34-089-22097

Well Details

Well ID: 34-089-22097
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Pike Township
Operator Name: ROYALTY ENTERPRISES INC
Well Pad ID:
Farm/Lease Name: STICHERT KARL & JAQUELINE
License Status: Final Restoration
License Date: 2010-12-29
Spud Date: 2006-03-23
Spud Drilling Contractor:
Final Drill Date: 1964-05-18
Well Total Depth: 2999.00 ft
Configuration: Vertical
Latitude: 40.210000
Longitude: -82.180000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1964-04-11
Completed 1964-05-18
Reached Total Depth 1964-05-18
CO 1986-07-28 20 WITCO CORP GeoDate 7/28/86
COMBINATION WELL 1986-07-28 Issued Date 7/28/86 Expired Date 7/28/87 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date 8/28/86
APP 2006-03-08 Proposed Formations:CLINTON, Issued Date:3/8/2006, Expired Date:3/8/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Change of Owner 2008-06-20 Operator changed from 565, MORAN RONALD F to 4484, ROYALTY ENTERPRISES INC
APP 2008-07-25 Proposed Formations:NEWBURG, Issued Date:7/25/2008, Expired Date:7/25/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OTH, Proposed Well Class:O
APP 2010-12-29 Proposed Formations:CLINTON, Issued Date:12/29/2010, Expired Date:12/28/2012 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2011-08-04
Construction Permit Expires 2012-12-28
Record Last Modified 2014-07-10

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 0 100MCF

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 WITCO CORP 0.00 113.00 365
1985 WITCO CORP 0.00 114.00 365
1986 WITCO CORP 0.00 46.00 229

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 WITCO CORP Brine 0 365
1985 WITCO CORP Brine 0 365
1986 WITCO CORP Brine 0 229

