If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-075-24375 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.54,"lon":-82.08,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Holmes | |
Municipality: Monroe Township | |
Operator Name: MARAM ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: WYLES HOWARD | |
License Status: Active Injection | |
License Date: 1984-10-12 | |
Spud Date: 1984-07-31 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1984-08-03 | |
Well Total Depth: 3550.00 ft | |
Configuration: Vertical | |
Latitude: 40.540000 | |
Longitude: -82.080000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-07-13 | 149 MORGAN PENNINGTON INC GeoDate 7/13/84 |
Oil and Gas | 1984-07-13 | Issued Date 7/13/84 Expired Date 1/9/85 Acres 0022100 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03550 Proposed Drill Depth 03550 |
Original Spud | 1984-07-31 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Reached Total Depth | 1984-08-03 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
CO | 1984-10-12 | 149 MORGAN PENNINGTON INC GeoDate 10/12/84 |
Conversion to Injector | 1984-10-12 | |
Salt Water Injection Well | 1984-10-12 | Issued Date 10/12/84 Expired Date 4/10/85 Acres 0022100 Tool Type RTA Proposed Formation LOCKPORT Proposed Depth 03150 Proposed Drill Depth 03150 |
Storage Well | 1984-10-12 | Issued Date 10/12/84 Expired Date 4/10/85 Acres 0022100 Tool Type RTA Proposed Formation LOCKPORT Proposed Depth 03150 Proposed Drill Depth 03150 |
Plugged/Abandoned | 1984-11-23 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Plugged Back | 1984-11-24 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Completed | 1984-12-13 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Completion Report Received | 1984-12-24 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Construction Permit Expires | 1985-04-10 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
First Injection | 1985-04-18 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
CO | 1992-08-13 | 65 FRANKLIN GAS & OIL CO INC GeoDate 10/12/84 |
Annulus Pressure Monitoring Approved | 1999-09-30 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Change of Owner | 2000-05-25 | Operator changed from 65, FRANKLIN GAS & OIL CO INC to 5760, S & H WATER SERVICE |
Last Compliance Report | 2015-01-29 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
Change of Owner | 2019-02-26 | Operator changed from 5760, S & H WATER SERVICE to 476, MARAM ENERGY INC |
Record Last Modified | 2019-02-26 | CONVERTED FROM OIL AND GAS TO SWD IN 1984 CONVERT 10-13-84 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-04-28 | 3028 | 3040 | 3 |
2000-04-28 | 3382 | 3426 | 1 |
3028 | 3040 | 3 | |
3382 | 3426 | 1 | |
3028 | 3040 | 3 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1500 Bbl | 35000 | |||
2015-06-11 | ACID | 0 | 1000 Gal | 0 | Producers Service Corporation | Acidized to clean up the formation after a major workover. Pumped 250 gallons of IC Acid then 500 gallons HF acid the the remaining 250 gallons of IC Acid. Displaced to the perforations w/ 750 Gallons of salt water. Shut down for 11 minutes and well went on vacuum. Flushed acid into the form ation with 1500 gallons of saltwater. The well went to vacuum. |
ACID | 15 | 1500 Gal | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1006728674 | 2006-12-1 0:00: | SW | No Violations | 1.50 |
-1006785019 | 2019-2-11 0:00: | SW | No Violations | |
-1026602182 | 2015-6-9 0:00:0 | SW | No Violations | |
-1034392785 | 2013-12-4 0:00: | SW | No Violations | |
-1051167645 | 2009-1-12 0:00: | SW | No Violations | 10.00 |
-1071425512 | 2020-6-8 0:00:0 | SW | No Violations | |
-1082660277 | 2015-4-22 0:00: | SW | No Violations | |
-114754109 | 2012-1-25 0:00: | SW | No Violations | |
-1164811022 | 2016-3-2 0:00:0 | SW | No Violations | |
-1222157434 | 2014-12-15 0:00 | SW | No Violations | |
-1227854823 | 2015-7-29 0:00: | SW | No Violations | |
-1231890130 | 2007-12-6 0:00: | SW | No Violations | 1.50 |
-1236957001 | 2015-6-12 0:00: | SW | No Violations | |
-1260944288 | 2003-9-19 0:00: | SW | No Violations | 1.70 |
-1267286721 | 2011-8-25 0:00: | SW | No Violations | |
-1301554595 | 2013-3-6 0:00:0 | SW | No Violations | |
-1314095041 | 2007-4-26 0:00: | SW | No Violations | 1.50 |
-1329109607 | 2009-1-5 0:00:0 | SW | No Violations | 6.70 |
-1351133399 | 2003-5-21 0:00: | SW | No Violations | 2.20 |
-1409224628 | 2019-11-13 0:00 | SW | No Violations | |
-1413013603 | 2007-9-5 0:00:0 | SW | No Violations | 1.50 |
-1466442682 | 2010-4-1 0:00:0 | SW | No Violations | 2.00 |
-1472668588 | 2017-1-18 0:00: | SW | No Violations | |
-1479175175 | 2016-6-6 0:00:0 | SW | No Violations | |
-1492173423 | 2015-5-14 0:00: | SW | No Violations | |
-1508432749 | 2007-10-1 0:00: | SW | No Violations | 2.50 |
-1535983586 | 2011-12-6 0:00: | SW | No Violations | |
-1551509072 | 2007-9-11 0:00: | SW | No Violations | 3.50 |
-1563647238 | 2015-1-15 0:00: | SW | No Violations | |
-1588259447 | 2013-3-14 0:00: | SW | No Violations | |
-1598809582 | 2015-6-11 0:00: | SW | No Violations | |
-1623752386 | 2015-7-16 0:00: | SW | No Violations | |
-1678126952 | 2019-8-19 0:00: | SW | No Violations | |
-1692468700 | 2008-3-25 0:00: | SW | No Violations | 1.70 |
-1742107538 | 2016-12-2 0:00: | SW | No Violations | |
-1748742869 | 2004-12-27 0:00 | SW | No Violations | 1.50 |
-1762892978 | 2015-6-11 0:00: | SW | No Violations | |
-1783179706 | 2014-10-7 0:00: | SW | No Violations | |
-1790897479 | 2020-2-11 0:00: | SW | No Violations | |
-1865496334 | 2012-11-23 0:00 | SW | No Violations | |
-1868579322 | 2014-5-19 0:00: | SW | No Violations | |
-1972240462 | 2012-4-3 0:00:0 | SW | No Violations | |
-2019182150 | 2005-10-13 0:00 | SW | No Violations | 1.50 |
-2019976507 | 2009-4-13 0:00: | SW | No Violations | 2.00 |
-2072585562 | 2008-7-21 0:00: | SW | No Violations | 2.00 |
-2079765021 | 2013-11-21 0:00 | SW | No Violations | |
-211579399 | 2004-3-18 0:00: | SW | No Violations | 1.50 |
-2143351023 | 2015-4-28 0:00: | SW | No Violations | |
-228844945 | 2018-3-19 0:00: | SW | No Violations | |
-252166915 | 2006-10-10 0:00 | SW | No Violations | 1.50 |
-289444371 | 2015-1-21 0:00: | SW | No Violations | |
-308129983 | 2009-9-23 0:00: | SW | No Violations | 1.50 |
-327546889 | 2008-2-11 0:00: | SW | No Violations | 1.70 |
-335353057 | 2011-6-7 0:00:0 | SW | No Violations | 2.00 |
-338535297 | 2015-1-22 0:00: | SW | No Violations | |
-342165026 | 2007-9-13 0:00: | SW | No Violations | 4.70 |
-376158285 | 2013-6-17 0:00: | SW | No Violations | |
-396432365 | 2016-11-3 0:00: | SW | No Violations | |
-420684657 | 2015-4-16 0:00: | SW | No Violations | |
-444792351 | 2015-9-3 0:00:0 | SW | No Violations | |
-472148466 | 2012-9-5 0:00:0 | SW | No Violations | |
-500611224 | 2018-6-5 0:00:0 | SW | No Violations | |
-51517292 | 2015-3-11 0:00: | SW | No Violations | |
-522435495 | 2008-12-17 0:00 | SW | No Violations | 5.70 |
-555915416 | 2009-1-20 0:00: | SW | No Violations | 4.00 |
-556975241 | 2008-12-12 0:00 | SW | No Violations | 5.00 |
-568393947 | 2006-8-8 0:00:0 | SW | No Violations | 2.00 |
-594977105 | 2009-11-5 0:00: | SW | No Violations | 2.00 |
-599792531 | 2009-1-8 0:00:0 | SW | No Violations | 4.50 |
-645023640 | 2010-8-11 0:00: | SW | No Violations | 2.00 |
-659221206 | 2009-1-9 0:00:0 | SW | No Violations | 3.00 |
-708759415 | 2007-4-26 0:00: | SW | No Violations | 1.50 |
-719734936 | 2007-7-10 0:00: | SW | No Violations | 1.50 |
-786266364 | 2006-2-2 0:00:0 | SW | No Violations | 1.70 |
-823626467 | 2019-4-3 0:00:0 | SW | No Violations | |
-828768665 | 2005-2-10 0:00: | SW | No Violations | 1.50 |
-841319213 | 2019-4-29 0:00: | SW | No Violations | |
-842043041 | 2010-1-22 0:00: | SW | No Violations | 2.00 |
-895627183 | 2007-1-24 0:00: | SW | No Violations | 1.50 |
-916334081 | 2009-3-2 0:00:0 | SW | No Violations | 1.70 |
-944556675 | 2015-10-13 0:00 | SW | No Violations | |
-944765909 | 2010-6-29 0:00: | SW | No Violations | 2.00 |
-946245506 | 2016-3-16 0:00: | SW | No Violations | |
000PL15344 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0010975962 | 2002-01-28 | Salt Water Injection Well | No Violations | Well does not appear to be in operation at this inspection. The barrel counter does show any injection since prior inspection. |
