{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.55,"lon":-84.23,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Fulton | |
Municipality: German Township | |
Operator Name: DON YOHE ENTERPRISES INC. | |
Well Pad ID: | |
Farm/Lease Name: WYSE & BLOSSER (SWIW #2) | |
License Status: Final Restoration | |
License Date: 2014-01-10 | |
Spud Date: 1996-06-28 | |
Spud Drilling Contractor: BIGARD DRILLING | |
Final Drill Date: 1996-07-04 | |
Well Total Depth: 1337.00 ft | |
Configuration: Vertical | |
Latitude: 41.550000 | |
Longitude: -84.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1996-05-20 | 5175 HEAT CONTROLLER INC GeoDate 5/20/96 |
Oil and Gas | 1996-05-20 | Issued Date 5/20/96 Expired Date 5/20/97 Acres 0020000 Tool Type RTAF Proposed Formation NIAGARAN-MT. SIMON Proposed Depth 01337 Proposed Drill Depth 01337 |
Original Spud | 1996-06-28 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Completed | 1996-07-04 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Reached Total Depth | 1996-07-04 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Completion Report Received | 1996-09-03 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
CO | 1996-10-08 | 5175 HEAT CONTROLLER INC GeoDate 10/8/96 |
Conversion to Injector | 1996-10-08 | |
Salt Water Injection Well | 1996-10-08 | Issued Date 10/8/96 Expired Date 10/8/97 Acres 0000000 Tool Type RTF Proposed Formation NIAGARAN Proposed Depth Proposed Drill Depth |
Storage Well | 1996-10-08 | Issued Date 10/8/96 Expired Date 10/8/97 Acres 0000000 Tool Type RTF Proposed Formation NIAGARAN Proposed Depth Proposed Drill Depth |
Annulus Pressure Monitoring Approved | 1996-10-26 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
First Injection | 1996-11-28 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Change of Owner | 1997-09-02 | Operator changed from 5175, HEAT CONTROLLER INC to 5922, YOHE DON ENTERPRISES INC. |
APP | 2014-01-10 | Proposed Formations:CLINTON, Issued Date:1/10/2014, Expired Date:1/10/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Plugged/Abandoned | 2014-03-14 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Last Compliance Report | 2014-04-01 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Construction Permit Expires | 2016-01-10 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
Record Last Modified | 2017-02-10 | DRILLED AS SWIW CONVERT 10-12-90. WELL P & A ON MARCH 14, 2014 - TET |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-04-28 | 1176 | 1238 | 4 |
2006-09-11 | 1212 | 1222 | 40 |
1176 | 1238 | 4 | |
1212 | 1222 | 40 | |
1176 | 1238 | 4 | |
2006-09-11 | 1228 | 1238 | 40 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 28 | 500 Gal | 0 | TREATED W/500 GAL 28% HCL |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | DON YOHE ENTERPRISES INC. | 4530.00 | 0.00 | 326 |
2012 | DON YOHE ENTERPRISES INC. | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1998 | DON YOHE ENTERPRISES INC. | Brine | 71075 | 326 |
2012 | DON YOHE ENTERPRISES INC. | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1119555747 | 2014-3-12 0:00: | AM | No Violations | |
-1166794598 | 2005-12-27 0:00 | SW | No Violations | |
-1579349966 | 2010-8-19 0:00: | SW | No Violations | |
-1697060252 | 2013-7-17 0:00: | SW | No Violations | |
-1784198531 | 2010-11-17 0:00 | SW | No Violations | |
-1813037877 | 2012-12-13 0:00 | SW | No Violations | |
-1928539068 | 2014-2-21 0:00: | AM | No Violations | |
-473117652 | 2014-9-15 0:00: | FR | No Violations | |
-538424949 | 2011-10-4 0:00: | SW | No Violations | |
-787175536 | 2010-3-4 0:00:0 | SW | No Violations | |
-992992069 | 2013-11-6 0:00: | SW | No Violations | |
0007073514 | 2001-08-23 | Salt Water Injection Well | No Violations | Chk well and storage. Injection pump is not running at this time. OK |
0010873548 | 2001-10-15 | Salt Water Injection Well | No Violations | Chk well and storage. Injection pump not running at this time. Vac/5psi OK |
0013373565 | 2001-12-21 | Salt Water Injection Well | No Violations | Chk well and storage OK. The injection pump is not running at this time. |
0018373614 | 2002-02-04 | Salt Water Injection Well | No Violations | Chk well and storage, OK. |
0027373672 | 2002-06-19 | Salt Water Injection Well | No Violations | Chk well and storage, OK. No fluid in dike at this time. |
0197973634 | 2011-06-28 | Salt Water Injection Well | No Violations | Inspect well. Well shut in. site ok. Conducted 15 minute mini test. Pressured up to 80 psi, no change at 5 minutes and 15 minutes. |
0473117652 | 2014-09-15 | Final Restoration | No Violations | At the time of the inspection all restoration work has been completed and the well location is being farmed. The Pole building with concrete pads, a 300 barrel steel tank, a 100 barrel steel tank, all secondary containment under the steel tanks, all PVC valve boxes, the water well, and the access road to the site from County Road F were left at the request of the landowner. The Landowner Waiver was received and the Final Restoration Passed. |
