X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-055-22032

Well Details

Well ID: 34-055-22032
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Russell Township
Operator Name: CUTTER EXPLORATION INC
Well Pad ID:
Farm/Lease Name: OBERLE
License Status: Producing
License Date: 2008-04-11
Spud Date: 2008-07-08
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-07-13
Well Total Depth: 3905.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2008, Expired Date:4/11/2009 6:00:00 AM, Drilling unit acres:24.62, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-07-13
Completion Report Received 2009-02-27
Construction Permit Expires 2009-04-11
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-05-04 3705 3771 25
3705 3771 25
3705 3771 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 75103 Gal 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC 5987.00 78.00 365
2010 CUTTER EXPLORATION INC 5671.00 76.00 365
2011 CUTTER EXPLORATION INC 3180.00 76.00 0
2012 CUTTER EXPLORATION INC 2828.00 80.00 366
2013 CUTTER EXPLORATION INC 3081.00 0.00 365
2014 CUTTER EXPLORATION INC 3784.00 87.00 365
2015 CUTTER EXPLORATION INC 4063.00 80.00 365
2016 CUTTER EXPLORATION INC 3316.00 57.00 365
2017 CUTTER EXPLORATION INC 52.00 5220.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER EXPLORATION INC Brine 431 365
2010 CUTTER EXPLORATION INC Brine 130 365
2011 CUTTER EXPLORATION INC Brine 54
2012 CUTTER EXPLORATION INC Brine 0 366
2013 CUTTER EXPLORATION INC Brine 30 365
2014 CUTTER EXPLORATION INC Brine 0 365
2015 CUTTER EXPLORATION INC Brine 0 365
2016 CUTTER EXPLORATION INC Brine 0 365
2017 CUTTER EXPLORATION INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1435507266 2016-10-26 0:00 UP No Violations
-1811736952 2008-12-29 0:00 PL No Violations
-2131208842 2008-7-8 0:00:0 DD No Violations
-830785203 2013-5-29 0:00: UP No Violations
0015362699 2015-01-13 UrbanProduction Wells No Violations My inspection found no changes since my last inspection. No violations found.
0294338190 2015-08-31 UrbanProduction Wells No Violations My inspection found the company has cleared all of the brush out of inside the tank battery and from around the wellhead. The identification sign has been posted on the fence. There are new locks on all of the fence doors. Scott Miller Construction is going to perform the clean up and repair the broken 3 valve on the load line. The company will contact me when the clean up is complete. I will check the location again on 9/1/2015.
0830785203 2013-05-29 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve is open to a pop off valve that is plumbed into the production tank. The tank battery and well are in good repair and surrounded by a wood fence. The tank battery consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The vent stack on the production tank is plumbed into a 55 gallon charcoal filter. The vent stack is then plumbed up and topped with a spark arrestor. The well does not have a identification sign on it. I spoke with Mark Turpek about getting the sign up. The lease road is in stable condition.
1435507266 2016-10-26 UrbanProduction Wells No Violations I conducted an inspection on this well. The well is equipped with a plunger lift assembly and the valves on the wellhead were open. The well was fenced with a locked man door. The last production records were submitted in 2015. The tank battery consisted of one 100 BBL production tank, one 50 BBL poly brine tank, and a mechanical separator. The chart on the separator showed production and the valves were open. The tanks had plugs on the valves. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery location. The lease access was stable but the gate at the entrance to the access road needs signage to be installed on it. I contacted Mark Turpak from Cutter Exploration with regards to the signage needed at the gate.
1440513018 2015-08-24 UrbanProduction Wells Violations Noted My inspection found the company has had the oil picked up within the past week and the company who removed the oil from the production tank spilled 5 gallons of oil onto the ground inside the tank battery near the load pick up lines. The tank battery is over grown with vegetation. The wooden fence around the tank battery is missing two pickets and does not have a lock on either man door. The fence around the wellhead is missing the lock that was in place on my last inspection. I have contacted Mike Cutter the owner of Cutter Exploration. He stated that Scott Millers Construction will be out on location on 8/25/2015 to clean up the oil and fix the fence and the well tender will be out to take care of the over grown vegetation inside the tank batteries.
1441380177 2015-09-04 Production Wells No Violations On site to check the status of the oil spill clean-up effort. Operator has cleaned up oil stained gravel inside the tank battery dike under the load line valve. Load line valve has been replaced. Operator has cleared brush from the tank battery as requested by the inspector. Inspection of the dike around the tank battery found a cut in the dike east side next to the separator. Tank battery equipment was in good repair. Board on board fence around the tank battery has been repaired and the man door was secured with a lock. Identification sign was posted on the tank battery. Operator stockpiled brush from the battery at the entrance of the site next to the south side of the gate. Leaser road was stable. Wellhead was surrounded with a board on board fence. The man door to the well was locked. There was sledge hammer next to the wellhead along with a discarded lubricating head. Operator was contacted by e-mail to complete the following: Repair cut in dike, remove sledge hammer and lubricating head from site, install chain and lock around the lease road gate, post identification sign on lease road gate, install danger keep out signs or signs with similar wording on the tank battery fence.
1442415813 2015-09-16 UrbanProduction Wells No Violations My inspection found the oil contaminated stone had been removed from the inside of the tank battery. The wooden fence panels have been replaced and locks have been installed. The identification sign has been replaced. I advised the company to install an identification sign on the gate that is updated to meet the urban requirements set in 1501:9-9-05. Locks are still needed to be installed on the lines to unload the tanks. The company has removed the brush and tree saplings from inside the tank battery. A sign that states no open flame, no trespassing, and no smoking needs placed on the tank battery fence and wellhead fence. I have contacted the well tender Mark Turpak about the remaining issues that need to be addressed.
15362699 2015-1-13 0:00: UP No Violations
1793839112 2008-07-07 Drill / Deepen / Reopen No Violations diging pits and making location
1811736952 2008-12-29 Preliminary Restoration No Violations Site has been graded and seeded. Pits are filled. Operator has recently worked over well. Well was leaking at pressure gauge and at a hammer union on the well head. Pipe lines have been rough in. Gate at the entrance to the lease road is up.
2131208842 2008-07-08 Drill / Deepen / Reopen No Violations on site for surface
294338190 2015-8-31 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1440513018 US-OH-112821 2015-11-25 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References