0011375965 | 2002-01-28 | Salt Water Injection Well | No Violations | This well does not appear to be in operation since my last inspection.The barrel counter is not showing any further disposal. |
0018176036 | 2002-03-26 | Salt Water Injection Well | No Violations | Advise operator to re-connect flow meter as it is part of the permit condition. |
0026676084 | 2002-05-15 | Salt Water Injection Well | No Violations | Met pumper on site and found that there were two 300 bbl tanks on site and they planned to store fluid in them for some period of time. I advised that in order to store fluid in the tanks that they would need a lined dike bigenough to hold all of the flu |
0034775933 | 2002-08-01 | Salt Water Injection Well | No Violations | The wellsite needs restored and the two 300 bbl tanks need remove or properly diked to prevent possible leaks or spills. Contact Gary and adivse him that the tanks need properly lined and diked or need removed. |
0038076161 | 2002-08-19 | Salt Water Injection Well | No Violations | The two 300 bbls have been removed and the area has some grading but still needs seeding . |
0042676192 | 2002-09-12 | Salt Water Injection Well | No Violations | Operator has brought back a 300 bbl tank after I had him remove two others just last month . Tank is empty and not hooked up to the pump as it was before . |
0042876194 | 2002-09-12 | Salt Water Injection Well | No Violations | Tnk remains on site , but tank is empty and not hooked up to the pump as before. |
0043176197 | 2002-09-11 | Salt Water Injection Well | No Violations | During my inspection I discovered that another 300 bbl tank has been dropped off at location . I had the operator remove two 300 bbl tanks just days ago . The tank appears to be empty and not connected to the pump as it was the last time . |
0043676201 | 2002-09-16 | Salt Water Injection Well | No Violations | Arrive on site to find that one 300 bbl tank remains on site and that it is also empty. The tank is not connected to the pump at this inspection .Also contact Dave Hodges on wellsite information . |
0043776202 | 2002-09-17 | Salt Water Injection Well | No Violations | Check wellsite today and found that 300 bbl tank has not been filled or removed ? Contact Gary and advise that tank needs removed and wellsite needs graded and seeded before winter sets in .He advised that he would remove tank as soon as somebody can haul |
0045476216 | 2002-10-15 | Salt Water Injection Well | No Violations | Area around well has been graded and seeded with good vegetation being established . |
0051517292 | 2015-03-11 | Salt Water Injection Well | No Violations | |
0095793063 | 2015-04-29 | Salt Water Injection Well | No Violations | Workover in progress. They tested the casing t at 2347 to 715 psig for 15 minutes. The pressure dropped off to 680 psig. This is right at the 5% limit of pressure loss. Continuing to drill cement. |
0111893205 | 2017-05-15 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017. FORM 204 RECD 8/14/2017 |
0114754109 | 2012-01-25 | Salt Water Injection Well | No Violations | Well on vacuum. Annulus 230 psig. No problems noted at well or tank facility. Well was not in operation at time of inspection. |
0126260358 | 2009-02-09 | Salt Water Injection Well | No Violations | While I was in Columbus for State wide meeting Omega did another squeeze on 4 inch casing. Set 500 ft cement plug from 1900 ft to 1400 ft and used 1500 psi to push it . |
0140202067 | 2010-06-07 | Preliminary Restoration | Violations Noted | During my inspection of the site I found that the restoration for the last repair of well has not been completed. The site has been graded but never re- seeded. That needs to be done now. I had ask during my last several inspections to have the valve on the annulus repaired or replaced. It can not be opened safely and may not close if I force it open. At the last two inspections the valve has not been replaced. |
0176591686 | 2013-09-23 | Salt Water Injection Well | No Violations | Injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection. |
0177631121 | 2013-08-27 | Salt Water Injection Well | No Violations | The tubing pressure was 4 psig. The annulus pressure was 195 psig. There were no problems noted at the time of the inspection. |
0179960665 | 2015-05-05 | Salt Water Injection Well | No Violations | Tested the well to 700 psig and the well dropped to 680 psig in 15 minutes. Drilling cement. |
0183454666 | 2010-04-28 | Salt Water Injection Well | No Violations | Restoration of this site will need done. |
0211579399 | 2004-03-18 | Salt Water Injection Well | No Violations | Inject ion pressure 0 Annulus pressure-10 the flow meter is broken or has been reset again. It remains on -0- |
0228844945 | 2018-03-19 | Salt Water Injection Well | Violations Noted | On site to witness running of tubing and packer in well and witness MIT test, packer set@2972 set in tension and Petroset performed pressure test on said well this resolves previous compliance notice for well not passing required testing. Currently well has passed required testing resolving previous notice issued. |
0242168301 | 2015-01-15 | Salt Water Injection Well | Violations Noted | This is a salt water injection well. The tubing was on vacuum. The annulus was also on vacuum. The tubing and annulus appear to be equalized. The operator was called to shut the well in until the problem can be identified and he will comply. He was asked to contact this inspector when a rig is on the well. UIC Inspector Dave Ball was notified of the situation and he contacted Columbus for a suspension order. |
0243432746 | 2012-07-05 | Salt Water Injection Well | No Violations | There were no problems noted at the facility at the time of the inspection. The tubing was on vacuum and the annulus had 250 pounds of pressure on it. |
0252166915 | 2006-10-10 | Salt Water Injection Well | No Violations | No clean up done at this inspection .Met Gary and advised that he should Lime area where low vegetation cover is and turn over for winter .Seed in Spring. Advise repair flowmeter . |
0289444371 | 2015-01-21 | Salt Water Injection Well | No Violations | The rig moved on and rigged up but was unable to pull the tubing because of the lack of threads on the top joint of tubing. A welder was brought out to fix that problem. They picked up on the tubing but were not able to unseat the packer because they didnt have enough pup joints on location to un-jay it. Will pick up some more tubing and regroup in the morning |
0291547947 | 2007-10-04 | Salt Water Injection Well | No Violations | Met with construction crew and collect photos of dike and tanks for Columbus.26 yards long 13 wide 3 1/2 ft. high.Well remains shut in because there are no thanks hooked up . |
0306734524 | 2008-09-09 | Salt Water Injection Well | Violations Noted | Issue NOV to Gary today for unloading pad.The front pad has sank and the leaking brine collects on the pad and then runs off to the right of the pad.It has started a small brine kill area 5 x7 ft .Pad needs to have dirt ,cement or some other material to contain brine on the pad and make it run into the vault at the back of the pad. |
0308129983 | 2009-09-23 | Salt Water Injection Well | No Violations | Check on well after Gary called and said he was having problem with the injection side . He feels he needs to do another acid job which is where the problems from last year started . |
0327546889 | 2008-02-11 | Salt Water Injection Well | No Violations | Just had all of the dike and lines re-done on this site ,wanted to check after some freezing and see if the tanks have moved. |
0335353057 | 2011-06-07 | Salt Water Injection Well | Violations Noted | Annulus valve can not be opened and or closed. There has been a blow out of oil and brine over area of 20 x 3 ft. Most likely from somebody opening the valve and not being able to close it. Contact Gsry and advise that somebody blew oil and brine out on ground which needs cleaned up and repair annulus valve. Advise place 2nd valve on annulus and just leave bad valve open so there are no more leaks. |
