maintained. ID placards, secondary containment, and process safety equipment is present. Spacing is compliant. The 8.625 casing is accessible.
0820711854 2009-07-22 Drill / Deepen / Reopen No Violations rigging up on site.
0925848756 2017-05-01 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery is separate chain-link enclosures located on a residential parcel, surrounded by woods . The enclosure gates were locked. Fittings and connections at both the wellhead and battery were secure. Load-line valves were plugged, locked and secure. The tank lids were closed and secure. Secondary containment was intact and the interior areas were dry and free from signs of leakage or problems. I walked and inspected the areas around the wellhead and battery and found no evidence of impact or environmental degradation relating to the on-going production activity.
1035201231 2019-04-30 Production Wells No Violations I conducted an inspection of the well and found no violation at well or tank battery.
1140328054 2015-05-19 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection. The wellhead and battery are located in a wooded area behind a single-family home. Access to the wellhead is via the shared driveway which continues for an additional 600 feet to the wellhead. Enclosure gates are locked and secure. ID signage is present and complete. Process safety gear is present. The production tank hatches are secure. At the time of this inspection I observed the following items requiring maintenance: The electrical box is unlocked and unsecure. There is oil staining around back-pressure (Baird) valve which requires clean-up. These maintenance issues must be remedied as soon as practicable or by 06/19/2015.
1174481982 2013-09-05 UrbanPreliminary Restoration No Violations The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate board-on-board enclosures. The battery is comprised of one 100-barrel production tank and one 20-barrel poly brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is a separate skid-mounted compressor unit located inside a third board-on-board enclosure. Unit ID is good. I did not observe any signs of leaks or spills. There is a very large, dead, red oak (48-inch diameter, 75 in height) which is beginning to lean over the tank battery. Im contacting Gonzoil to discuss possible intervention. The unit passes preliminary restoration.
1228129370 2013-10-28 UrbanProduction Wells No Violations I spoke with Doug Gonzalez about the dead tree over-hanging the battery. He indicated that they are aware and are making plans to cut the tree.
1563989303 2016-09-28 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead is located on a residential parcel, in a partially wooded area, with the wellhead and battery located within the same clearing. The wellhead chain-link enclosure was locked and secure. Fittings and connections at the well were secure and free from signs of leakage or problems. The battery chain-link enclosure was locked and secure. The fittings and connections were secure and free from signs of leakage or problems. The load-lines were locked, plugged and secure. The secondary containment was intact and free from signs of spills, leakage, or other problems. There was a stand-alone compressor unit located within a separate, board-on-board enclosure, which was secure. I walked the areas around the wellhead and battery and noted normal growth of vegetation with no signs of impact or environmental degradation.
1672327703 2011-10-31 UrbanPreliminary Restoration No Violations Urban Preliminary Restoration due. Preliminary Restoration passed.
2036397405 2015-06-26 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to an earlier inspection. On my previous inspection, I had noted that the electrical box was unlocked and there was some staining around the Baird valve. At the time of this inspection the issues have been resolved. The electrical box is locked. The leaking Baird valve has been fixed. The wellhead and battery enclosures are locked and secure. Load-lines are locked. Process safety equipment is present and in good condition. The fittings and connections are secure and free from signs of leakage. I met with the landowner and he expressed satisfaction with the on-going operations of the producing unit and responsiveness of the well owner. He reported no complaints.
2089847696 2010-02-01 Drill / Deepen / Reopen No Violations checking on well site crew working on grading and planting trees.

For data sources see[9]

References