X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-043-20079

Well Details

Well ID: 34-043-20079
Loading map...
Country: United States
State: Ohio
County: Erie
Municipality: Florence Township
Operator Name: FRANKLIN GAS & OIL CO LLC
Well Pad ID:
Farm/Lease Name: ERIE UNIT TRACT 1
License Status: Active Injection
License Date: 1983-04-22
Spud Date: 1982-12-08
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1982-12-10
Well Total Depth: 3965.00 ft
Configuration: Vertical
Latitude: 41.310000
Longitude: -82.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-05-19 Issued Date 5/19/82 Expired Date 11/15/82 Acres 0095000 Tool Type RTF Proposed Formation KRYSIK Proposed Depth 03965 Proposed Drill Depth 03965
Original Spud 1982-12-08 CONVERT 4-23-83
Completed 1982-12-10 CONVERT 4-23-83
Reached Total Depth 1982-12-10 CONVERT 4-23-83
CO 1983-04-22 2089 BALDWIN BALDWIN & H LOEB GeoDate 4/22/83
Enhanced Recovery 1983-04-22 Issued Date 4/22/83 Expired Date 10/19/83 Acres 0056000 Tool Type RTAF Proposed Formation KRYSIK SS Proposed Depth 03965 Proposed Drill Depth 03965
CO 1983-04-27 451 SUN EXPLORATION & PROD CO GeoDate 5/19/82
First Injection 1983-04-27 CONVERT 4-23-83
Completion Report Received 1983-05-05 CONVERT 4-23-83
Construction Permit Expires 1983-10-19 CONVERT 4-23-83
Annulus Pressure Monitoring Approved 1989-06-28 CONVERT 4-23-83
Change of Owner 1999-10-07 Operator changed from 2089, BALDWIN BALDWIN & H LOEB to 2491, MILLER ROY/RA MILLER ENER
Last Compliance Report 2000-02-03 CONVERT 4-23-83
Change of Owner 2005-04-04 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 65, FRANKLIN GAS & OIL CO LLC
Record Last Modified 2017-02-15 CONVERT 4-23-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 3865 3886 2
3865 3886 2
3865 3886 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2016-10-18 ACID 0 1200 Gal 0 Producers Service Corporation The packer and tubing were tripped out of the hole. The borehole was cleaned out to 26 feet below the bottom perforations. Frac sand and perf balls were recovered during clean out process. Current total depth is 3920 feet. The packer and tubing were run in the hole and not set for an acid treatment. Producers Service Corporation was onsite to perform an acid treatment. A total of 1200 gallons of 18% hydrochloric acid was pumped through 2 3/8 inch tubing to a depth of 3758 feet. The treatment
0 0 4000 1000 GAL 15% NEHCL, 4000# 20/60 SAND, 4000 GAL 4FP 35D

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 MILLER ROY/R A MILLER ENERGY L 0.00 0.00 0
2000 MILLER ROY/R A MILLER ENERGY L 0.00 0.00 0
2008 FRANKLIN GAS & OIL CO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 MILLER ROY/R A MILLER ENERGY L Brine 0 0
2000 MILLER ROY/R A MILLER ENERGY L Brine 0 0
2008 FRANKLIN GAS & OIL CO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1050604760 2007-9-24 0:00: ER No Violations
-1070096166 2014-10-3 0:00: ER No Violations
-1110213416 2013-7-22 0:00: ER No Violations
-1179667673 2003-12-24 0:00 ER No Violations
-1201521284 2010-5-24 0:00: ER No Violations
-1203738616 2006-9-27 0:00: ER No Violations
-1337446582 2010-9-16 0:00: ER No Violations
-1372476907 2007-1-29 0:00: SW No Violations
-1392677505 2014-7-7 0:00:0 ER No Violations
-1419011562 2016-11-21 0:00 WR No Violations
-1447126971 2015-4-13 0:00: ER No Violations
-1473857496 2017-7-19 0:00: ER No Violations
-1531076906 2010-10-4 0:00: ER No Violations
-1564064472 2019-1-2 0:00:0 ER No Violations
-1648675374 2012-9-10 0:00: ER No Violations
-1668684034 2010-3-29 0:00: ER No Violations
