Well Details

Well ID: 34-111-24610
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Salem Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001274
Farm/Lease Name: PITTMAN
License Status: Producing
License Date: 2015-08-14
Spud Date: 2015-08-17
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2015-11-19
Well Total Depth: 24578.00 ft
Configuration: Horizontal
Latitude: 39.770000
Longitude: -80.920000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-08-14 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:8/14/2015, Expired Date:8/13/2017 12:00:00 PM, Drilling unit acres:578.266, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2015-11-19
Correction to Well 2016-12-30 CHANGE TARGET/TAKEPOINT/ACREAGE AS-DRILLED PLAT RCVD 12/5/16-ALE.
Completion Report Received 2017-03-01
Construction Permit Expires 2017-08-13
Record Last Modified 2017-10-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-03-01 11086 24441 0
11086 24441 0
11086 24441 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/11/2016 11/14/2016 10395 31,050,400.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HYDROCHLORIC ACID - 15% Halliburton Solvent Listed Below Listed Below 0 0 0
SAND-COMMON WHITE - 100 MESH Halliburton Proppant Listed Below Listed Below 0 0 0
FDP-S1225-15 Halliburton Surfactant Listed Below Listed Below 0 0 0
Ethylene oxide 75-21-8 0.01 0.00000033 1
Alcohols, C12-13, ethoxylated 66455-14-9 30 0.00001202 346
Propargyl alcohol 107-19-7 10 0.00003339 100
Ethoxylated alcohols Proprietary 30 0.00009951 298
Alcohols, C12-16, ethoxylated 68551-12-2 5 0.00001937 58
Hydrochloric acid 7647-01-0 15 0.0648377 194166
Methanol 67-56-1 60 0.000199022 596
Olefins Proprietary 5 0.00004007 120
Acetic acid 64-19-7 60 0.000481526 1442
Acetic anhydride 108-24-7 100 0.000802098 2402
Crystalline silica, quartz 14808-60-7 100 13.0922 39,206,400.0
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 30 0.00009951 298
Glycerine 56-81-5 5 0.00001937 58
Fatty acids, tall oil Proprietary 30 0.00009951 298
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 86.474 258,959,000.0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.432637 1,295,590.0
SAND-PREMIUM WHITE-40/70 Halliburton Proppant Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2016-11-16 H2O 0 510214 Gal 609996 Halliburton STAGE 1/67

36 SHOSTS STAGES 2-66 SEE IMAGES

2016-11-14 H2O 15 453957 Gal 598919 Halliburton STAGE 67/67

36 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 ECLIPSE RESOURCES I LP 397270 0 22
2017 ECLIPSE RESOURCES I LP 6823083 0 355
2018 ECLIPSE RESOURCES I LP 1257898 0 341
2019 ECLIPSE RESOURCES I LP 284373 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 ECLIPSE RESOURCES I LP Brine 12584 22
2017 ECLIPSE RESOURCES I LP Brine 69686 355
2018 ECLIPSE RESOURCES I LP Brine 6126 341
2019 ECLIPSE RESOURCES I LP Brine 1953 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1114919161 2015-8-19 0:00: CS No Violations 2.00
-1569602562 2016-11-23 0:00 CT No Violations 3.50
-2069872494 2016-11-7 0:00: CT No Violations 6.00
-459537875 2016-12-21 0:00 CT No Violations 3.00
-495750803 2015-11-10 0:00 DD No Violations 2.50
-808539242 2017-12-13 0:00 WR No Violations
0271451859 2016-11-02 Completion Testing No Violations

Inspection of the lined sumps constructed outside the well pad at global positioning system (GPS) coordinates 39.776921 -80.925483 revealed no fluid and at 39.776714 -80.925548 revealed a pH of 6 and chloride levels of 643 parts per million (ppm) and a pH of 6 and chloride levels of 997 parts per million (ppm). Field tests performed on the well pad near the working tanks at the GPS coordinates 39.775895 -80.925601 revealed a pH of 6 and chloride levels of 3296 ppm. ESM was then instructed by Mr. King to dig a collection sump near the working tanks to collect fluids to be removed until frac is completed in 10 days. Mr. Lois performed initial conductivity tests within the well site boundaries to determine the impacted areas from the release and to determine a plan for further testing.

0317835798 2017-01-05 Production Wells No Violations

- stage vertical separator. Also present included 4-400 barrel tanks within containment, 2 filter separators, 2 vertical scrubbers, 2 heater treaters and a gas combustor all shared with 34111245920000 Holliday A 1H, 34111245910000 Holliday A 3H, 34111245960000 Holliday B 7H and 34111246090000 Circosta 1H. Fluid found in pit #1 at global positioning system (GPS) coordinates 39.776921 -80.925483 was field tested and revealed a pH of 7 and chloride levels of 160 parts per million (ppm). Fluid in pit #2 at GPS coordinates 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 203 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 7 and chloride levels of 997 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of < 250 ppm. We met with Eclipse EHS Technician Ken Durst and completed walk around revealing containment was being removed. I instructed Mr. Durst to fill the mouse holes in accordance with OAC 1501:9-11-11 and to continue to pull fluids out of the sump until the levels are acceptable.