0338535297 | 2015-01-22 | Salt Water Injection Well | No Violations | Bishop Well Service released packer and then they pulled it from well and they found defected tubing and they plan on starting new packer and tubing in hole on 1/26/15. |
0342165026 | 2007-09-13 | Salt Water Injection Well | No Violations | Met crew today for pictures and meeting with Gary Staggs .W/o on Gary to arrive for tank info and questions on cement vault,liner ,and dike. |
0376158285 | 2013-06-17 | Salt Water Injection Well | No Violations | The tubing had 10 psig and the annulus had 70 psig. There were no problems noted at the time of the inspection. |
0390968380 | 2015-04-23 | Salt Water Injection Well | No Violations | They tested the casing the first thing this morning and it held 700 psig. They have drilled two kellys down and are circulating bottoms up. They hope to drill down 3 more joints this date. |
0396432365 | 2016-11-03 | Salt Water Injection Well | No Violations | The unloading facility had no issues and the ID was visible and good repair. The injection pump was not running at the time of the inspection. The tubing was static and the annulus had 4 psig on it. There were no trucks unloading at the time of the inspection. |
0420684657 | 2015-04-16 | Salt Water Injection Well | No Violations | The operator has decided to try to save the well. A bond log was run from 3100 to 1400. Several areas of suspect bond were identified and one area of free pipe. A bridge plug was set at 2850. The plan is to run tubing and tag the bridge plug and to spot cement in the casing from 2850 to 1500. The tubing will be pulled out of the cement and an attempt will be made to squeeze the cement into any place that will take it. The cement will sit over the weekend and they will start drilling it out on Monday. |
0444792351 | 2015-09-03 | Salt Water Injection Well | No Violations | The annulus is at zero psig and the Tubing is on vacuum. There were no problems noted at the time of the inspection. |
0457280984 | 2007-09-05 | Salt Water Injection Well | No Violations | Pull the remainder of tanks today and begin excavading the old dike and soil below tanks. |
0458717631 | 2015-04-24 | Salt Water Injection Well | No Violations | Workover in progress. At 1900 and tested the casing to 740 psig for 15 minutes. Dropped to 710 psig. Acceptable. Drilled out more cememt. |
0466490831 | 2010-06-07 | Preliminary Restoration | No Violations | FOLLOW UP TO NOV # 140202067 During my inspection of the site I found that the restoration for the last repair of well has not been completed. The site has been graded but never re- seeded. That needs to be done now. I had ask during my last several inspections to have the valve on the annulus repaired or replaced. It can not be opened safely and may not close if I force it open. At the last two inspections the valve has not been replaced. |
0472148466 | 2012-09-05 | Salt Water Injection Well | No Violations | Inspected site along with Todd Miller and inspection revealed that injection pump wad not in operation during our inspection and it was also noted that company owned vacuum truck was unloading at site during our inspection. |
0473311371 | 2016-05-09 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Barrel counter has not changed in the last year I assume it is broke and in need of repair. |
0492469382 | 2016-01-28 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection. |
0500611224 | 2018-06-05 | Salt Water Injection Well | No Violations | Inspection today revealed that one storage tank has been recently changed out and it appeared that owner is hauling water into well there was tracks going to unloading pad indicating that a truck was recently on site. |
0522435495 | 2008-12-17 | Salt Water Injection Well | No Violations | Run in hole with another rebuilt R-4 packer to 2945 ft.Pumped 40 bbl freshwater with 4 gallons of Halliburton anhib and 1 st test failed, pull up 6 ft and 2nd test failed .Pull up 10 more and test failed.Pull up again after switching out pups and test again at 2906 ft. . Test failed again -Drop standing valve and found hole in the new string of tubing. |
0555915416 | 2009-01-20 | Salt Water Injection Well | No Violations | Arrive to test casing again .W/O Water truck ,then load hole and pressure up on 4 inch,Test failed . 2nd test failed and 3 rd test failed.Could get pressure up to 700 psi but it would not hold.Advise run packer in hole in 500 ft stages then down to 100 ft and so on until hole was found then do another squeeze. |
0556975241 | 2008-12-12 | Salt Water Injection Well | No Violations | Arrive today to witness rebuilt Halliburton R-4 Packer go in hole. It has no tailpipe but does have a standing valve on top of the packer.Had conflicting info from the operator and had to wait until Tom Tomastick confirmed that the well was cemented to surface and not just 300 ft. above the zone.Run in with new string of 2 3/8 tubing. |
0568393947 | 2006-08-08 | Salt Water Injection Well | Violations Noted | Arrive today for inspection and found that the tanks have been run over inside the dike .It appears that most of the free oil has been cleaned up and that some brine may have soaked thru the dike .There is an area behind the dike that needs to have the contaminated soil removed and clean fill put back down .Then this same area will need to be graded and seeded .The flow meter has been off line and needs to be repaired or replace as part of the permit condition . |
0575178217 | 2017-05-03 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation and currently the well appears that is not being used much at this time. |
0593568587 | 2009-05-26 | Salt Water Injection Well | No Violations | Restoration of wellsite needs done. |
0594977105 | 2009-11-05 | Salt Water Injection Well | No Violations | |
0599792531 | 2009-01-08 | Salt Water Injection Well | No Violations | Bishop Well Service has tagged top of cement at 1800 ft. Next drill out cement and pump up casing using the mud pump and could only get 500 psi - would hold at 200 psi. but would not go above 500 psi |
0618736531 | 2007-11-14 | Salt Water Injection Well | No Violations | |
0618764357 | 2005-10-20 | Salt Water Injection Well | Violations Noted | FAILURE TO SUBMIT ANNUAL SALTWATER INJECTION WELL REPORTS |
0625688573 | 2005-10-20 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # 618764357 FAILURE TO SUBMIT ANNUAL SALTWATER INJECTION WELL REPORTS |
0634946996 | 2011-03-08 | Salt Water Injection Well | No Violations | |
0645023640 | 2010-08-11 | Salt Water Injection Well | No Violations | The valves have been replaced and the area was graded and seeded. The seed did not take because it was too hot and dry so it will need to be redone. Contact Gary and advise , he is going to wait until the fall which is fine. |
0657964960 | 2011-01-05 | Salt Water Injection Well | No Violations | Restoration re-done again - still no vegetation cover and cannot be passed until spring 2011. Annular valve was frozen & pressure could not be verified. |
0659221206 | 2009-01-09 | Salt Water Injection Well | No Violations | Arrive for bond log which was scheduled for today but only to find out that it has been cancelled and is now scheduled for Monday. |
0708759415 | 2007-04-26 | Salt Water Injection Well | Violations Noted | Barrel counter has been broken for several inspections and needs repaired or replaced . |
0719734936 | 2007-07-10 | Salt Water Injection Well | No Violations | The barrel counter is not working . |
0727477714 | 2018-02-01 | Salt Water Injection Well | Violations Noted | Inspection revealed that well is still incapable of injection in its present state of repair. |
0786266364 | 2006-02-02 | Salt Water Injection Well | No Violations | |
0816083746 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. |
0819410159 | 2018-05-03 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. |
0823626467 | 2019-04-03 | Salt Water Injection Well | No Violations | Well not in operation during our inspection and it was noted that new owner was on site replacing sump pump to unloading pad vault.