-1681013174 2016-7-20 0:00: WR No Violations
-1707727464 2010-7-26 0:00: ER No Violations
-1714909269 2008-3-19 0:00: ER No Violations
-1720450747 2013-2-28 0:00: SW No Violations
-1780755994 2003-2-26 0:00: ER No Violations
-1795172987 2014-4-9 0:00:0 ER No Violations
-1841879020 2016-2-4 0:00:0 ER No Violations
-184236560 2011-6-23 0:00: ER No Violations
-1887893807 2020-7-22 0:00: ER No Violations
-2008890522 2013-5-6 0:00:0 ER No Violations
-2053040697 2017-9-21 0:00: ER No Violations
-207926855 2005-3-30 0:00: ER No Violations
-2102064252 2017-1-11 0:00: ER No Violations
-2110265316 2010-1-27 0:00: ER No Violations
-2112006914 2002-12-12 0:00 ER No Violations
-247411970 2018-6-11 0:00: ER No Violations
-257243466 2008-12-9 0:00: ER No Violations
-27046802 2009-4-7 0:00:0 ER No Violations
-308123908 2018-1-24 0:00: ER No Violations
-343426248 2016-9-8 0:00:0 WR No Violations
-352176265 2005-5-2 0:00:0 ER No Violations
-434453044 2017-10-31 0:00 ER No Violations
-437288565 2015-10-7 0:00: ER No Violations
-450859686 2007-8-6 0:00:0 ER No Violations
-458394322 2005-2-24 0:00: ER No Violations
-464750673 2019-10-2 0:00: ER No Violations
-568164084 2017-4-12 0:00: ER No Violations
-586580303 2008-9-9 0:00:0 ER No Violations
-626324512 2004-5-26 0:00: ER No Violations
-62966963 2019-4-17 0:00: ER No Violations
-679041674 2018-4-3 0:00:0 ER No Violations
-684341126 2003-4-24 0:00: ER No Violations
-727229032 2018-8-9 0:00:0 ER No Violations
-773597141 2004-8-23 0:00: ER No Violations
-923010184 2007-3-26 0:00: ER No Violations
-924989700 2006-5-30 0:00: ER No Violations
-950653917 2016-7-12 0:00: ER No Violations
-965835651 2009-12-7 0:00: ER No Violations
-972801774 2016-10-14 0:00 WR No Violations
0002573469 2001-06-11 Enhanced Recovery Project No Violations Chk well and area. OK.
0015112178 2016-03-17 Enhanced Recovery Project Violations Noted Our records indicate that the Division has not received the Enhanced Recovery Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED 3/17/2016.
0025573659 2002-05-10 Salt Water Injection Well No Violations Chk well and storage OK.
0027046802 2009-04-07 Enhanced Recovery Project No Violations Inspect well.
0029073498 2002-07-11 Salt Water Injection Well No Violations Chk well and storage, OK.
0135356965 2012-06-05 Enhanced Recovery Project No Violations Inspect Well. Shut in.
0184236560 2011-06-23 Enhanced Recovery Project No Violations inspect well. Well shut in. no meter.
0207926855 2005-03-30 Enhanced Recovery Project No Violations Inspect Well during Annular test conducted by Gene Varner and witnessed by Jeff Fry.
0224191040 2004-06-17 Production Wells No Violations Inspect tanks to update coordinates.
0243806476 2005-07-28 Enhanced Recovery Project No Violations Inspect Well. Pump rate 178 bbl/day.
0247411970 2018-06-11 Enhanced Recovery Project No Violations Inspect well for pressure and integrity.
0249138180 2004-04-22 Enhanced Recovery Project No Violations Inspect well. Cannot collect Annulus pressure. Swage broken at threads, integrity compromised. Annulus shut in as a result of 2 inch valve. Appears someone was standing or jumping on pipe run and broke at swage. Notified assistant well tender. Well tender, Gene Varner, contacted inspector on 4/23/04 identifying knowledge of broken valves, had parts in truck and intended to replace on said date.
0257243466 2008-12-09 Enhanced Recovery Project No Violations Inspect well. Id posted. Site ok.
0265986005 2004-02-25 Enhanced Recovery Project No Violations Inspect Well. Packing for filter has a slow leak.