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1199513331 2008-8-18 0:00: PW No Violations
-1222492868 2012-9-6 0:00:0 FR No Violations
-1304368964 2012-4-6 0:00:0 AM No Violations
-1389321709 2012-10-3 0:00: FR No Violations
-1472580906 2011-6-2 0:00:0 PW No Violations
-1649630620 2010-8-17 0:00: PW No Violations
-1803529966 2007-11-21 0:00 PW No Violations
-189966611 2007-12-12 0:00 PW No Violations
-2040729398 2012-8-23 0:00: FR No Violations
-249694554 2012-6-25 0:00: FR No Violations
-433132063 2010-7-30 0:00: PW No Violations
-458335606 2011-7-13 0:00: PW No Violations 1.00
-533310995 2014-4-21 0:00: FR No Violations
-69655190 2011-8-2 0:00:0 PB No Violations
0000016176 Final Restoration No Violations PASSED Y WITNESSED 2/28/94 INSPECTOR LEWIS BELL DATE 02/2819/94 DATA FROM OLD VAX INFO
0031168779 2012-04-03 Final Restoration Violations Noted The Division received a landowner request to check status of Final Restoration. An inspection revealed that the Final Restoration does not meet ORC 1509.072. During the inspection, it was noted that oilfield debris still exists such as, tanks and production lines. The lease road and well location have not been restored. The well owner shall: Remove all oilfield debris from location; Grade and establish vegetative cover along lease road to tank battery and turn around location(s); and Grade and establish vegetative cover at well location and earthen dike/ tank battery location. The well owner was given a verbal notice prior to the issuance of this Compliance Notice. Failure to comply may result in further enforcement action.
0069655190 2011-08-02 Plug / Plug Back No Violations I witnessed plugging operations today.
0189966611 2007-12-12 Production Wells No Violations Stopped by well location today. The well is capable. There is nobody on location and no evidence of brine being hauled. Brine tank on top of hill is full.
0249694554 2012-06-25 Final Restoration No Violations A follow-up inspection revealed non-compliance with ORC 1509.072. The well owner has done work since the initial inspection. The horizontal tank near SR 79 and 100 bbl tanks at tank battery location have been removed. Section of steel plastic still exist and will need to be removed. The tank battery location will require the removal of gravel; dike graded and vegetation established. The well location, lease road and turn around locations have not been restored and will require vegetative cover. Note: Lease road leading to tank battery will no longer be utilized by owner of existing well on property.
0413706023 2011-08-04 Plug / Plug Back No Violations An inspection of plugging status revealed plugging contractor washing clay to the surface.
0433132063 2010-07-30 Production Wells No Violations There is a pumping unit on the well and the well is capable of production. The well was not pumping. There approximately 42 inches of fluid in the 200 barrel vertical tank on the top of the hill. There is approximately 30 inches of fluid in the horizontal tank at the bottom of the hill.
0458335606 2011-07-13 Production Wells No Violations An inspection revealed that well and saltwater tank status remains unchanged since the last inspection. The pumping unit remains at location but has been disconnected and fluid level within 200 bbl horizontal saltwater tank remains 2/3 full. Note: Plug Permit issued for this well.
0533310995 2014-04-21 Final Restoration No Violations Inspect location. Well has been plugged. Equipment and debris has been removed. Vegetation established. Inspection meets ORC 1509.072 requirements.
0590187312 2012-10-05 Final Restoration No Violations I inspected this location today. The area around the well and the turn around on St. Rt. 79 have been graded. The culvert has been removed. Gravel has been piled up and is ready to be hauled away. The graded areas are ready for seed and straw.
0662952380 2008-07-15 Production Wells No Violations The inspection revealed that the tanker truck that has been here is off location.
0727213507 2008-03-31 Production Wells No Violations I inspected well location with Jeff Fry. No violation noted this date.
0974308115 2008-06-19 Production Wells No Violations I inspected the well location at the request of Jeff Fry. I took brine samples from the line coming from the tank.
1089057093 2012-04-03 Final Restoration No Violations FOLLOW UP TO NOV # 31168779 The Division received a landowner request to check status of Final Restoration. An inspection revealed that the Final Restoration does not meet ORC 1509.072. During the inspection, it was noted that oilfield debris still exists such as, tanks and production lines. The lease road and well location have not been restored. The well owner shall: Remove all oilfield debris from location; Grade and establish vegetative cover along lease road to tank battery and turn around location(s); and Grade and establish vegetative cover at well location and earthen dike/ tank battery location. The well owner was given a verbal notice prior to the issuance of this Compliance Notice. Failure to comply may result in further enforcement action.
1196436648 2012-08-23 Final Restoration No Violations I inspected this location today accompanied by Brent Bear. This inspection revealed non-compliance.
1199513331 2008-08-18 Production Wells No Violations The inspection revealed that there has been a new horizontal tank set on location. The pumping unit is active. There is new identification posted at the well head. No violations noted this date.
1222492868 2012-09-06 Final Restoration No Violations Today I met with landowner Mr. Karl Stichert. He informed me that the final restoration is pass due and showed me everything that Mr. Clayton King is responsible for reclaiming. Mr. King has already began working on removing the culvert along Rt. 79.
1227625807 2008-11-25 Production Wells No Violations I inspected the well location today with Jeff Fry. Clayton King was on location. Two new tanks have been set. Jeff talked with him about some of his outstanding NOVs. He is still producing brine from the Clinton formation.
1285337627 2010-09-23 Production Wells No Violations Well has pump jack and is pumping. Horizontal brine tank is apprx. 2/3 full.
1304368964 2012-04-06 Administrative Inspection No Violations At 9:07AM, I called and left a voicemail message for the well owner, Mr. Clayton King, regarding delinquent Final Restoration. Request a return call.
1343856900 2011-08-01 Plug / Plug Back No Violations An inspection revealed service rig on location pulling tubing.
1389321709 2012-10-03 Final Restoration No Violations I inspected this location. No one working during inspection. I placed a phone call to Clayton King. He informed me that dozer work will beging tomorrow.
1449369861 2012-11-26 Final Restoration No Violations Inspected this location today. Gravel pile near entrance has been removed. Debris has not been removed from location. Gravel in dike needs to be removed and area needs graded. Restoration not complete.
1472580906 2011-06-02 Production Wells No Violations An inspection of this well revealed rods and tubing remain in the wellbore, but pumping unit has been disconnected. The valves were observed to be open on both casing and pumping tee side of well. The casing side of well contained 1 yellow plastic, which transitions into 3/4 black plastic then 1/2 black plastic. While facing the well, the line was routed to the right in the field to burn pile location. The 200 bbl horizontal saltwater tank near well location was approx 2/3 full. A valve on bottom of 200bbl vertical tank (on top of hill at tank battery) was open. The fluid level was approx 1. No activity or personnel at location.
16176 FR No Violations
1649630620 2010-08-17 Production Wells No Violations I inspected the well location with Jeff Fry. There is a pumping unit on the well and the well is capable of production. The well was not pumping. There approximately 42 inches of fluid in the 200 barrel vertical tank on the top of the hill. There is approximately 30 inches of fluid in the horizontal tank at the bottom of the hill.
1803529966 2007-11-21 Production Wells No Violations I inspected the well location with Jeff Fry. There is no identification posted at the well head or the tank battery. There is a pumping unit on the well and the well is capable of production. There is a plastic 2000 gallon tank uphill from the well set up with a blind knockout. A new turnaround has recently been built at the entrance of the lease road.
2040729398 2012-08-23 Final Restoration No Violations A follow-up inspection conducted with Mr. Brandon Mitchell revealed non-compliance. Mr. Clayton King had failed to meet the required deadline stated within the Compliance Notice. Therefore, on 7/30/2012, at 10:49 AM, Mr. King was contacted by telephone and agreed to complete the Final Restoration by 9/1/2012.
2075442622 2007-12-11 Production Wells No Violations Stopped by well location today. The well is capable. There is nobody on location and no evidence of brine being hauled. Brine tank on top of hill is full.
2097635800 2008-01-08 Production Wells No Violations Well has pump jack and is capable of production. Possible use of well for brine production. No change in road and gravel. Appears not using at this time. Well not pumping.
31168779 2012-4-3 0:00:0 FR No Violations
413706023 2011-8-4 0:00:0 PB No Violations
590187312 2012-10-5 0:00: FR No Violations
662952380 2008-7-15 0:00: PW No Violations
727213507 2008-3-31 0:00: PW No Violations
974308115 2008-6-19 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0031168779 US-OH-123246 2012-04-26 Failure to complete final restoration within six months