Told new owner that pressure needs to be applied to annulus of tubing ASAP. To ensure the division of casing integrity. |
0825361710 | 2007-09-27 | Salt Water Injection Well | No Violations | Met with crew on tanks and vaults which are being installed.Go over liner ,vault set up. |
0828768665 | 2005-02-10 | Salt Water Injection Well | Violations Noted | Found that flowmeter is still not working.Contact Gary and advise on meter and gave him 1 week to fix it or I would request a Chiefs order to shut him down.Also issue notice for burning the filters on the ground .Advise him to store in covered container or remove them to a landfill. |
0830457375 | 2015-01-22 | Salt Water Injection Well | No Violations | The packer wsas unjayed and the tubing and packer were pulled form the well. There were holes in 14 joints. New tubing has been ordered and a new packer and tubing will be run on 1/26/15. |
0841319213 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
0842043041 | 2010-01-22 | Salt Water Injection Well | No Violations | Restoration of well site needs to be done in the spring.More grading and seeding with mulch. |
0845213527 | 2002-12-19 | Solution Mining Project | No Violations | Tanks are removed and area has been graded and seeded . |
0849760304 | 2015-01-28 | Salt Water Injection Well | No Violations | They were unable to get all the tubing in the hole as they were pushing sludge off the casing ahead of the packer. They had pulled the tubing and packer back out yesterday and have run in open ended and are circulating the sludge out of the hole. The plan is to run the packer and tubing back in on the morrow. |
0866172159 | 2018-07-18 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation and it was noted that well is in operation and it was noted that evidence of recent activity on unloading pad and entrance gate was open upon our arrival on site. |
0895627183 | 2007-01-24 | Salt Water Injection Well | Violations Noted | The flowmeter needs to be repaired or replaced .The flowmeter is part of the permit operating conditions . |
0898303326 | 2017-08-01 | Salt Water Injection Well | No Violations | Inspection revealed that well is not being used much at this time. |
0906071943 | 2007-09-13 | Salt Water Injection Well | No Violations | Arrive today for meeting with Gary and clean up crew and also to take pictures for file. |
0916334081 | 2009-03-02 | Salt Water Injection Well | No Violations | Valves frozen on annulus . |
0944556675 | 2015-10-13 | Salt Water Injection Well | No Violations | Tubing on Vacuum. Annulus 0 psig. Pit has been closed and location is back to original grade after the workover. Not much grass growth so far. |
0944765909 | 2010-06-29 | Salt Water Injection Well | No Violations | Valves have been replace on the annulus and area has been graded and mulched. |
0946245506 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED 2/1/2017 |
0949342589 | 2015-05-04 | Salt Water Injection Well | No Violations | Workover in progress. Tested the well to 710 psig and it dropped back to 690 psig in 15 minutes. Drilling cement. |
0985608243 | 2018-08-29 | Salt Water Injection Well | No Violations | No activity at the site today and I contacted owner and requested that positive pressure needs to be applied to annulus of tubing ASAP. |
1006728674 | 2006-12-01 | Salt Water Injection Well | No Violations | The barrel counter has been broken again and needs repaired .Also the clean up has been started and will finish in the spring . |
1006785019 | 2019-02-11 | Salt Water Injection Well | Violations Noted | The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. |
1024107704 | 2008-12-16 | Salt Water Injection Well | No Violations | Arrive to find the scraper in the hole on 2 3/8 tubing .Bishop Well service has most of the zone cleaned and should be able to set packer and test .After waiting for scraper to finish we found out that the pumptruck for the pressure test could not make it and the test was then set for Weds. At 8:30 |
1026602182 | 2015-06-09 | Salt Water Injection Well | No Violations | Workover in progress. The rig ran another joint below 3040 and tagged more cement at 3050. They commenced drilling and drilled that joint down and drilled ~ 23 of cement. They pulled the tubing out of the hole and filled the 2-7/8 to the surface with water in preparation to run the bond log. Appalachian Well service ran the bond log and found the top of the cement on the outside of the 2-7/8 to be at 1130. The bond was good from 3010 to 1130. Appalachian was rigged down and an injection test was done on the perforations. The perforations took fluid and the rate was bumped up and the pressure stayed at ~ 180 psig. An MC acid job is scheduled for 6/11/15 to clean up the perforations. |
1028238988 | 2007-08-14 | Salt Water Injection Well | Violations Noted | Found that the Barrel counter is still not working.There has been a spill inside the dike again and the area outside the dike has a kill area.The filters are in bags but the bags are open and rain fills them and they are running over.The whole area is a mess.Contact Gary and issue NOV for clean up ,barrel counter and dike repair . |
1034392785 | 2013-12-04 | Salt Water Injection Well | No Violations | Injection pump not in operation today and it was noted that unloading pad has been cleaned since my last inspection. |
1051167645 | 2009-01-12 | Salt Water Injection Well | No Violations | Travel to witness cement bond log and neutron log .Had to wait because log truck was 3 hours late.Ran cement bond log and found possible hole at 1720 ft. Then wait on cement and water trucks to arrive to pump dummy plug down.Displaced it to 1835 ft. and verified with wireline.Next mixed 55 sks and displace with wireline to 1700 ft .Operator said he wanted to let plug set up for 2 days before he drilled it out. |
1082483738 | 2004-03-18 | Salt Water Injection Well | No Violations | Injecton Pressure-0 Annulus Pressure-10- barrel counter on -0- |
1082660277 | 2015-04-22 | Salt Water Injection Well | No Violations | The casing tested to 700 psig again this morning. Drilling cement. They should be to ~1800 by this evening. |
1086011828 | 2008-01-29 | Salt Water Injection Well | No Violations | |
10975962 | 2002-1-28 0:00: | SW | No Violations | 1.20 |
1106562091 | 2008-08-07 | Salt Water Injection Well | No Violations | Tanks removed and area has been graded and seeded.Violation has been corrected. |
111893205 | 2017-5-15 0:00: | SW | No Violations | |
11375965 | 2002-1-28 0:00: | SW | No Violations | 1.20 |
1144170350 | 2017-06-20 | Salt Water Injection Well | No Violations | Inspection revealed there was no activity at the site today. |
1164811022 | 2016-03-02 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd, & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. fees and reports received 2/1/2017 |
1175863575 | 2007-03-07 | Salt Water Injection Well | No Violations | Barrel counter is broken and needs repaired or replaced .Talk with Gary and Advise of repair . |
1178894869 | 2015-04-21 | Salt Water Injection Well | No Violations | Drilled down 6 joints of tubing. The casing was tested the first thing this morning and it held 700 psig. Drilling cement. |
1189686764 | 2014-08-22 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that housekeeping is needed in unloading pad area. |
1191200130 | 2007-09-27 | Salt Water Injection Well | No Violations | Met crew on tanks and rework of tank battery .Dike is mostly repaired and liner is in place and tanks are being connected and vault is in and will be covered so that it will not float. |
1201285810 | 2007-09-11 | Salt Water Injection Well | No Violations | Tanks are out dike is being rebuilt on 3 sides and topsoil and clay are inside dike for buffer. |
1210i26571 | 2002-03-27 | Salt Water Injection Well | No Violations | Snow cover. Need 1/4 working valve on injection tubing. Accompanied by Tom Tomastik, and Dave Hodges. |
1210i2657182 | 2002-3-27 0:00: | SW | No Violations | |
1222157434 | 2014-12-15 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that annular pressure has fallen to zero and I contacted owner and requested that they have positive pressure applied to annulus of tubing ASAP.