0269747690 2009-07-21 Enhanced Recovery Project No Violations Inspect well. Annulus pressured up to 80 psi. flow rate 3.7 bbl/day.
0277160991 2015-01-16 Salt Water Injection Well No Violations Inspect well for integrity and pressure. The well is shut in.
0308123908 2018-01-24 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The flow rate on the meter indicates zero barrels per day.
0343426248 2016-09-08 Work Over Reconditioning No Violations The operator has the service rig setup on the well. The packer has been released and about half of the tubing has been pulled and is on the rack.
0352176265 2005-05-02 Enhanced Recovery Project No Violations Inspect well. New digital BBL meter installed.
0354980613 2013-10-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Shut in.
0384646682 2011-01-26 Enhanced Recovery Project No Violations Inspect well. Check pressures. No meter, shut in.
0434453044 2017-10-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0437288565 2015-10-07 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well is shut in.
0450859686 2007-08-06 Enhanced Recovery Project No Violations Inspect Well. Site ok. 0 bbl/day. Annulus is zero.
0458394322 2005-02-24 Enhanced Recovery Project No Violations Inspect Well.
0458757607 2005-03-30 Salt Water Injection Well No Violations Witness mini MIT test. Company representative Gene Varner and Lenny. (This Friday water flood is supposed to be sold to Franklin Oil and Gas). Annulus pumped up with hand pump on mule buggy. Annulus full.

Test to 200 psi., after 5 min. 200 psi., after 15 min. 200 psi. TEST PASSED.

0568164084 2017-04-12 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well was shut in during the inspection.
0586580303 2008-09-09 Enhanced Recovery Project No Violations Inspect well and location with Jeff Fry. Identification is posted and ok.
0626324512 2004-05-26 Enhanced Recovery Project No Violations Inspect Well. Operator conducted monthly Annulus test. Pressured to 300 PSI. Held for 15 minutes. Zero percent loss.
0679041674 2018-04-03 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0684341126 2003-04-24 Enhanced Recovery Project No Violations Inspect Well. Annulus is under positive pressure. The pumper has been opening a valve on the water filter to discharge accumulated sediment. This practice has caused the ground vegetation to be stained and created a burn area.
0705943505 2003-06-23 Enhanced Recovery Project No Violations Inspect well. Actively injecting fluids.
0727229032 2018-08-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The meter is not working.
0773597141 2004-08-23 Enhanced Recovery Project No Violations Inspect Well. ID at well head posted. No ID posted at common tank.
0819818977 2004-06-28 Enhanced Recovery Project No Violations Inspect Well.
0876058176 2004-12-28 Enhanced Recovery Project No Violations inspect Well.
0923010184 2007-03-26 Enhanced Recovery Project No Violations inspect well.
0924989700 2006-05-30 Enhanced Recovery Project No Violations Inspect Well. Needle valve needs to be replaced. Site OK.
0934213797 2005-11-18 Enhanced Recovery Project No Violations Inspect Well. 180 bbl/day.
0945651873 2010-11-10 Enhanced Recovery Project No Violations Inspect well. Shut in. no meter.
0950653917 2016-07-12 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. This well is shut in.
0952506023 2009-09-22 Enhanced Recovery Project No Violations Inspect well and location. Zero bbl/day.
0965835651 2009-12-07 Enhanced Recovery Project No Violations Inspect well site. 5.6 bbl/day.
0972801774 2016-10-14 Work Over Reconditioning No Violations The operator previously pulled the packer and tubing. The operator tripped in the hole with a rebuilt Halliburton R4 packer for 5.5 inch casing on 121 joints of tubing. The borehole was cleaned out 26 feet of hole below the bottom perforations. Frac sand and perf balls were recover during clean out. Current total depth is 3920 feet. The packer and tubing was hung in the hole, to be set at a later date. The packer was placed in the hole in tension to set with counter clockwise turn.
0988408507 2018-10-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1006265397 2008-07-30 Enhanced Recovery Project No Violations Inspect well. Meter indicates low battery. Rate 0 bbl/day. Needle valve for injection line is very tight and is very hard to open or close.
1037286175 2015-07-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in.
1038096809 2003-10-21 Salt Water Injection Well No Violations Inspect Well. Annulus in on positive pressure. Location has been cleaned up from the leak that occurred during the previous inspection.