0428288831 2018-05-22 Production Wells No Violations Status check inspection found the well drilling and completion process now complete and the well producing through 2.875 production tubing with 2 manual and 2 emergency shut down in line valves present in the production flowline. Proper well identification is posted. Annular pressure monitoring is in place on the 13.375 and 9.625 well head sections with zero pressure on the 9.625 and 200 psi on the 13.375 well head sections. Production related equipment on site consists of 5 gas processing in line heaters and 5 sand trap separators along with a single glycol heater. The production fluid facility consists of 4 steel construction tanks of 400 barrel capacity situated inside a polymer lined steel containment area.
0459537875 2016-12-21 Completion Testing No Violations

-80.925483 was field tested and revealed a pH of 7 and chloride levels of 219 parts per million (ppm). Fluid in pit #2 at GPS coordinates 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 650 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 7 and chloride levels of 775 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of < 250 ppm.

0495750803 2015-11-10 Drill / Deepen / Reopen No Violations
0808539242 2017-12-13 Work Over Reconditioning No Violations Status check inspection found a snubbing unit work over rig set up on the well owned by Deep Well Service with a Quail Service Tools workover blow out preventer stack. The rig is fishing part of the 2.875 diameter production that was lost in the well bore curve between the depths of 10,361 and 11,071 . The company man on site indicated the well bore communicated with another well in the area being stimulated and there is sand in around the tubing string and they had to back the production string off down hole. They have made a clean out run down to the top of the lost string and stabilized the well bore with brine water. They are now pulling the workover string so they may put a fishing neck recovery tool onto the workover string to attempt the recovery process. Once they grab ahold of the lost string they will make an internal clean out run with a coil tubing unit so they can get downhole inside the tubing with wireline tools to free point the tubing. The service rig is situated on polymer containment.
0968629520 2017-03-28 Production Wells No Violations

- stage vertical separator. Also present included 4-400 barrel tanks within containment, 2 filter separators, 2 vertical scrubbers, 2 heater treaters and a gas combustor all shared with 34111245920000 Holliday A 1H, 34111245910000 Holliday A 3H, 34111245960000 Holliday B 7H and 34111246090000 Circosta 1H. Fluid found in pit #1 at global positioning system (GPS) coordinates 39.776921 -80.925483 was field tested and revealed a pH of 7 and chloride levels of 151 parts per million (ppm). Fluid in pit #2 at GPS coordinates 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 255 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 7 and chloride levels of 96 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of 139 ppm. Issues have been remediated and Compliance Notice is resolved.

0988068894 2016-12-13 Completion Testing No Violations

-80.925483 was field tested and revealed a pH of 7 and chloride levels of 236 parts per million (ppm). Fluid in pit #2 at GPS coordinates 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 569 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 7 and chloride levels of 412 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of < 250 ppm.

1114919161 2015-08-19 Casing String Witnessed No Violations The said well was spudded on 08/17/2015 by Precision Rat Hole with a 30 x 120 conductor borehole being drilled and 120 of 24 .375 wall 94.62# pound per foot weld connection casing being ran. Universal Well Service is the cement contractor on location to cement the casing using 320 sacks of class A-3% calcium .25 pound per sack loss circulation material with the pipe capacity being displaced with 53 barrels of fresh water and 10 barrels of 6% gel prior to cementing with good cement witnessed to surface. Inspector Brian Sefcik accompanied me on this day.
1446055963 2015-10-25 Casing String Witnessed No Violations On site to witness running and cementing of 13.375 surface casing, H&P rig 531 on site and they drilled 17.5 hole to 1774 and ran 1723 of 13.375 and it was cemented in place with 1390 sacks of Class A cement with 32 bbl. Returns to surface

Note: Measurements are from KB not ground level and sub structure is 30tall.