Note: Barrel counter is in need of repair. |
1227854823 | 2015-07-29 | Salt Water Injection Well | No Violations | The pits from the workover have been emptied and filled in. The location has been put back to grade. The annulus had 205 psig and the tubing was on vacuum. There were no problems noted at the time of the inspection. |
1231890130 | 2007-12-06 | Salt Water Injection Well | No Violations | Dike has been repaired and new liner in place with cement vault for drain on the unloading pad inside the lined dike. |
1233076127 | 2008-11-14 | Salt Water Injection Well | No Violations | Well not on vaccum today. |
1235048499 | 2009-02-17 | Salt Water Injection Well | No Violations | Arrive today to test new tubing and packer.Operator had new string of tubing and rebuilt Halliburton R4 Packer at 2880ft.Omega pumped 10 bbl of fresh water ahead and then mixed 3.5 gallons of anhib with 35 bbls of fresh water.Displace 45 bbls total and set packer on 12,000 tension. Pumped up annulus to 700 P.SI. And began 15 minute test.Lost 18 P.S.I. Over 15 minute test.Test passed.Contact Tom Tomastik and advise .He will remove Chiefs order and well can now go back into operation. |
1236957001 | 2015-06-12 | Salt Water Injection Well | No Violations | On location to witness the running of the 1-1/2 tubing and the 2-7/8 x 1-1/2 Parmaco packer. The well was on vacuum. The rig ran 90 joints of 1-1/2 tubing to 2976.5 (35.5 above the top perforation) The well was shut in because a pump truck to do the MIT was not available. |
1238759097 | 2009-02-05 | Salt Water Injection Well | No Violations | Found that they have 30 ft of cement left to drill out. Next wait on rig to circulate cement out .Then wait on water truck and swap out well head to be able to test .Pressure up to 700 psi and test failed but only slightly.It took 10 minutes to fail.Air in system and tried 3 tests all the same.Next had meeting with Gary Staggs and Dave Bishop on how to proceed. |
1260944288 | 2003-09-19 | Salt Water Injection Well | No Violations | |
1260987968 | 2010-09-13 | Salt Water Injection Well | No Violations | Restoration has just been redone , check again to see if vegetation has been established. |
1261872753 | 2015-04-20 | Salt Water Injection Well | No Violations | Ran the tubing with a bit to bottom and tagged the top of the cement at 1440. Rigging up the pump and power swivel. |
126260358 | 2009-2-9 0:00:0 | SW | No Violations | 0.00 |
1263215892 | 2007-08-14 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1028238988 Found that the Barrel counter is still not working.There has been a spill inside the dike again and the area outside the dike has a kill area.The filters are in bags but the bags are open and rain fills them and they are run |
1264712063 | 2018-05-24 | Salt Water Injection Well | No Violations | Inspection revealed that owner is currently swapping out one 210 barrel storage tank at site old tank has been cleaned and removed from dike and new tank has been put in place workers are currently plumbing up new tank. |
1265416388 | 2014-10-22 | Salt Water Injection Well | No Violations | There were no problems noted at the time of the inspection. |
1267286721 | 2011-08-25 | Salt Water Injection Well | No Violations | No problems noted. Could not get pressures as there are no 1/4 fittings on annulus and the one on the tubing cant be opened. The well was not in operation. |
1285833331 | 2011-05-13 | Salt Water Injection Well | No Violations | Restoration is ok 95 % green. Should get even better as summer moves along. Also well on vacuum and annulus just on 0 not vacuum. |
1294671538 | 2010-10-18 | Salt Water Injection Well | No Violations | Restoration of site has failed again and contact Gary and advise that site needs re- re- done. |
1301554595 | 2013-03-06 | Salt Water Injection Well | No Violations | The compliance notice of 6/7/2010 has been satisfied. |
1307010874 | 2016-07-07 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and it was noted that owner is currently trying to establish vegetation in area of old pit they had when they reworked well last year. |
1313149662 | 2011-04-12 | Salt Water Injection Well | No Violations | Restoration is showing a nice green up . Site may need more time to fully establish vegetaion.Will ok restoration now and continue to monitor site . |
1314095041 | 2007-04-26 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -708759415 Barrel counter has been broken for several inspections and needs repaired or replaced . |
1315731438 | 2006-03-20 | Salt Water Injection Well | No Violations | The flowmeter has been reset to O and should not be reset . |
1316777143 | 2011-06-30 | Salt Water Injection Well | No Violations | Could not get annulus valve open - still stuck. No repairs completed and no additional valve added. Clean up of oil and brine from prior blow out still not removed. Advise new Inspector Miller of my follow up and the problems which remain. |
1317214872 | 2011-09-28 | Salt Water Injection Well | No Violations | 1/4 valves installed on both tubing and annulus as requested. Annulus pressure 40 psig. Tubing on vacuum. No problems noted at time of inspection. |
1319471598 | 2015-05-06 | Salt Water Injection Well | No Violations | Workover in Progress. No activity today. |
1329109607 | 2009-01-05 | Salt Water Injection Well | No Violations | There is a wire line bridge set at 2708 ft . Arrive to test plug , w/o equipment - Bishop well is moving service rig in today.Got all of the equipment in place and found that the wellhead needed to be removed and had to wait on change over to hook up for this test. Pressure up to 500 P.S.I. With 2.5 barrels per minute and ran out of water. Next had to wait on water and cement trucks to squeeze hole in casing.Pump dummy plug and found hole and then ran in with tubing to 1850 ft. and set 50 sacks class A - followed with wire line to check depth.Stop plug at 1800 ft. |
1351133399 | 2003-05-21 | Salt Water Injection Well | No Violations | Met Gary Staggs on location and went over clean up of line leak . Also showed him small area behind tanks that has low vegetation from previous leak inside dike . Gary has lines repaired and will excavate soil and remove as soon as it quits raining . Test new line to 750 psi for 15 minutes and test passed with 0 leak off . |
1386497919 | 2003-05-07 | Salt Water Injection Well | No Violations | Check well today and found that the injection line from the pump to the well has a leak in it . The area is brine saturated and has also scalded the vegetation in a 12 x 12 circle . Contact Gary and adise on leak . He said that he would shut it in and replace the line along with excavating the saturated soil . He is to contact me before he places well back in operation for a test on new line . |
1392153756 | 2009-09-02 | Salt Water Injection Well | No Violations | Well not on vacuum today. Well location still needs more restoration done. Looks like some grading has been done but not enough . Needs seeded |
140202067 | 2010-6-7 0:00:0 | PL | No Violations | 2.00 |
1413013603 | 2007-09-05 | Salt Water Injection Well | No Violations | Clean up continues today with all of the tanks now being pulled and the dike area being excavated and the contaminated soil is being removed. |
1417072940 | 2015-06-08 | Salt Water Injection Well | No Violations | Workover in progress. The rig drilled the cement out of the 2-7/8 tubing and circulated to ~3040. They pulled back up into the 2-7/8 and shut down for the night. A bond log is scheduled for 6/9/15. |
1419936134 | 2013-09-23 | Salt Water Injection Well | No Violations | The annulus had 40 psig, the tubing was on vacuum. There were no problems noted at the time of the inspection. |
1421879341 | 2015-01-21 | Salt Water Injection Well | No Violations | Inspection revealed that Bishop Well Service has moved rig in on site and they are preparing to pull packer and tubing from well once they repair top joint of tubing by rethreading pipe and replacing collar. |
1422392882 | 2015-01-26 | Salt Water Injection Well | No Violations | On site to witness tubing and packer run into well and once packer is set flush annulus of tubing with fresh water and inhibitor and then pressure test well,
Note: Pretest indicated good pressures and then packer was released and we flushed annulus with fresh water and inhibitor and reset packer @2963 but in process the formation became plugged up with paraffin and heavy oil residue so then decision was made to release packer and clean up wellbore and they will possibly want to rerun packer later this week. |
1422533298 | 2015-01-26 | Salt Water Injection Well | No Violations | Rhe rig is running the packer and tubing back in the hole. They will pump in the injhibited fresh water set the packer and do a mechanical integrity test. UIC inspector Dave Ball is on location. |
1422572029 | 2015-01-29 | Salt Water Injection Well | No Violations | On site along with two UIC staff members from central office to witness tubing and packer run into well and Omega Cementing pumped 32 bbl of fresh water and four gallon of inhibitor and packer was set at 2961 set in tension 12 K over string weight and we tested at 750 psi with a 10lb. pressure loss (TEST PASSED). |