0538424949 | 2011-10-04 | Salt Water Injection Well | No Violations | Inspect well. Well shut in. |
0722407507 | 2012-06-12 | Salt Water Injection Well | No Violations | Inspect Well. Well is shut in. |
0787175536 | 2010-03-04 | Salt Water Injection Well | No Violations | Well field on temporary shut down until 5/31/10. Called Jim Hoops and left message to remind to test well 1 per month with 200 psi for 15 minutes. Loss of pressure must not exceed 5%. Keep records of testing. |
0992992069 | 2013-11-06 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. The farmer ripped the area immediately arround the builing, tanks, and well. He also ripped up the access road that lead to the well head. |
1046717986 | 2003-03-03 | Salt Water Injection Well | Violations Noted | Gauge for injection pressure has 1/2 inch fitting. Permit requires 1/4 inch fitting to test pressure. Annulus pressure was at 0 (zero). Spoke to operator, Don Yohe by phone. He thought that pressure was being kept on annulus as approved in permit. A 1/4 inch fitting will be added to the injection pressure side. Either keep a positive pressure on the annulus side or else check the annulus pressure once per month with at least 200 psi for at least 15 minutes. Containment dike for tank battery has rubber liner and appears to be in good condition. Sign posted at tank battery. Inspection with Jeff Fry. |
1051113410 | 2003-04-23 | Salt Water Injection Well | Violations Noted | The injection pressure valve still has a 1/2 inch fitting with a gauge that is spiked as previously inspected. The operators valve on the annulus side shows no pressure with the valves open. Could not open the valve on the opposite side of the operators gauge on the annulus side to check pressure to compare with operators gauge. A 1/4 inch fitting must be fitted to the injection pressure side and the valves and plug on the annulus side should be in good working order for pressure testing by the inspector. |
1057157236 | 2003-07-02 | Salt Water Injection Well | No Violations | Operator has installed new gauges on well. Gauges on well attach with 1/4 inch fittings which are compatable with the inspectors gauge. Check of annulus pressure showed 60 psi on both inspector and operator gauge. There was no pressure on the injection side with the inspector and operator gauge. Removal of gauges and shut off valves were in good working condition. Thank you for your cooperation. Notice of Violation is terminated. |
1065550314 | 2003-10-07 | Salt Water Injection Well | No Violations | Checked pressure on well. Pressure on annulus side has dropped from 60 psi to 20 psi. May need to increase pressure on annulus side before it goes to 0 psi. There was no pressure on the injection side. Rubber lined containment pit in good condition. |
1072122390 | 2003-12-18 | Salt Water Injection Well | No Violations | Checked pressure of well. Pressure was 0 on annulus and injection side. Operator Jim Hoops arrived on site after pressure check. He explained that well seems to hold pressure in warm weather but in cold weather pressure will not hold over a few days. He put approximately 40 psi on annulus side during inspection. Pressure held for at least 15 minutes. He said there would be 0 pressure by next morning. Called Jeff Fry. Jeff indicated that there was no violation. |
1077817737 | 2004-02-26 | Salt Water Injection Well | No Violations | There was no pressure on annulus or injection side. This is same situation as last inspection. Temperature has been below freezing. As noted in last inspection, pressure does not hold in these conditions. Will contact operator Jim Hoops to discuss situation. |
1084386225 | 2004-05-12 | Salt Water Injection Well | No Violations | There was approximately 48 pounds of pressure on the annulus side and 0 pounds on the injection side. It appeared as though water was being pumped into the well since the pipes were sweating. Containment dike around tank battery in good condition. |
10873548 | 2001-10-15 0:00 | SW | No Violations | |
1089906610 | 2004-07-15 | Salt Water Injection Well | No Violations | ID sign posted. Containment dike in good condition. Approximately 105 psi on annulus side, 0 psi on injection side |
1095944422 | 2004-09-23 | Salt Water Injection Well | No Violations | Sign posted. Containment dike in good condition. Annulus pressure 78 psi. Injection pressure 0. |
1104933554 | 2005-01-05 | Salt Water Injection Well | No Violations | Sign posted. Dike in good condition. No pressure on annulus or injection side. This is similar to conditions in previous cold weather. Well holds pressure in warm weather. Called operator Jim Hoops who came to well and used air compressor to add presure to annulus side. Annulus pressure was pumped to 60 psi. Pressure held over period of 15 minutes. Discussed monthly testing requirement of 200psi for 15 minutes. Data needs to be recorded on annual report |