1050604760 2007-09-24 Enhanced Recovery Project No Violations inspect well. Site ok. Annulus is zero. Pump rate of 174 bbl/day.
1055433167 2012-01-30 Enhanced Recovery Project No Violations Inspect Well. Shut in.
1070096166 2014-10-03 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in.
1076302329 2017-06-13 Enhanced Recovery Project No Violations The operator is testing well to evaluate the efficiency of the well.
1106850753 2011-10-03 Enhanced Recovery Project No Violations Inspect well. Shut in.
1110213416 2013-07-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in.
1142423291 2006-03-27 Enhanced Recovery Project No Violations Inspect Well. Pump cycle off. Needle valve for annulus gauge over tightened, need to replace. Flow meter indicates 79 bbl/day. Spoke with pumper regarding needle valve.
1179667673 2003-12-24 Enhanced Recovery Project No Violations Inspect Injection Well.
1201521284 2010-05-24 Enhanced Recovery Project No Violations Inspect well. Well shut in. meter removed.
1202391880 2012-11-20 Salt Water Injection Well No Violations Inspect well for integrity and pressure. Well shut in.
1203738616 2006-09-27 Enhanced Recovery Project No Violations Inspect Well. 69 bbl/day.
1212588012 2008-06-04 Enhanced Recovery Project No Violations Inspect well and location. Pumping at 0 bbl/day.
1254886704 2007-05-21 Salt Water Injection Well No Violations Inspect well. Well head meter at 189 BBL per day.
1337446582 2010-09-16 Enhanced Recovery Project No Violations Inspect well. Site ok. Well shut in. no meter. Production line to well head has a hole and is in very poor condition.
1345637709 2006-07-31 Enhanced Recovery Project No Violations Inspect well. Pump shut down during inspection.
135356965 2012-6-5 0:00:0 ER No Violations
1372476907 2007-01-29 Salt Water Injection Well No Violations Inspect well. Rate 160 bbl/day. Pin hole leak at base of filter. Contacted pumper needs repair/ replacement.
1384353891 2007-11-15 Salt Water Injection Well No Violations Inspect facility. Site ok. Rate 195 bbl/day. Needle valve is hard to open and close.
1389963195 2014-01-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in and the flow lines are disconnected at the tank battery.
1392677505 2014-07-07 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in.
1402576096 2014-06-06 Enhanced Recovery Project No Violations Inspect well. Well is shut in.
1419011562 2016-11-21 Work Over Reconditioning No Violations The operator ran in the hole with 2 3/8 inch tubing with a Halliburton R-4 packer in 5.5 inch hole, set the packer, and loaded annulus with fresh water with rust inhibitor, and pressured well up to 1000 psi. The pressure was monitored for 15 minutes with zero pressure loss. The operator was notified that the well can be used for injection.
1435841754 2009-05-27 Enhanced Recovery Project No Violations Inspect well. Site ok. Id ok. Meter error.
1447126971 2015-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in. The valves are closed.
1473857496 2017-07-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well has a new meter installed.
1478706180 2016-10-18 Work Over Reconditioning No Violations Producers Service Corporation was onsite to perform an acid treatment. A total of 1200 gallons of 18% hydrochloric acid was pumped through 2 3/8 inch tubing to a depth of 3758 feet. The treatment rate was 1.2 gallons per minute with an average 552 psi. Upon completion of the well treatment, Producers pumped 60 barrels of water with inhibitor to clear the hole for setting the packer. The operator ran out of fresh water as well as the well was taking a significant amount of water. The operator then attempted and failed to set the packer. Subsequently the tubing and packer were tripped out of the hole, it was reported by the operator, the Halliburton R-4 packer was rebuilt with brass shear pins; the shear pins sheared when the initial attempt to set the packer occurred.
15112178 2016-3-17 0:00: ER No Violations
1531076906 2010-10-04 Enhanced Recovery Project No Violations Inspect well. Shut in.
1564064472 2019-01-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The pump house meter reads 17676 barrels at rate of 243 barrels per day.
1648675374 2012-09-10 Enhanced Recovery Project No Violations Inspect Well. Well shut in.