1429093279 | 2015-04-14 | Salt Water Injection Well | No Violations | Moved a rig on and rigged up. Both the annulus and the tubing were on vacuum. The packer was still set. Unjayed the packer and pulled the tubing. There were no marks or obvious grooves in the packer element. Replaced the packer element and ran it and the tubing back in the well to 2932 which is 96 above the top perforation. Shut down for the day as no pump truck was available for the pressure test. |
1429180620 | 2015-04-15 | Salt Water Injection Well | No Violations | Petroset displaced 35 bbls of fresh water with 3.5 gallons of Halliburton Anhib into the annulus. The packer was set in tension at 14,000 over string weight. The annulus was pressure tested to 730 psig and did not hold. Three subsequent tests failed as well. One joint was removed from the well and the packer was reset and the annulus tested but with the same results, no test. A second joint was removed with the same results. A third joint was removed and it also did not test. The rig pulled the tubing and tested at ~1900 with no test but finally got a test at 1771. The balance of the tubing was pulled from the well. The rig shut down for the night. The operator will have a plan by morning. |
1429210857 | 2015-04-15 | Salt Water Injection Well | No Violations | Inspection revealed that well has equalized and Bishop Well Service has rig on hole trying to determine problem they released packer and removed from well and rebuilt it and ran back in hole and set it several times trying to determine where possible casing failure is located first good pressure test was at 1771 so decision was made to attempt to squeeze cement in lower section of well later this week if they can get all of the proper contractors on board. |
1429528086 | 2015-04-17 | Salt Water Injection Well | No Violations | The tubing was run and tagged the bridge plug at 2836 and pulled up to 2822. Petroset spotted two 55 sack plugs from 2822 to 1422. The tubing was pulled out of the cement. Any excess cement was reversed out of the well/tubing and the well was pressured up to 1000 psig. It dropped back to 900 psig and was bumped to 1200 psig for ~10 minutes with very little drop off. The pressure was released and the well shut in until Monday when drill out will commence. |
1430493285 | 2015-04-30 | Salt Water Injection Well | No Violations | Workover in progress. At 2508 this morning and pressure tested the well to 750 psig. The pressure dropeed to 590 psig in 15 minutes. This is outside of the parameters of the test. The operator decided to squeeze cement again. Petroset spotted 35 sacks of cement from 2508 to 2168. The rig pulled the tubing out of the cement, reverse circulated and pressured up on the well to 750 psig. It dropped back 30-40 psig. After 10 minutes, the pressure was bled off to 200 psig and the well was shut in until Monday when drilling will commence. |
1431083337 | 2015-05-08 | Salt Water Injection Well | No Violations | Workover in progress. The rig is down until 5/11/15 for a broken hydraulic pump. |
1431427239 | 2015-05-11 | Salt Water Injection Well | No Violations | Workover in progress. Test casing to 700 psig and it fell back to 665 in 15 minutes. Drilling cement. |
1431600483 | 2015-05-13 | Salt Water Injection Well | No Violations | Workover in progress. The pressure test of 5/12/15 failed, falling 45 psig in 15 minutes. They drilled to joints and retested and that test also failed, falling 100 psig in 15 minutes. The decision was made to drill out the cement and packer and run and cement 2-7/8 Regular tubing. |
1433327916 | 2015-06-02 | Casing String Witnessed | No Violations | The rig ran 96 joints of 2-7/8 Regular tubing and the packer assembly inside the 4-1/2 casing to 3012. The packer was set and 12,00 of tension pulled on the packer. Petroset Services cemented the tubing in the well with 140 sacks of Class A cement. See the casing ticket for the details. The well circulated and the gel ahead of the cement made it back to the surface but there was no cement returned to the surface. Circulation dwindled to a trickle for a barrel or two during the job and then came back. After displacement waws reached, the tubing was shut in and the casing dropped immediately. |
1433846711 | 2015-06-04 | Salt Water Injection Well | No Violations | Workover in progress. The fluid in the 2-7/8 tubing was at 2 feet. The rig ran the small swab tools and found the top of the cement at 2800. This was considerably higher than anticipated ( displacement was to be to 2990). The new 1-1/2 tubing was delivered this date. The rig ran the tubing to the top of the cement near 2800 and commenced drilling out the cement. |
1434945285 | 2015-11-09 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during our inspection. |
1466442682 | 2010-04-01 | Salt Water Injection Well | No Violations | The well area has been graded but still needs seeded. Well pressure is negative pressure with vacuum.The annulus is just 0 with no vacuum. |
1470760495 | 2008-12-19 | Salt Water Injection Well | No Violations | Arrive today for test and had to wait on dozer because everybody is stuck.Then wait on Pumptruck. Pumped 40 bbl freshwater with 4 gallons of Halliburton anhib and set packer above the perfs used to circulate cement to surface on the 4 inch.1st test failed , 2nd test failed, 3 rd test failed.Then found out that pumptruck could not pump more that 300 psi without leaking back to his tank.Next wait on another pumptruck .After pumptruck arrived we tested at 2885 ft and test failed ,pulled up 3 jts test failed ,pulled up 5 joints test failed.Pulled up to 1600 ft before test would hold 700 psi. |
1472668588 | 2017-01-18 | Salt Water Injection Well | No Violations | Inspection today revealed that one company owned vacuum truck was transferring oil from storage tanks during my inspection. |
1474391648 | 2007-06-04 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1615629740 Barrel counter needs repaired or replaced as part of the permit conditions .Also the dike needs repaired after being cut to replace pipe .There is an area behind the dike which has low vegetation due to brine .Excavate the s |
1479175175 | 2016-06-06 | Salt Water Injection Well | No Violations | Still no positive pressure on the annulus. The area around the well head has dried out and needs seeded and mulched. The pit from the last workover has setled out and needs leveled and seeded and mulched. Left word with a company representative to have it done. There are several buckets of leaves and other debris that has been screened out of the brine that need removed. Left word to that effect with a company representative. There were no other problems noted at the time of the inspection. |
1480613356 | 2008-12-15 | Salt Water Injection Well | No Violations | Ran in with 2 3/8 tubing and rebuilt R-4 TO 2947 ft. Last set at 2948 ft. only gave up 1 ft.Omega pumped 41 bbls of freshwater mixed with 4 gallons of anhib.Set packer with 12,000 lbs tension and tested 4 times and all tests failed.Advise pull packer out and run in with scraper and clean up area where packer is to be set. |
1488297791 | 2017-02-28 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2016. Please submit the appropriate reports by March 14, 2017. Also S & H Water Service has an outstanding compliance notice for fees reports for the 2nd, 3rd, and 4th quarter of 2015 that need to be reported. |
1492173423 | 2015-05-14 | Salt Water Injection Well | No Violations | Workover in progress. All the squeeze cement has been drill and they are drilling on the bridge plug. It will be pushed to botom as soon as it is drilled loose. 2-7/8 tubing will be run and cemented in the well. |
1506627941 | 2010-03-04 | Salt Water Injection Well | No Violations | restoration of wellsite needs done in the spring. |
1508432749 | 2007-10-01 | Salt Water Injection Well | No Violations | Arrive today to collect photos and see how the vault and liner have been installed. |
1516382867 | 2007-09-04 | Salt Water Injection Well | No Violations | Clean up of oil spill has begun today.The tanks are to be pulled and the area under tanks is to be excavated and removed.Next dike is to be rebuilt and a liner installed.Today the tanks are being pulled. |
1533378463 | 2006-09-06 | Salt Water Injection Well | No Violations | Arrive today and found that the flow meter has not been repaired and that no clean up has been done? |
1535983586 | 2011-12-06 | Salt Water Injection Well | No Violations | Well was not in operation at time of inspection. Sump was full, but contained. Annulus 185 PSIG. The tubing was on vacuum. No problems noted. |
1536754144 | 2015-04-27 | Salt Water Injection Well | No Violations | Workover in progress. They have drilled out cement to 2031. A pressure test at that depth to 740 psig fell back to 710 in 15 minutes which is wit in test perameters. They are continuing to drill out cement. |
1551509072 | 2007-09-11 | Salt Water Injection Well | No Violations | Found that the tanks have been removed and that the soil below the tanks has been removed .The area has been backfilled after the soil was removed. |
1557418932 | 2007-09-24 | Salt Water Injection Well | No Violations | Met with clean up crew and they are placing liner in the dike area and advise on prep work needed before liner is damaged. |
1563647238 | 2015-01-15 | Salt Water Injection Well | No Violations | Well inspection on this day indicated that well has equalized and Todd Miller called company rep and requested that they shut well down to determine if packer has integrity problem or if tubing lost integrity, company rep stated that they would get service rig on schedule to work on well.