1112190316 | 2005-03-30 | Salt Water Injection Well | No Violations | Checked injection well pressure. There was 10 psi on the annulus side and 0 psi on the injection side. Liner for dike around tank battery in good condition. |
1118951466 | 2005-06-16 | Salt Water Injection Well | No Violations | Sign posted. Liner for tank battery in good condition. Pressure on injection side 0 psi and annulus pressure 40 psi. |
1119555747 | 2014-03-12 | Administrative Inspection | No Violations | I received a call from Brad Yohe, Field Supervisor for Yohe Enterprises, who indicating they had set up on the well and cleaned out the debris on top of the cement retainer. They were then able to sting into the retainer and pump water at 1000 psi into the formation indicating the retainer was working correctly. They are planning on cementing the well on 3-14-14. |
1126551428 | 2005-09-12 | Salt Water Injection Well | No Violations | Checked injection well. Approximately 80 psi on annulus side and no pressure on injection side. Drilling contractor Bob Heuer on site pumping water from water well into tank truck. Will be drilling new well on nearby property tomorrow. |
1142883484 | 2006-03-20 | Salt Water Injection Well | No Violations | There was only about a 5 psi difference in pressure between the annulus (30 psi) and injection (25 psi). Called local operator Jim Hoops and left message to check well to be sure there is a continued difference in pressure between the anulus and injection sides. |
1149190809 | 2006-06-01 | Salt Water Injection Well | No Violations | Water could be heard dripping into injection side of well. Pipes were sweaty due to warm outdoor temperature. There was no pressure on the injection side. The annulus side had 30 psi. Liner for storage tank in good condition. Permit sign posted. |
1155584337 | 2006-08-14 | Salt Water Injection Well | No Violations | ID sign posted. Annulus pressure 0 psi, injection pressure 60 psi. Pit for tanks in good condition. |
1166794598 | 2005-12-27 | Salt Water Injection Well | No Violations | Berm and liner for tank battery appear to be in good condition. ID sign posted. Injection pressure 25 psi, annulus pressure 0. |
1168437608 | 2007-01-09 | Salt Water Injection Well | No Violations | ID sign posted. Berm around tank battery in good condition. Injection pressure 0, annulus pressure 25 psi. |
1174399193 | 2008-05-19 | Salt Water Injection Well | No Violations | Spoke to operator Jim Hoops on site. Gauges on injection well are corroded. Injection pressure indicates 20 psi and 0 on annulus. Jim has new gauges on order. |
1175179605 | 2007-03-29 | Salt Water Injection Well | No Violations | Sign posted a wellhead. Containment structure for tank battery in good condition. No pressure on injection side of well and 5 psi on annulus side. |
1185822033 | 2007-07-30 | Salt Water Injection Well | No Violations | Checked injection well. No pressure on injection side and 75 psi on the annulus side. Sign posted. Dike for tank battery in good condition. |
1191517607 | 2007-10-04 | Salt Water Injection Well | No Violations | Sign posted Pit for tank battery in good condition. Annulus pressure 45 psi. No injection pressure. |
1202244945 | 2008-02-05 | Salt Water Injection Well | No Violations | Sign posted at well. Liner in pit for tank battery in good condition. Annulus has 30 psi with 0 psi on injection. Annulus gauge is rusting and should be replaced. |
1218559757 | 2008-08-12 | Salt Water Injection Well | No Violations | Operator has replaced gauges on well. No injection pressure. Annulus pressure 94 psi. Rubber lined pit for tank battery appears to be in good condition. |
1227647127 | 2008-11-25 | Salt Water Injection Well | No Violations | Checked pressure on well. Annulus pressure 25 psi and no injection pressure. Liner for tank battery in good condition. |
1237081036 | 2012-09-19 | Salt Water Injection Well | No Violations | At the time of my inspection the well was shut in and not in operation. There was no power to the meter so no meter reading was available. |
1238589985 | 2009-03-26 | Salt Water Injection Well | No Violations | Checked well. ID sign posted. Annulus pressure 10 psi and 0 injection pressure. Gauges in good condition. |
1247163827 | 2009-07-09 | Salt Water Injection Well | No Violations | Written request submitted to temporarily shut down gas and injection well. There was no pressure on the annular or injection sides of the well. Called Jim Hoops to check what testing is being done on injection well. Left message to call inspector. ID sign posted. Pit liner for storage tanks in good condition. |