1477938525 2016-10-31 Completion Testing Violations Noted On the day of my inspection following up on a reported release on the pad from 10/30/16 at 0730, I met with EHS Supervisor Bruce Carpenter and EHS Technician Tyler Bryant. Mr. Carpenter stated that a Crescent employee was filling a 500 barrel produced water tank with fresh water and overflowed the tank by 200 barrels. The secondary containment failed resulting in the water flowing across the pad to the northwest side and an unknown amount of water breaching the well pad. Field tests performed on puddles found outside the well pad at global positioning system (GPS) coordinates 39.776921 -80.925483 and 39.776714 -80.925548 revealed a pH of 6 and chloride levels of 643 parts per million (ppm) and a pH of 6 and chloride levels of 843 ppm respectively. Field tests performed on the well pad near the working tanks at the GPS coordinates 39.775895 -80.925601 revealed a pH of 6 and chloride levels of 4933 ppm. Inspection of the north and west sump valves revealed that they appeared to be shut but the outlets could not be found. Owner/Operator tried to locate the outlets by unsuccessfully excavating. At 12:20 ODNR Engineering Tech Andy Thomas and ODNR Emergency Response Tech Nathan Lane arrived and completed walk around. Owner/Operator has removed 3 roll off boxes of contaminated materials to be disposed of in a proper landfill. Owner/Operator shall supply ODNR copies of the manifests for the disposal and continue to excavate the north and west sump drains to verify the valves are closed. Owner/Operator excavated two collection sumps which will be lined to collect water seeping from the pad. Owner/Operator shall continue to test, collect and dispose of contaminated waters and soils from the pad to ensure that all oilfield contaminates are removed and chloride levels are less than 250 ppm.
1477949314 2016-10-30 Completion Testing No Violations On this day I was contacted by Bruce Carpenter with Eclipse at 13:57 pm and informed they had ran a 500 barrel tank over while pumping fresh water into the tank with a reported 5 barrels of product spilled inside containment and a undetermined amount seeping through holes in the containment. Upon further questioning I was informed some well related product was inside the tank. I informed Mr. Carpenter to notify the divisions one call number and contacted my Supervisor. The producer currently has contractors on site stimulating the well.
1569602562 2016-11-23 Completion Testing No Violations

-80.925483 was field tested and revealed a pH of 7 and chloride levels of 153 parts per million (ppm). Fluid in pit #2 at 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 1004 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 7 and chloride levels of 720 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of < 250ppm. I completed walk around with Eclipse Consultants Will Ochampaugh and Cristo Giannareas revealing that secondary containment was in place and in good shape and production equipment was being installed at the south end of the well pad.

1595843237 2016-12-07 Drill / Deepen / Reopen No Violations The purpose of my inspection today is to follow up on a compliance notice -1477938525. During my inspection I witnessed Deep Well Services was onsite drilling out the 3411124592 Holliday A 1H. Field test in pit number one at the global positioning system coordinates 39.776921 -80.925483 found chloride levels of 46 parts per million. Field test in pit number two at the global positioning system coordinates 39.776714 -80.925548 found chloride levels of 275 parts per million.
1667245715 2016-11-29 Completion Testing No Violations

-80.925483 was field tested and revealed a pH of 6 and chloride levels of 45 parts per million (ppm). Fluid in pit #2 at GPS coordinates 39.776714 -80.925548 was field tested and revealed a pH of 6 and chloride levels of 296 ppm. The fluid found in the northwest sump was field tested and revealed a pH of 6 and chloride levels of 371 ppm. Various puddles were field tested on the well pad revealing a pH of 7 and chloride levels of < 250ppm. I completed walk around with EHS Supervisor Bruce Carpenter and EHS Technician Ken Durst.

1730867276 2016-11-15 Completion Testing No Violations

-80.925483. Fluid in pit at 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 919 parts per million (ppm). No fluid was found on the well pad.

2007509170 2017-03-21 Preliminary Restoration No Violations Preliminary Restoration found the area affected by the well pad construction meets ORC 1509.072 with vegetation established and erosion control in place. The lease road is in good repair and stoned. The location entry point is posted with the owners contact information. The location is fenced with chain link fence. There is a total of 6 wells on the pad 5 of which are complete and all 6 have identification posted. The said well has a casing and tubing well head in place and is equipped with tubing head valves and B section cross valves. There is a Hydraulic operated electrically controlled emergency valve on the tubing head output flow line that has shut down points at the well head and production facility along with at the well pad entry point. Also on location downstream from the well head is a sand trap and line heater and then a mechanical separator. The mechanical separator sends the processed fluid to the production facility that consists of 4 steel construction 400 barrel capacity production tanks located inside a polymer lined steel containment area. There is also 2 dehydration units on location that service the 6 total line heaters on the pad.
2069872494 2016-11-07 Completion Testing No Violations

-80.925483. Fluid in pit at 39.776714 -80.925548 was field tested and revealed a pH of 7 and chloride levels of 561 parts per million (ppm). No fluid was found on the well pad. Mr. Carpenter stated that Eclipse will present a plan for remediation late Wednesday or early Thursday for ODNR to approve prior to commencement.

271451859 2016-11-2 0:00: CT No Violations 8.00
317835798 2017-1-5 0:00:0 PW No Violations 2.00
428288831 2018-5-22 0:00: PW No Violations 0.30
968629520 2017-3-28 0:00: PW No Violations 2.00
987233843 2020-5-22 0:00: PW No Violations 1.00
988068894 2016-12-13 0:00 CT No Violations 3.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1477938525 US-OH-113666 2016-11-25 Pollution and contamination

For data sources see[10]