Note: Called UIC supervisor and requested suspension order to cease operations until well could be fixed. |
1586095120 | 2020-3-30 0:00: | SW | No Violations | |
1588259447 | 2013-03-14 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it was noted that a company owned vacuum truck was unloading at facility during my inspection. |
1598809582 | 2015-06-11 | Salt Water Injection Well | No Violations | Workover in progress. The formation was acidized with 1000 gallons of acid thru the 2-7/8 tubing. This treatment wasdone to clean up the formation after a lengthy workover. The well went on vacuum. |
1602638266 | 2015-03-11 | Salt Water Injection Well | No Violations | Both the tubing and the annulus are on vacuum. Contacted Gary Staggs for a pressure test on the annulus. |
1608046478 | 2007-09-24 | Salt Water Injection Well | No Violations | Arrive to set liners and tanks.Three tanks are reset and also cement vault.The vault has the liner under it so it is not a buried tank.Well is not in operation. |
1615629740 | 2007-06-04 | Salt Water Injection Well | Violations Noted | Barrel counter needs repaired or replaced as part of the permit conditions .Also the dike needs repaired after being cut to replace pipe .There is an area behind the dike which has low vegetation due to brine .Excavate the soil and replace with clean soil . Then establish vegetation with seed and mulch . |
1617429636 | 2004-01-21 | Salt Water Injection Well | No Violations | Injection pressure 0-- annulus pressure 60----flow meter reset to 0 |
1623752386 | 2015-07-16 | Salt Water Injection Well | No Violations | Inspection revealed that well is still on vacuum after owner recently reworked well again.
Dike capacity is as follows 69x28x36 high dike walls=1030 bbl. |
1626208298 | 2017-12-03 | Salt Water Injection Well | No Violations | Well not in operation at this time. |
1637110246 | 2009-01-29 | Salt Water Injection Well | No Violations | Arrive today to find that Omega has done a 3rd cement job but did not call me .They set cement thru tubing set at 2222 ft back to 1500 ft. .Bishop Well did tag top of cement at 1500 ft and drilled out to 2240 ft.Today they have tubing in the hole to 2294 ft .The plan is to pack off tubing and test thru tubing and pressure the whole string .3 Tests failed to go above 500 psi .Next ran in to 2700 ft and Omega will cement back to 1700 ft and sqeeze this whole section.Reverse circulate at 1200 ft .Pack off tubing at that depth and pressure up to 1500 psi. and shut in for two days.Omega used 60 sks .and 2 % gel with cement weight of 14.6 |
1654299354 | 2017-11-07 | Salt Water Injection Well | No Violations | Inspection revealed that well appears not to be in operation at this time it was noted that clean water tank going to injection pump has been disconnected at this time. |
1663435962 | 2014-03-25 | Salt Water Injection Well | No Violations | There was 158 psig on the annulus and the tubing was on vacuum. There were no problems noted at the time of the inspection. |
1669647877 | 2017-12-12 | Salt Water Injection Well | Violations Noted | Inspection revealed that well has equalized and apparently has hole in tubing and Bishop Well Service was on site with service rig attempting to get well to pass required test they released packer and was able to go down hole with packer but unable to pull it up they are going to devise plan for owner in the near future.
Note: Well owner will need to submit repair plan to fix well within 30 days to the UIC section failure to do so may result in further action. |
1677276917 | 2009-07-29 | Salt Water Injection Well | No Violations | Site needs to be restored. Area has been graded but needs more of that and seeded. |
1692468700 | 2008-03-25 | Salt Water Injection Well | No Violations | Check tanks and dike which has just been installed and it is making the winter just as planned.No problems with any of the system so far. |
1696772540 | 2008-05-27 | Salt Water Injection Well | No Violations | |
1698462566 | 2005-08-15 | Salt Water Injection Well | No Violations | |
1740865456 | 2015-06-11 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform acid treatment on said well, they plan on running packer and tubing in well tomorrow and possibly be ready to pressure test on Monday. |
1742107538 | 2016-12-02 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and it was noted that there was replumbing of the offload line done since my last inspection. |
1748742869 | 2004-12-27 | Salt Water Injection Well | No Violations | Electric is out in area and well is not in operation at this time.Flow meter is not working and I advised pumper that it should be fixed A.S.A.P. |
1762892978 | 2015-06-11 | Salt Water Injection Well | No Violations | Workover in progress. Producers Services is on location to do an acid clean -up and mini stimulation of the well. The well was on vacuum. Producers acidized with 1000 gallons of acid and over displaced the the acid into the formation with 2 tubing volumes (35 bbls). See the stimulation report for the details. |
176591686 | 2013-9-23 0:00: | SW | No Violations | |
177631121 | 2013-8-27 0:00: | SW | No Violations | |
1783179706 | 2014-10-07 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2008, 2009, 2010, 2011, 2012, and 2013. |
179960665 | 2015-5-5 0:00:0 | SW | No Violations | |
1816026033 | 2008-10-02 | Salt Water Injection Well | No Violations | Found well in neutral today.No injection because it was not on vaccum.Could not get valve to turn on annulus to see if that was on vaccum also.No work done on unloading pad .Does not appear that it has had more brine drain off ,but the area affected has not been cleaned up either.Looks like nothing done. |
18176036 | 2002-3-26 0:00: | SW | No Violations | 1.20 |
183454666 | 2010-4-28 0:00: | SW | No Violations | 2.00 |
1862225447 | 2017-07-13 | Salt Water Injection Well | No Violations | The facility is okay. The gate was closed. The ID is visible and in good repair. The annulus had 22 psig and tubing had 0 psig. |
1865496334 | 2012-11-23 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not operating today and it was noted that unloading pad is in need of a good cleaning. |
1868579322 | 2014-05-19 | Salt Water Injection Well | No Violations | This is a salt water didposal well. There were no problems noted at either the tank site of the well at the time of the inspection. |
1877419326 | 2009-01-05 | Salt Water Injection Well | No Violations | There has been a wire line plug set at 2708 ft. Arrive today to test casing from that depth back to surface. Test was scheduled for 8: 15 and had to wait on equipment , dozer , pumptruck ,water truck.Next had to wait on wellhead equipment because we could not hook up to test as set up.Test # 1 ,2,3 failed.Was able to pressure up to 500 psi but had to have rate of 2 1/2 barrels per minute .Then ran out of water , w/o more water and ran in hole with tubing and spot 30 sk plug and pressure up and moved 5 bbl on squeeze. |
1908168121 | 2004-10-19 | Salt Water Injection Well | No Violations | The flow meter is still off line and needs repaired.Talk with Gary and he advised that Halliburton is to fix unit soon. |
1922188520 | 2018-05-03 | Salt Water Injection Well | No Violations | Inspection today revealed that well is currently not being used ,owner stated that he is planning on changing out clean water tank next week and then resuming injection operations at that point. |
1930338520 | 2003-11-07 | Salt Water Injection Well | No Violations | The area where line leak occurred has been cleaned up and has good vegetation. The site has been graded and seeded and meets requirements.Flow meter has been reset to 0 or is not working. |