1254939897 | 2009-10-07 | Salt Water Injection Well | No Violations | No pressure on the annular or injection side of the well. Spoke to Jim Hoops after last inspection 7/9/09 about requirements to maintain integrity during shutdown time. Operator requested 6 month temporary shutdown in April 2009. Spoke to Jodi Hansen of Yohe Enterprises by phone 10/8/09. They are currently discussing returning well field to operation. She will contact Mike McCormac if additional time for temporary shutdown is needed. Returning to operation will be dependent of natural gas prices. |
1301927908 | 2011-03-29 | Salt Water Injection Well | No Violations | Inspected well. Well shut in. Contacted operator by phone to request test and pressure annulus verify integrity. |
13373565 | 2001-12-21 0:00 | SW | No Violations | |
1365108014 | 2013-04-03 | Salt Water Injection Well | No Violations | At the time of the inspection the well was shut in. |
1392917273 | 2014-02-20 | Administrative Inspection | No Violations | Contacted by Luanne Korte an independent contractor representing Yohe Enterprise. There were communication requirement misunderstandings by the contractor that have been identified and resolved. The operator attempted and failed to plug the well on February 12, 2014. During site activities the operator has set a cement retainer at a depth of 1050 feet. Then attempted to pump fluid below the retainer and failed. The well is believed to have an obstruction in the retainer port hole; the operator intends to use a probe attached to 2 3/8 inch tubing to run a probe on the base of 2 3/8 to circulate this obstruction from the retainer port hole and another attempt to plug out this well will be made. The operator was advised to contact the inspector prior to the phase 2 work currently scheduled for March 3, 2014. |
1394719958 | 2014-03-10 | Plug / Plug Back | No Violations | At the time of the inspection the plugging contractor was setting up to attempt to clean out the debris from above the cement retainer set at 1050 on 2-7-14. This will be done using a probe and 2 3/8 tubing to try to flush out any obstructions above the retainer. An attempt to plug the well on 2-12-14 was unsuccessful due to issues getting to the retainer. |
1394814333 | 2014-03-14 | Plug / Plug Back | No Violations | A cement retainer was set at 1050 inside the 5.5 casing on 2-7-2014 and plugging was attempted on 2-12-14. Debris in the wellbore had fallen down on top of the retainer and did not allow fluids to pass through. On 3-12-14, the debris was flushed clean using 2 3/8 tubing and water was then pumped below the retainer to verify it was functioning correctly. The well was cemented through the 5.5 casing to surface on 3-14-2014. Target Oilfield Tools was the Plugging Contractor. See Plug Report for details. |
1579349966 | 2010-08-19 | Salt Water Injection Well | No Violations | Check well and storage, has positive pressure on the annulus but not enough to measure. |
1618604884 | 2013-01-29 | Salt Water Injection Well | No Violations | At the time of my inspection there were several trucks and other equipment blocking the lane back to the injection facility. The equipment belongs to a construction company building a home across the street. There was nobody available to move the equipment and ther is no other access lane to the well. |
1697060252 | 2013-07-17 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. |
1784198531 | 2010-11-17 | Salt Water Injection Well | No Violations | Has positive pressure on annulus but not enough to measure.
Has identification posted. Liner in diked area is in good condition at this time. Very little fluid in diked area at this time. Site is over grown with weeds, showing signs of none use. |
1785512212 | 2012-02-09 | Salt Water Injection Well | No Violations | Inspect Well. Shut in. |
1813037877 | 2012-12-13 | Salt Water Injection Well | No Violations | At the time of my inspection the well was shut in with 0 psi on both the injection tubing and the annulus. |
18373614 | 2002-2-4 0:00:0 | SW | No Violations | |
1928539068 | 2014-02-21 | Administrative Inspection | No Violations | Brad Yohe of Don Yohe Enterprises Inc. called to report that the Cement retainer installed previously had an obstruction and did not allow circulation of the well. He is has scheduled for March 3, 2014 to run tubing into the well and sting into the cement retainer to attempt to clear the obstruction. Then cement will be ordered for plugging the well. |
197973634 | 2011-6-28 0:00: | SW | No Violations | |
27373672 | 2002-6-19 0:00: | SW | No Violations | |
7073514 | 2001-8-23 0:00: | SW | No Violations | |
722407507 | 2012-6-12 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1046717986 | US-OH-100736 | 2003-03-03 | Violation of injection tubing/fitting requirements | |
1046717986 | US-OH-100737 | 2003-03-03 | Failure to monitor annulus pressure | |
1051113410 | US-OH-100852 | 2003-05-05 | Violation of injection tubing/fitting requirements | |
1051113410 | US-OH-100853 | 2003-05-05 | Failure to monitor annulus pressure |