Well ID: 34-099-23060 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.1,"lon":-80.56,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Coitsville Township | |
Operator Name: BOCOR HOLDINGS, LLC | |
Well Pad ID: | |
Farm/Lease Name: WILLIAMS UNIT | |
License Status: Producing | |
License Date: 2007-08-28 | |
Spud Date: 2007-10-15 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-10-21 | |
Well Total Depth: 5607.00 ft | |
Configuration: Vertical | |
Latitude: 41.100000 | |
Longitude: -80.560000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-08-28 | Proposed Formations:CLINTON/MEDINA, Issued Date:8/28/2007, Expired Date:8/27/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-10-21 | |
Reached Total Depth | 2007-10-21 | |
Completion Report Received | 2007-11-28 | |
Construction Permit Expires | 2008-08-27 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-02-22 | 5371 | 5449 | 74 |
2008-02-22 | 5531 | 5539 | 17 |
5371 | 5449 | 74 | |
5531 | 5539 | 17 | |
5371 | 5449 | 74 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 0 | |||
H2O | 0 | 82780 Gal | 60000 | SINGLE RESERVOIR PRESSURES AND FRAC VOLUMES REPORTED FOR FRACS OF MEDINA AND CLINTON SANDSTONES |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
0 | 0 | 0 | ||
2008 | BOCOR HOLDINGS, LLC | 13049.00 | 0.00 | 365 |
2009 | BOCOR HOLDINGS, LLC | 8892.00 | 0.00 | 365 |
2010 | BOCOR HOLDINGS, LLC | 6591.00 | 0.00 | 365 |
2011 | BOCOR HOLDINGS, LLC | 5375.00 | 0.00 | 365 |
2012 | BOCOR HOLDINGS, LLC | 6104.00 | 36.00 | 366 |
2013 | BOCOR HOLDINGS, LLC | 4041.00 | 0.00 | 365 |
2014 | BOCOR HOLDINGS, LLC | 3061.00 | 0.00 | 365 |
2015 | BOCOR HOLDINGS, LLC | 3694.00 | 0.00 | 370 |
2016 | BOCOR HOLDINGS, LLC | 2938.00 | 29.00 | 365 |
2017 | BOCOR HOLDINGS, LLC | 2440.00 | 0.00 | 365 |
2018 | BOCOR HOLDINGS, LLC | 2071.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | BOCOR HOLDINGS, LLC | Brine | 0 | 365 |
2009 | BOCOR HOLDINGS, LLC | Brine | 108 | 365 |
2010 | BOCOR HOLDINGS, LLC | Brine | 70 | 365 |
2011 | BOCOR HOLDINGS, LLC | Brine | 160 | 365 |
2012 | BOCOR HOLDINGS, LLC | Brine | 70 | 366 |
2013 | BOCOR HOLDINGS, LLC | Brine | 0 | 365 |
2014 | BOCOR HOLDINGS, LLC | Brine | 85 | 365 |
2015 | BOCOR HOLDINGS, LLC | Brine | 0 | 370 |
2016 | BOCOR HOLDINGS, LLC | Brine | 0 | 365 |
2017 | BOCOR HOLDINGS, LLC | Brine | 0 | 365 |
2018 | BOCOR HOLDINGS, LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2131390308 | 2011-1-31 0:00: | PW | No Violations | |
-904205986 | 2007-10-18 0:00 | DD | No Violations | |
0904205986 | 2007-10-18 | Drill / Deepen / Reopen | No Violations | I preformed a rig inspection. Pit liner was in good shape. The drilling depth was 3905. CAPSTAR had a hole in there 3 1/2 drill pipe. They were waiting on orders. There were no violations at this time. |
1188679078 | 2007-10-16 | Drill / Deepen / Reopen | No Violations | I performed a rig inspection. Pit liners in good shape. There were no violations at this time. |
1192618073 | 2007-10-16 | Drill / Deepen / Reopen | No Violations | I witnessed the running and cementing of the surface casing. I found no violations at this time. |
1193160380 | 2007-10-23 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. Pit liners in good shape with the fluid level 2 foot down from the top. Drilling equipment is gone. This well does not pass preliminary restoration. |
1196192343 | 2007-11-27 | Preliminary Restoration | No Violations | I preformed a preliminary restoration status check. The drilling pits are closed. The drilling equipment is gone. The debris is gone. Still top soil piles on the edge of the location. The tank battery is in good shape. ID sign is posted. This well does not pass preliminary restoration |
1204747049 | 2008-03-05 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. Both the wellhead and the tank battery were GPSd. There was a fence around the tank battery and around the wellhead. A locked gate was also installed at the 616/lease road entrance. The drilling pits were closed. The debris was gone. The location was leveled but the top soil piles were still there. This well does not pass preliminary restoration. |
1214423191 | 2008-06-25 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. I GPSd the well and the tank battery. The pits are closed and the rig is gone. The debris is hauled away and vegetation is growing. The ID sign is posted. This well has PASSED PRELIMINARY RESTORATION. |
2131390308 | 2011-01-31 | Production Wells | No Violations | I performed a random field inspection. I GPSd both the tank battery and the wellhead for the first time. I continued my walk around both the wellhead and the tank battery. This inspection satisfies 1501:9-9-05. There were no violations at this time. |
For data sources see[9]