34-111-24633

Well Details

Well ID: 34-111-24633
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Ohio Township
Operator Name: EQUINOR USA ONSHORE PROPERTIES
Well Pad ID: US-OH-001345
Farm/Lease Name: BAUER NORTH
License Status: Producing
License Date: 2016-04-29
Spud Date: 2016-08-18
Spud Drilling Contractor: ORION DRILLING
Final Drill Date: 2016-11-12
Well Total Depth: 20810.00 ft
Configuration: Horizontal
Latitude: 39.720000
Longitude: -80.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-12-04 Proposed Formations:POINT PLEASANT, Issued Date:12/4/2015, Expired Date:12/3/2017 12:00:00 PM, Drilling unit acres:1042.37, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2016-04-29 Proposed Formations:POINT PLEASANT, Issued Date:4/29/2016, Expired Date:4/29/2018 12:00:00 PM, Drilling unit acres:1042.37, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2016-06-17 Unit change.
Reached Total Depth 2016-11-12
Correction to Well 2017-02-24 UPDATE TARGET/TAKEPOINT PER AS-DRILLED PLAT RCVD 1/10/2017-ALE
Completion Report Received 2017-11-15
Construction Permit Expires 2018-04-29
Change of Owner 2018-08-08 Operator changed from 9065, STATOIL USA ONSHORE PROPERTIES INC to 10187, EQUINOR USA ONSHORE PROPERTIES INC.
Record Last Modified 2018-08-08

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-12-12 10898 11073 48
2017-12-12 20524 20676 44
20524 20676 44
10898 11073 48
10898 11073 48

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/26/2017 07/01/2017 10409 16,428,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.99181 1,585,910.0
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
FDP-S1176-15 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
Cla-Web(TM) II Halliburton Clay Stabilizer Listed Below Listed Below 0 0 0
AccessFrac LT material Halliburton Diverter Listed Below Listed Below 0 0 0
Acetic anhydride 108-24-7 100 0.00818107 13082
Ethanol 64-17-5 1 0.000356372 570
Ammonium compound Proprietary 30 0.00007100 114
Citric acid 77-92-9 60 0.00565918 9050
Acetic acid 64-19-7 60 0.00490864 7849
Glutaraldehyde 111-30-8 30 0.0106912 17096
Polyacrylate Proprietary 30 0.0298519 47734
Amine salts Proprietary 1 0.00000260 5
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00178186 2850
Hydrochloric acid 7647-01-0 15 0.13449 215058
Sodium chloride 7647-14-5 5 0.00497768 7960
Propargyl alcohol 107-19-7 10 0.00006766 109
Phosphoric acid 7664-38-2 0.1 0.00003564 57
Castor oil, ethoxylated 61791-12-6 5 0.00497531 7956
Sobitan, mono-9-octadececenoate, (Z) 1338-43-8 5 0.00497531 7956
Hydrotreated light petroleum distillate 64742-47-8 30 0.0298519 47734
Olefins Proprietary 5 0.00008119 132
Ammonium chloride 12125-02-9 5 0.00497531 7956
Amine Proprietary 0.1 0.00000024 1
Quaternary amine Proprietary 1 0.00000473 8
Ethoxylated alcohols Proprietary 30 0.000202975 325
Chlorine compound Proprietary 30 0.00007100 114
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 30 0.000202975 325
Polylactide resin Proprietary 100 0.000562849 900
Crystalline silica, quartz 14808-60-7 100 13.3649 21,370,500.0
9-Octadecenamide, n,n-bis-2(hydroxy-ethyl)-,(Z) 93-83-4 5 0.00497531 7956
Fatty acids, tall oil Proprietary 30 0.000202975 325
Methanol 67-56-1 60 0.000455841 730
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 85.5843 136,850,000.0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2017-04-26 H2O 15 365488 Gal 453960 Halliburton STAGE 1/49

STAGES 2-49 SEE IMAGES

2017-07-01 H2O 15 333524 Gal 438940 Halliburton STAGE 49/49

STAGES 2-48 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 STATOIL USA ONSHORE PROPERTIES 1687513 0 82
2018 EQUINOR USA ONSHORE PROPERTIES 4823175 0 354
2019 EQUINOR USA ONSHORE PROPERTIES 516127 0 88

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 STATOIL USA ONSHORE PROPERTIES Brine 10236 82
2018 EQUINOR USA ONSHORE PROPERTIES Brine 34843 354
2019 EQUINOR USA ONSHORE PROPERTIES Brine 4746 88

