34-075-24118

Well Details

Well ID: 34-075-24118
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Richland Township
Operator Name: LARGE JAMES W
Well Pad ID:
Farm/Lease Name: GIAUGEU FRANK
License Status: Producing
License Date: 1983-09-06
Spud Date: 1983-11-25
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1983-12-01
Well Total Depth: 3444.00 ft
Configuration: Vertical
Latitude: 40.470000
Longitude: -82.070000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-09-06 Issued Date 9/6/83 Expired Date 3/4/84 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03444 Proposed Drill Depth 03444
Original Spud 1983-11-25
Completed 1983-12-01
Reached Total Depth 1983-12-01
CO 1983-12-09 1481 OAKMONT OIL & GAS CO GeoDate 9/6/83
Completion Report Received 1983-12-22
Construction Permit Expires 1984-03-04
CO 1991-10-07 627 KENOIL GeoDate 9/6/83
Change of Owner 2004-05-03 Operator changed from 627, KENOIL to 4830, LARGE JAMES W
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3188 3260 0
3188 3260 0
2006-09-11 3203 3255 25
3203 3255 25
3188 3260 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 250 Gal 0 FRAC;2000BBL H2O,ACID
H2O 0 200 Bbl 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 KENOIL LLC 0.00 227.00 365
1993 KENOIL LLC 0.00 151.00 365
1994 KENOIL LLC 0.00 151.00 0
1995 KENOIL LLC 0.00 73.00 0
1996 KENOIL LLC 0.00 154.00 0
1997 KENOIL LLC 0.00 226.00 365
1998 KENOIL LLC 0.00 76.00 365
1999 KENOIL LLC 0.00 149.00 0
2000 KENOIL LLC 233.00 145.00 365
2001 KENOIL LLC 506.00 76.00 365
2002 KENOIL LLC 638.00 76.00 365
2003 KENOIL LLC 416.00 72.00 365
2004 LARGE JAMES W 180.00 0.00 182
2005 LARGE JAMES W 0.00 0.00 365
2006 LARGE JAMES W 216.00 70.00 365
2007 LARGE JAMES W 182.00 6501.00 365
2008 LARGE JAMES W 54.00 0.00 365
2009 LARGE JAMES W 35.00 0.00 365
2010 LARGE JAMES W 15.00 68.00 365
2011 LARGE JAMES W 75.00 20.00 365
2012 LARGE JAMES W 121.00 29.00 366
2013 LARGE JAMES W 520.00 110.00 365
2014 LARGE JAMES W 449.00 28.00 365
2015 LARGE JAMES W 253.00 0.00 365
2016 LARGE JAMES W 95.00 8.00 365
2017 LARGE JAMES W 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 KENOIL LLC Brine 0 365
1993 KENOIL LLC Brine 0 365
1994 KENOIL LLC Brine 0 0
1995 KENOIL LLC Brine 0 0
1996 KENOIL LLC Brine 0 0
1997 KENOIL LLC Brine 0 365
1998 KENOIL LLC Brine 0 365
1999 KENOIL LLC Brine 0
2000 KENOIL LLC Brine 365
2001 KENOIL LLC Brine 0 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 0 365
2005 KENOIL LLC Brine 0 365
2006 LARGE JAMES W Brine 0 365
2007 LARGE JAMES W Brine 0 365
2008 LARGE JAMES W Brine 0 365
2009 LARGE JAMES W Brine 0 365
2010 LARGE JAMES W Brine 0 365
2011 LARGE JAMES W Brine 0 365
2012 LARGE JAMES W Brine 0 366
2013 LARGE JAMES W Brine 0 365
2014 LARGE JAMES W Brine 0 365
2015 LARGE JAMES W Brine 0 365
2016 LARGE JAMES W Brine 0 365
2017 LARGE JAMES W Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1778303705 2020-8-7 0:00:0 PW No Violations 0.30
-574673248 2015-1-5 0:00:0 PW No Violations
-736209345 2013-9-11 0:00: PW No Violations
-741915907 2016-5-19 0:00: PW No Violations
000PL15495 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0116491946 2013-09-17 Production Wells No Violations More Biosorb and hay has been put on the spill but it will all need to be removed when the oil is absorbed.
0574673248 2015-01-05 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0736209345 2013-09-11 Production Wells No Violations Biosorb has been put on the oil and the stuffing box has been repacked and cleaned. The oil saturated hay and the biosorb have not yet been cleaned up.
0741915907 2016-05-19 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
116491946 2013-9-17 0:00: PW No Violations
1193420731 2018-12-17 Production Wells Violations Noted On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a concrete vault, and a vertical separator. The tanks are not properly identified, and production reporting is up to date.
1305137196 2019-10-23 0:00 PW No Violations 0.50
1364866418 2014-05-28 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection. The compliance notice of 9/4/2013 has been satisfied.
1550754342 2019-02-21 Production Wells No Violations This is a follow up inspection of Compliance Notice 1193420731 issued on 12/19/2018. On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a concrete vault, and a vertical separator. The tanks are not properly identified, and production reporting is up to date. A new Identification sign has not been installed yet,
1558544940 2019-05-22 Production Wells No Violations This is a follow up inspection of Compliance Notice 1193420731 issued on 12/19/2018. On the day of my inspection I found, an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods, operated by a pumping unit with an electric motor. The production equipment is made up of two 100 bbl. steel tanks, a concrete vault, and a vertical separator. The tanks are not properly identified, and production reporting is not up to date. 2018 production has not been reported. A new Identification sign has not been installed yet,
1561549469 2019-6-26 0:00: PW No Violations 0.50
1570794992 2019-10-11 0:00 PW No Violations 0.50
1576673148 2019-12-18 0:00 PW No Violations 0.50
1583239580 2020-3-3 0:00:0 PW No Violations 0.50
1595350206 2020-6-10 0:00: PW No Violations 0.30
1600263079 2020-9-16 0:00: PW No Violations 0.80
1636088834 2020-1-22 0:00: PW No Violations 0.30
1716736982 2013-09-04 Production Wells Violations Noted This is a producing pump jack well. There was a 4 x 8 oil spill at the wellhead from a leaking stuffing box. The operator was called for clean-up. There were no other problems noted at the time of the inspection.
686025086 2019-9-5 0:00:0 PW No Violations 0.50
PL15495 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1193420731 US-OH-105109 2018-12-21 9-9-05(A)10 Failure to legibly identify well
1716736982 US-OH-117019 2014-06-05 Well operation causing pollution and contamination

For data sources see[9]

References