1966369284 | 2013-04-18 | Salt Water Injection Well | No Violations | The tubing was on vacuum and the annulus had 76 psig. There were no problems noted at the time of the inspection. |
1972240462 | 2012-04-03 | Salt Water Injection Well | No Violations | No problems noted at tanks or well. There is pressure on the annulus and the well is on vacuum. |
2019182150 | 2005-10-13 | Salt Water Injection Well | No Violations | |
2019976507 | 2009-04-13 | Salt Water Injection Well | No Violations | Checked pressure on annulus and found possitive pressure but not enough to read with gauge.Site needs restoration again. Mostly grade and seed . |
2028946349 | 2015-06-15 | Salt Water Injection Well | No Violations | On location for an MIT on the new tubing string and packer in this well, The tubing was run to 2976.5 on 6/11/15 (witnessed by this inspector). The well was on vacuum this morning. Displaced 9 bbls of inhibited fresh water down the annulus and set the packer in tension. The well would not test. Replaced a valve on the annulus and the well still would not test. The operator then released the packer and removed the head and affixed a head on the 4-1/2 casing to center and keep stretch on the 2-7/8. A NEW valve was put on the 2-7/8 head. Inhibited fresh water was again displaced down the annulus and the packer set in tension. The annulus was pressured up to 800 psig. The annulus dropped 5 psig in 15 minutes. The MIT passed. The annulus pressure was bled down to 250 psig. And shut in. |
2031602563 | 2004-08-31 | Salt Water Injection Well | No Violations | Found that the flow meter had been broken and needs repaired or replaced.Advised operator and repairs are to be made. |
2072585562 | 2008-07-21 | Salt Water Injection Well | Violations Noted | Found 2 300 bbl tanks on site - one full and the other empty.One tank has a small kill area in front of the tank.Contact Gary and advise pump tanks off and remove from site. |
2079765021 | 2013-11-21 | Salt Water Injection Well | No Violations | The annulus pressure is 57 psig and the tubing is on vacuum. There were no problems noted at the well or the facility. |
2082249612 | 2007-09-04 | Salt Water Injection Well | No Violations | Clean up began today and clean up crew is excavating soil inside and outside of the dike.Next They will pull tank and remove most of the dike and excavate under dike and tank area.The area is then to have the dike rebuilt on a larger scale and more tanks |
2090533878 | 2011-09-19 | Salt Water Injection Well | Violations Noted | No problems noted at facility. Unable to check pressures on tubing and annulus as there are no 1/4 valves on either. Notified owner again to install valves. |
2095640345 | 2019-6-26 0:00: | SW | No Violations | |
2143351023 | 2015-04-28 | Salt Water Injection Well | No Violations | Workover. They pressure tested the well at 2200. The casing was pressured up to 740 psig for 15 minutes and dropped off to 708 psig which is with in the 5 % parameters. They are continuing to drill cement. |
242168301 | 2015-1-15 0:00: | SW | No Violations | |
243432746 | 2012-7-5 0:00:0 | SW | No Violations | |
26676084 | 2002-5-15 0:00: | SW | No Violations | 1.70 |
291547947 | 2007-10-4 0:00: | SW | No Violations | 2.70 |
306734524 | 2008-9-9 0:00:0 | SW | No Violations | 2.00 |
34775933 | 2002-8-1 0:00:0 | SW | No Violations | 1.70 |
38076161 | 2002-8-19 0:00: | SW | No Violations | 1.20 |
390968380 | 2015-4-23 0:00: | SW | No Violations | |
42676192 | 2002-9-12 0:00: | SW | No Violations | 1.00 |
42876194 | 2002-9-12 0:00: | SW | No Violations | 1.00 |
43176197 | 2002-9-11 0:00: | SW | No Violations | 1.20 |
43676201 | 2002-9-16 0:00: | SW | No Violations | 1.20 |
43776202 | 2002-9-17 0:00: | SW | No Violations | 4.00 |
45476216 | 2002-10-15 0:00 | SW | No Violations | 1.20 |
457280984 | 2007-9-5 0:00:0 | SW | No Violations | 1.50 |
458717631 | 2015-4-24 0:00: | SW | No Violations | |
466490831 | 2010-6-7 0:00:0 | PL | No Violations | 2.00 |
473311371 | 2016-5-9 0:00:0 | SW | No Violations | |
492469382 | 2016-1-28 0:00: | SW | No Violations | |
575178217 | 2017-5-3 0:00:0 | SW | No Violations | |
593568587 | 2009-5-26 0:00: | SW | No Violations | 1.70 |
618736531 | 2007-11-14 0:00 | SW | No Violations | 1.50 |
618764357 | 2005-10-20 0:00 | SW | No Violations | |
625688573 | 2005-10-20 0:00 | SW | No Violations | |
634946996 | 2011-3-8 0:00:0 | SW | No Violations | 2.00 |
657964960 | 2011-1-5 0:00:0 | SW | No Violations | 2.00 |
727477714 | 2018-2-1 0:00:0 | SW | No Violations | |
816083746 | 2018-2-16 0:00: | SW | No Violations | |
819410159 | 2018-5-3 0:00:0 | SW | No Violations | |
825361710 | 2007-9-27 0:00: | SW | No Violations | 2.70 |
830457375 | 2015-1-22 0:00: | SW | No Violations | |
845213527 | 2002-12-19 0:00 | SM | No Violations | 1.20 |
849760304 | 2015-1-28 0:00: | SW | No Violations | |
866172159 | 2018-7-18 0:00: | SW | No Violations | |
898303326 | 2017-8-1 0:00:0 | SW | No Violations | |
906071943 | 2007-9-13 0:00: | SW | No Violations | 4.70 |
949342589 | 2015-5-4 0:00:0 | SW | No Violations | |
95793063 | 2015-4-29 0:00: | SW | No Violations | |
985608243 | 2018-8-29 0:00: | SW | No Violations | |
PL15344 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0111893205 | US-OH-103019 | 2017-08-18 | 9-3-04B | Failure to file salt water injection annual report |
0140202067 | US-OH-111900 | 2010-06-24 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
0228844945 | US-OH-122283 | 2018-03-21 | 9-3-05[C] | Failure to pass required test |
0242168301 | US-OH-122435 | 2015-01-20 | Mechanical failure/contamination | |
0306734524 | US-OH-123192 | 2009-01-21 | Pollution/Contamination | |
0335353057 | US-OH-123515 | 2011-09-23 | Pollution/Contamination | |
0335353057 | US-OH-123516 | 2011-09-23 | Failure to monitor annulus pressure | |
0568393947 | US-OH-126392 | 2006-08-21 | Pollution/Contamination | |
0618764357 | US-OH-126989 | 2005-10-20 | Failure to monitor pressures/volumes | |
0625688573 | US-OH-127078 | 2005-10-20 | Failure to monitor pressures/volumes | |
0708759415 | US-OH-127995 | 2007-06-07 | Failure to monitor pressures/volumes | |
0727477714 | US-OH-128290 | 2018-02-28 | 9-3-07(H) | Mechanical failure/contamination |
0816083746 | US-OH-129290 | 2018-12-31 | NONE | Failure to report disposal fees |
0819410159 | US-OH-129335 | 2018-12-31 | 9-3-04B | Failure to file salt water injection annual report |
0828768665 | US-OH-129446 | 2005-03-02 | Pollution/Contamination | |
0841319213 | US-OH-129575 | 2019-05-09 | Failure to file salt water injection annual report | |
0895627183 | US-OH-130142 | 2007-01-30 | Failure to monitor pressures/volumes | |
0946245506 | US-OH-130821 | 2017-03-06 | 9-3-04B | Failure to file salt water injection annual report |
1006785019 | US-OH-100509 | 2019-04-08 | Failure to report disposal fees | |
1028238988 | US-OH-100545 | 2007-09-21 | Pollution/Contamination | |
1028238988 | US-OH-100546 | 2007-09-21 | Failure to monitor pressures/volumes | |
1028238988 | US-OH-100547 | 2007-09-21 | Pits not liquid tight/Improper construction or use | |
1615629740 | US-OH-115866 | 2007-07-11 | Pollution/Contamination | |
1615629740 | US-OH-115867 | 2007-07-11 | Failure to monitor pressures/volumes | |
1669647877 | US-OH-116506 | 2018-01-13 | 9-3-05[C] | Failure to pass required test |
1669647877 | US-OH-116507 | 2018-01-13 | 9-3-07(H) | Mechanical failure/contamination |
1783179706 | US-OH-117760 | 2016-01-06 | Failure to file salt water injection annual report | |
2072585562 | US-OH-121141 | 2008-10-08 | Failure to meet safety/distance requriements | |
2090533878 | US-OH-121352 | 2011-09-19 | Violation of injection tubing/fitting requirements |
For data sources see[5]