If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-075-22780 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.52,"lon":-81.9,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Holmes | |
Municipality: Mechanic Township | |
Operator Name: MAC OIL FIELD SERVICE INC | |
Well Pad ID: | |
Farm/Lease Name: YOUNG FM & PAUL E | |
License Status: Producing | |
License Date: 1980-10-16 | |
Spud Date: 1980-12-21 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-12-30 | |
Well Total Depth: 3630.00 ft | |
Configuration: Vertical | |
Latitude: 40.520000 | |
Longitude: -81.900000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-10-16 | 2547 TATUM PETROLEUM CORP GeoDate 10/16/80 |
Oil and Gas | 1980-10-16 | Issued Date 10/16/80 Expired Date 10/16/81 Acres 0000000 Tool Type RTAF Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1980-12-21 | |
Completed | 1980-12-30 | |
Reached Total Depth | 1980-12-30 | |
Construction Permit Expires | 1981-10-16 | |
Change of Owner | 1999-08-02 | Operator changed from 2547, TATUM PETROLEUM CORP to 6507, BROY LIMITED, INC. |
Change of Owner | 2002-04-29 | Operator changed from 6507, BROY LIMITED, INC. to 2547, TATUM PETROLEUM CORP |
Change of Owner | 2005-07-21 | Operator changed from 2547, TATUM PETROLEUM CORP to 1388, NORTH COAST ENERGY INC |
Change of Owner | 2010-05-06 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
Change of Owner | 2016-09-09 | Operator changed from 7578, ENERVEST OPERATING LLC to 5312, MAC OIL FIELD SERVICE INC |
Record Last Modified | 2016-09-09 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3381 | 3441 | 18 |
3381 | 3441 | 18 | |
3381 | 3441 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2400 Bbl | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | TATUM PETROLEUM CORP | 5392.00 | 452.00 | 250 |
1987 | TATUM PETROLEUM CORP | 4396.00 | 359.00 | 250 |
1988 | TATUM PETROLEUM CORP | 3184.00 | 333.00 | 302 |
1989 | TATUM PETROLEUM CORP | 2108.00 | 216.00 | 334 |
1990 | TATUM PETROLEUM CORP | 1472.00 | 222.00 | 339 |
1991 | TATUM PETROLEUM CORP | 1180.00 | 172.00 | 330 |
1992 | TATUM PETROLEUM CORP | 212.00 | 0.00 | 356 |
1993 | TATUM PETROLEUM CORP | 23.00 | 44.00 | 64 |
1994 | TATUM PETROLEUM CORP | 39.00 | 0.00 | 2 |
1995 | TATUM PETROLEUM CORP | 293.00 | 172.00 | 303 |
1996 | TATUM PETROLEUM CORP | 633.00 | 195.00 | 365 |
1997 | TATUM PETROLEUM CORP | 888.00 | 190.00 | 361 |
1998 | TATUM PETROLEUM CORP | 751.00 | 154.00 | 300 |
1999 | BROY LIMITED INC | 213.00 | 0.00 | 0 |
2000 | BROY LIMITED INC | 555.00 | 46.00 | 0 |
2001 | BROY LIMITED INC | 568.00 | 80.00 | 365 |
2002 | BROY LIMITED INC | 153.00 | 0.00 | 365 |
2003 | TATUM PETROLEUM CORP | 1375.00 | 0.00 | 365 |
2004 | TATUM PETROLEUM CORP | 918.00 | 0.00 | 365 |
2005 | TATUM PETROLEUM CORP | 55.00 | 0.00 | 273 |
2006 | EXCO - NORTH COAST ENERGY INC | 537.00 | 94.00 | 365 |
2007 | EXCO - NORTH COAST ENERGY INC | 1029.00 | 225.00 | 365 |
2008 | EXCO - NORTH COAST ENERGY INC | 473.00 | 0.00 | 366 |
2009 | ENERVEST OPERATING LLC | 492.00 | 0.00 | 61 |
2010 | EXCO - NORTH COAST ENERGY INC | 510.00 | 0.00 | 0 |
2011 | ENERVEST OPERATING LLC | 494.00 | 117.00 | 0 |
2012 | ENERVEST OPERATING LLC | 402.00 | 99.00 | 366 |
2013 | ENERVEST OPERATING LLC | 322.00 | 0.00 | 365 |
2014 | ENERVEST OPERATING LLC | 102.00 | 89.00 | 365 |
2015 | ENERVEST OPERATING LLC | 223.00 | 48.00 | 243 |
2016 | ENERVEST OPERATING LLC | 386.00 | 93.00 | 247 |
2017 | MAC OIL FIELD SERVICE INC | 869.00 | 126.00 | 181 |
2018 | MAC OIL FIELD SERVICE INC | 164.00 | 211.00 | 133 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1605076107 | 2016-5-31 0:00: | PW | No Violations | |
-97247924 | 2016-9-29 0:00: | PW | No Violations | |
-998301533 | 2017-11-9 0:00: | PW | No Violations | 0.80 |
0097247924 | 2016-09-29 | Production Wells | No Violations | This well just changed hands and the new operator has moved the tank battery and put a pumping unit on the well. The tank site is properly diked and the unit is set but has no prime mover at this time. |
0998301533 | 2017-11-09 | Production Wells | No Violations | On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, a horizontal separator and a recording gauge. The tanks are properly identified, and the production reporting is up to date. |
1258895417 | 2014-01-16 | Production Wells | No Violations | This is a producing plunger lift well. There were no problems noted at the time of the inspection. |
1558611139 | 2019-05-23 | Production Wells | No Violations | On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 1 1/2-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, a horizontal separator and a recording gauge. The tank is properly identified, and the production reporting is up to date. |
1605076107 | 2016-05-31 | Production Wells | No Violations | This is a producing plunger lift well. There were no problems noted at the time of the inspection. |
584012545 | 2019-9-13 0:00: | PW | No Violations | 0.30 |