34-075-25252

Well Details

Well ID: 34-075-25252
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Hardy Township
Operator Name: MASON DRILLING INC
Well Pad ID:
Farm/Lease Name: HUMMEL
License Status: Producing
License Date: 1997-02-05
Spud Date: 1997-02-24
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1997-02-28
Well Total Depth: 3588.00 ft
Configuration: Vertical
Latitude: 40.550000
Longitude: -81.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1997-02-05 2834 BI JOE DEVELOPMENT INC GeoDate 2/5/97
Oil and Gas 1997-02-05 Issued Date 2/5/97 Expired Date 2/5/98 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1997-02-24
Completed 1997-02-28
Reached Total Depth 1997-02-28
Completion Report Received 1997-04-23
Construction Permit Expires 1998-02-05
Change of Owner 2004-03-12 Operator changed from 2834, BI JOE DEVELOPMENT INC to 1983, MASON DRILLING INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-07-02 3418 3495 23
3418 3495 23
3418 3495 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 79900 Gal 40000 BKDN 2410 PSI
H2O 0 79900 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 BI JOE DEVELOPMENT INC 384.00 207.00 255
1998 BI JOE DEVELOPMENT INC 1708.00 51.00 365
1999 BI JOE DEVELOPMENT INC 1413.00 13.00 365
2000 BI JOE DEVELOPMENT INC 1085.00 0.00 365
2001 BI JOE DEVELOPMENT INC 1987.00 492.00 365
2002 BI JOE DEVELOPMENT INC 2201.00 0.00 365
2003 BI JOE DEVELOPMENT INC 545.00 0.00 273
2004 MASON DRILLING INC 2652.00 472.00 365
2005 MASON DRILLING INC 2483.00 382.00 365
2006 MASON DRILLING INC 2046.00 347.00 365
2007 MASON DRILLING INC 1988.00 282.00 365
2008 MASON DRILLING INC 1723.00 298.00 365
2009 MASON DRILLING INC 1529.00 254.00 365
2010 MASON DRILLING INC 1454.00 270.00 365
2011 MASON DRILLING INC 1305.00 232.00 365
2012 MASON DRILLING INC 1234.00 255.00 366
2013 MASON DRILLING INC 1032.00 185.00 365
2014 MASON DRILLING INC 1124.00 199.00 365
2015 MASON DRILLING INC 1069.00 254.00 365
2016 MASON DRILLING INC 856.00 182.00 365
2017 MASON DRILLING INC 1078.00 191.00 365
2018 MASON DRILLING INC 1191.00 235.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 BI JOE DEVELOPMENT INC Brine 538 255
1998 BI JOE DEVELOPMENT INC Brine 62 365
1999 BI JOE DEVELOPMENT INC Brine 15 365
2000 BI JOE DEVELOPMENT INC Brine 30 365
2001 BI JOE DEVELOPMENT INC Brine 10 365
2002 BI JOE DEVELOPMENT INC Brine 30 365
2003 MASON DRILLING INC Brine 0
2004 MASON DRILLING INC Brine 21 365
2005 MASON DRILLING INC Brine 20 365
2006 MASON DRILLING INC Brine 15 365
2007 MASON DRILLING INC Brine 0 365
2008 MASON DRILLING INC Brine 20 365
2009 MASON DRILLING INC Brine 49 365
2010 MASON DRILLING INC Brine 51 365
2011 MASON DRILLING INC Brine 0 365
2012 MASON DRILLING INC Brine 0 366
2013 MASON DRILLING INC Brine 1 365
2014 MASON DRILLING INC Brine 0 365
2015 MASON DRILLING INC Brine 0 365
2016 MASON DRILLING INC Brine 0 365
2017 MASON DRILLING INC Brine 0 365
2018 MASON DRILLING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1118244222 2014-3-7 0:00:0 PW No Violations
-28400320 2018-7-11 0:00: PW No Violations 0.50
0028400320 2018-07-11 Production Wells No Violations On the day of my inspection I found, an 8 5/8 inch diameter casing, 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing, operated by a pumping unit with an electric motor. The production equipment is made up of one 100 bbl. steel tank. The tank is properly identified and production reporting is up to date.
1118244222 2014-03-07 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1916864745 2016-05-17 Production Wells No Violations This is a producing pump jack well. The high production tank was leaking out the bottom. The water truck driver switched tanks and emptied the leaking tank. The tank will be removed by the operator. There were no other problems noted at the time of the inspection.

For data sources see[9]