Well ID: 34-075-24558 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.65,"lon":-81.88,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Holmes | |
Municipality: Prairie Township | |
Operator Name: PONDEROSA CONSULTING SERVICES | |
Well Pad ID: | |
Farm/Lease Name: SHAW DORIS A UNIT | |
License Status: Producing | |
License Date: 1985-06-19 | |
Spud Date: 1985-08-16 | |
Spud Drilling Contractor: H A D INC | |
Final Drill Date: 1985-08-23 | |
Well Total Depth: 3610.00 ft | |
Configuration: Vertical | |
Latitude: 40.650000 | |
Longitude: -81.880000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1985-06-19 | Issued Date 6/19/85 Expired Date 6/19/86 Acres 0020070 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03610 Proposed Drill Depth 03610 |
Original Spud | 1985-08-16 | |
Completed | 1985-08-23 | |
Reached Total Depth | 1985-08-23 | |
CO | 1985-09-24 | 2180 PONDEROSA CONSULT SER INC GeoDate 6/19/85 |
Completion Report Received | 1985-09-30 | |
Construction Permit Expires | 1986-06-19 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3437 | 3522 | 0 |
3437 | 3522 | 0 | |
2006-09-11 | 3459 | 3516 | 18 |
3459 | 3516 | 18 | |
3437 | 3522 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 72000 Gal | 25000 | FRAC;H2O,SAND,N2 | ||
N2 | 0 | 180 Mscf | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1092314635 | 2019-6-3 0:00:0 | PW | No Violations | 0.80 |
-1541919021 | 2017-6-8 0:00:0 | PW | No Violations | |
-451266116 | 2020-9-29 0:00: | PW | No Violations | 1.00 |
-781530269 | 2014-12-12 0:00 | PW | No Violations | |
-964103558 | 2020-10-14 0:00 | PW | No Violations | 0.50 |
000PL15227 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0747328469 | 2019-01-24 | Production Wells | No Violations
-394 issued on 12/06/2018 I found an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, a 1 1/2-inch diameter tubing, operated by a plunger lift system. The production equipment is made up of one 100 bbl. steel tank, a 25-bbl. plastic tank, a vertical separator, a recording gauge. The tank is not properly identified. The production reporting is up to date, but the last commercial production was in the year of 2008. The landowner has stated they want the well plugged and abandon. | |
0781530269 | 2014-12-12 | Production Wells | Violations Noted | This well is not producing. There is no ID. There have been no producion reports submitted for 2013. This well shall be plugged and abandoned. Production preports shall be submitted to Columbus for 2013 and a valid legible ID shall be placed on the |
1092314635 | 2019-06-03 | Production Wells | No Violations
-394 issued on 12/06/2018 I found an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, a 1 1/2-inch diameter tubing, operated by a plunger lift system. The production equipment is made up of one 100 bbl. steel tank, a 25-bbl. plastic tank, a vertical separator, a recording gauge. The tank is not properly identified. The production reporting is not up to date. The last commercial production was in the year of 2008. The landowner has stated they want the well plugged and abandon. The production for the year of 2018 has not been reported. | |
1533735454 | 2018-08-08 | Production Wells | No Violations | This is a follow up inspection to compliance notice 781530269 issued on 12/15/2014 I found an 8 5/8-inch diameter casing, 4 1/2-inch diameter casing, a 1 1/2-inch diameter tubing, operated by a plunger lift system. The production equipment is made up of one 100 bbl. steel tank, a vertical separator, a recording gauge. The tank is not properly identified. The production reporting is up to date, but the last commercial production was in the year of 2008. The landowner has stated they want the well plugged and abandon. |
1541919021 | 2017-06-08 | Production Wells | No Violations | This plunger lift well is still not producing commercially. Some house gas is being used (off the well head) but the domestic consumer was not home at the time of the inspection to tell me how reliable it is. There still are no IDs on either the well or the tank. The production records have been brought up to date thru 2015 |
1602680428 | 2020-9-29 0:00: | PW | No Violations | 0.50 |
1619549175 | 2016-10-24 | Production Wells | Violations Noted | This plunger lift well is producing only some house gas to one dwelling. There has been no commercial production for years. There is no ID on the tank or well. There were no other problems noted at the time of the inspection. The Operator shall install an ID with the Operator Name, Well Name, Permit Number, County, and an Emergencey Telephone Number as soon as practicable. |
1662215197 | 2018-06-04 | Production Wells | No Violations | This is a follow up inspection to compliance notice 7811530269 issued on 12/15/2014 I found an 8 5/8 inch diameter casing, 4 1/2 inch diameter casing, a 1 1/2 inch diameter tubing, operated by a plunger lift system. The production equipment is made up of two 100 bbl. steel tanks, two vertical separators, and two 25 bbl. plastic tanks. The tanks are not properly identified. The heater tubes on both tanks are leaking. The production equipment is shared with another well. In talking with the property owner, they do not receive any domestic gas. |
747328469 | 2019-1-24 0:00: | PW | No Violations | 0.80 |
PL15227 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0781530269 | US-OH-128884 | 2015-01-08 | Failure to legibly identify well | |
0781530269 | US-OH-128885 | 2015-01-08 | Well shall be plugged | |
0781530269 | US-OH-128886 | 2015-01-08 | Statement of annual production not filed | |
1619549175 | US-OH-115915 | 2016-11-14 | Failure to legibly identify well |