34-075-22210

Well Details

Well ID: 34-075-22210
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Richland Township
Operator Name: DUSTY DRILLING & PRODUCING COR
Well Pad ID:
Farm/Lease Name: GLAUQUE EMERSON
License Status: Producing
License Date: 1979-07-16
Spud Date: 1979-11-19
Spud Drilling Contractor:
Final Drill Date: 1980-03-06
Well Total Depth: 3312.00 ft
Configuration: Vertical
Latitude: 40.460000
Longitude: -82.070000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-07-16 1868 DUSTY DRILL & PRO CORP GeoDate 7/16/79
Oil and Gas 1979-07-16 Issued Date 7/16/79 Expired Date 7/15/80 Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1979-11-19
Completed 1980-03-06
Reached Total Depth 1980-03-06
Construction Permit Expires 1980-07-15
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3164 3178 15
3164 3178 15
3164 3178 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 58000 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 DUSTY DRILLING & PRODUCING COR 0.00 0.00 0
1990 DUSTY DRILLING & PRODUCING COR 0.00 0.00 0
1991 DUSTY DRILLING & PRODUCING COR 0.00 63.00 242
1992 DUSTY DRILLING & PRODUCING COR 0.00 102.00 316
1993 BUCKEYE OIL PRODUCING CO 1410.00 270.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 DUSTY DRILLING & PRODUCING COR Brine 0 0
1990 DUSTY DRILLING & PRODUCING COR Brine 0 0
1991 DUSTY DRILLING & PRODUCING COR Brine 0 242
1992 DUSTY DRILLING & PRODUCING COR Brine 35 316
1993 BUCKEYE OIL PRODUCING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1103028553 2019-10-23 0:00 PW No Violations
-1355163799 2019-6-4 0:00:0 PW No Violations 0.50
1355163799 2019-06-04 Production Wells No Violations This is a follow up inspection to compliance notice 1540307181 issued on 01/09/2019. On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The electric box is on the ground and appears that it is not hooked up to any power supply. The production equipment is made up of two 100 bbl. steel tanks, and a vertical separator. The tanks are not properly identified, and production reporting is not up to date. There has been no change since the last inspection, no new identification sign has been installed.
1540307181 2019-01-07 Production Wells Violations Noted On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, and a vertical separator. The tanks are not properly identified, and production reporting is up to date.
1552653508 2019-03-15 Production Wells No Violations This is a follow up inspection to compliance notice 1540307181 issued on 01/09/2019. On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The electric box is on the ground and appears that it is not hooked up to any power supply. The production equipment is made up of two 100 bbl. steel tanks, and a vertical separator. The tanks are not properly identified, and production reporting is up to date. There has been no change since the last inspection, no new identification sign has been installed. I attempted to place a phone call the company, but the number has been changed with no forwarding number,
1598285902 2020-8-24 0:00: PW No Violations 0.50
348272898 2020-3-27 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1540307181 US-OH-114882 2019-01-11 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References