1668684034 2010-03-29 Enhanced Recovery Project No Violations Inspect well.
1681013174 2016-07-20 Work Over Reconditioning No Violations The operator was requested to investigate stray gas emanating near the well head. The operator excavated the well head and determined the 8 5/8 inch to 5.5 inch wellhead slips were leaking natural gas. The operator removed the ring and cleaned the rubber and threads. The well head was assembled and the leak was resolved.
1707727464 2010-07-26 Enhanced Recovery Project No Violations Inspect well. No meter. Shut in.
1714909269 2008-03-19 Enhanced Recovery Project No Violations Inspect facility. Rate 5.8 bbl/day.
1720450747 2013-02-28 Salt Water Injection Well No Violations At the time of my inspection the well was shut in.
1724997579 2006-01-25 Enhanced Recovery Project No Violations Inspect Well. Injection rate 173.2 bbl/day.
1735792917 2003-09-03 Enhanced Recovery Project Violations Noted Inspect Well site. Production/injection line is leaking below grade and is following the line to the surface and running off the immediate well head location. Gene Varner was on location and apprised of the situation and shut down system.
1752825005 2004-10-25 Enhanced Recovery Project No Violations Inspect Well. Pump shut down during inspection for maintenance and replacement of filters.
1775381192 2006-12-04 Enhanced Recovery Project No Violations Inspect well and test pressure. 54 bbl/day. Need to pressure annulus. Spoke with Ken.
1780755994 2003-02-26 Enhanced Recovery Project No Violations inspect well.
1784576965 2005-09-26 Enhanced Recovery Project No Violations Inspect Well.
1795172987 2014-04-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well is shut in. Tubing pressure is from the formation.
1808560240 2019-7-9 0:00:0 ER No Violations
1818115221 2016-04-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well is shut in.
1821079089 2011-04-04 Enhanced Recovery Project No Violations Inspected Well. Site OK. Well shut in.
1841879020 2016-02-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut-in.
2008890522 2013-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in. Injector pressure is the formation pressure.
2053040697 2017-09-21 Enhanced Recovery Project No Violations Inspect well. The flow meter indicates a rate of zero barrels per day.
2102064252 2017-01-11 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head tubing pressure was not collected because the well is shut in. The well has recently been serviced, the flow line has not been reconnected to the tubing.
2110265316 2010-01-27 Enhanced Recovery Project No Violations Inspect well. Site ok. 7.5 bbl/day.
2112006914 2002-12-12 Enhanced Recovery Project No Violations Well inspection. Annulus pressure is Zero. Monthly testing is required when pressure is Zero. Facility report is included in 20014 report for this date. Digital photos taken.
2132499604 2019-5-16 0:00: ER No Violations
2136091567 2008-01-23 Salt Water Injection Well No Violations inspect well. Site ok. Meter is too cold to give reading. Flow rate at 24 bbl /day.
224191040 2004-6-17 0:00: PW No Violations
243806476 2005-7-28 0:00: ER No Violations
249138180 2004-4-22 0:00: ER No Violations
25573659 2002-5-10 0:00: SW No Violations
2573469 2001-6-11 0:00: ER No Violations
265986005 2004-2-25 0:00: ER No Violations
269747690 2009-7-21 0:00: ER No Violations
277160991 2015-1-16 0:00: SW No Violations
29073498 2002-7-11 0:00: SW No Violations
354980613 2013-10-23 0:00 ER No Violations
384646682 2011-1-26 0:00: ER No Violations
458757607 2005-3-30 0:00: SW No Violations
473904031 2020-2-3 0:00:0 ER No Violations
705943505 2003-6-23 0:00: ER No Violations
810381099 2020-4-6 0:00:0 ER No Violations
819818977 2004-6-28 0:00: ER No Violations
876058176 2004-12-28 0:00 ER No Violations
934213797 2005-11-18 0:00 ER No Violations
945651873 2010-11-10 0:00 ER No Violations
952506023 2009-9-22 0:00: ER No Violations
988408507 2018-10-17 0:00 ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0015112178 US-OH-114306 2016-04-04 Failure to monitor pressures or volumes/failure to file
1735792917 US-OH-117240 2003-09-04 Pollution/Contamination

For data sources see[9]

References