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1272008449 2016-8-25 0:00: DD No Violations 4.00
-1682479911 2017-8-15 0:00: WR No Violations 0.50
-620901631 2017-6-20 0:00: CT No Violations 1.50
-697774141 2017-9-25 0:00: PW No Violations 0.50
0070856007 2017-02-08 Preliminary Restoration No Violations Preliminary Restoration status check inspection found the area affected by the well pad construction meets ORC 1509.072 with erosion control in place and vegetation established. No pits were erected during the drilling process. The well has been drilled and not stimulated and there is no production tanks in place. The well pad is fenced and gated with a lock on the gate.
0620901631 2017-06-20 Completion Testing No Violations Status check inspection on the well completion process found the 5.5 production casing was perforated and a cement squeeze job administered to the annular side of the well bore. A casing patch was set over the perforations. Halliburton Pressure Pumping and Allied Wireline will move in and complete the well stimulation in the next 10 days.
0697774141 2017-09-25 Production Wells No Violations On the day of my inspection, I accompanied ODNR Inspector William Stolarik. Please reference his comments for a detailed report. Upon inspection we found Fesco on location, (2) gas busters, and (6) 500 barrel horizontal steel tanks within containment. Bill was contacted on September 23, 2017 about a slight leak from containment surrounding the 500 barrel tanks.
0819256043 2019-04-04 Production Wells No Violations On this day, I am accompanied by ODNR Inspector Rick Brown. I found the pad gated with signage at the entrance. There are (2) producing wells, (2) gas processing units, (2) 400-barrel steel production tanks within steel containment, and an Emergency Shutdown (ESD) button is present at the pad entrance. Concrete barriers surround the perimeter of the wellheads. Each well has identification and annular pressure monitoring devices equipped. The 9.625 inch diameter intermediate casing has a pressure of 20 pounds per square inch (psi), and the 13.375 inch diameter surface casing has a pressure of 0 psi. The production records are current.
1056545683 2017-09-25 Production Wells No Violations Status check inspection as a follow up to a reported fluid spill on 09/23/2017 by Company man Darrin Galisky who indicated approximately 3 barrels of production fluid had escaped off polymer containment through a hole in the containment. It was observed on this day that a total of 4 steel tanks of 500 barrel capacity were situated on the well pad providing support to the Fesco Company flow back services who were flowing back the (2) wells on the pad during their initial stages of production. One of the flow back tanks had not had the side dome style access port closed before being placed into surface and was leaking and also placed in a way as to limit access to close the tank port hole. The company has recovered any standing product from the well pad.
1198142473 2016-11-30 Completion Testing No Violations On site inspection to check on the 5.5 production string cement job evaluation. Well Service Group is rigging up a tubing snubbing work over unit and preparing to run in the hole with a 2.875 workover string. The workover well head assembly consists of a manual and hydraulic master valves and a Blow out prevention stack consisting of 23sets of pipe rams and one set of blind shear rams. The company will run in the hole and drill out any cement inside the 5.5 production casing down to the float shoe and then pull the workover string and run a casing bond log to determine if any of the 5.5 annular side is open.
1272008449 2016-08-25 Drill / Deepen / Reopen No Violations The inspection today revealed that the well is drilling ahead. The company is currently drilling with a 17.5 inch diameter drill bit and is at the measured depth of 2227 feet. The company has encountered a volume of oil and gas around 1960 feet and has stopped drilling to fill the bore hole with fluid. Once the company has the amount of oil and gas level controlled they will resume drilling to the first intermediate casing point at 2500 feet.
1471864921 2016-08-22 Casing String Witnessed No Violations On site inspection to witness the surface casing cement job found Orion Drilling Polaris rig 14 on location with a 24 surface borehole drilled to 428 and 372 of 20 94 lb/ft J-55 buttress thread casing ran. Halliburton cement service conducted the inner string cement job by pumping 320 sacks of class A -
1472147789 2016-08-25 Drill / Deepen / Reopen No Violations Status check inspection on the well drilling progress found Orion Drilling Polaris rig 14 on location currently drilling the 17.5 production borehole at a measured depth of 2,027.The company has encountered a large volume of gas and oil at 1,960 and has stopped drilling to load the borehole with fluid and will complete the 17.5 well bore on fluid. Statoil Drilling Superintendent Cameron LaVigne was on location and we discussed their proposed amended casing design; Mr. LaVigne indicated they would be contacting the Divisions permitting section with amended design proposals for any wells drilled moving foreword. Mr. LaVigne was also informed that the company was required to notify the Division and the local emergency responders when flaring.
1478953587 2016-11-11 Drill / Deepen / Reopen No Violations The company man on site Jack Garcia notified me by phone at 17:38 pm of a failed 5.5 casing cement job. Mr. Garcia indicated that the 8.5 well bore was drilled to a measured depth of 20,810 and 5.5 casing was ran to bottom with out issue with a flotation collar set in the string at 10,175 allowing the 5.5 casing to be loaded with fluid from 10.175 to surface. It was indicated that upon the landing of the casing internal pressure was increased and the circulation disc burst in the flotation collar and circulation established without incident. The casing cement job was executed and 549 barrels of cement pumped successfully, however during cement displacement the circulation pressure increased at 215 barrels out of a total of 438 barrels of fluid into displacement with cancellations showing the cement plug stuck in the flotation collar. The annular estimated top of cement by calculation is at 12,854 in the horizontal section with the horizontal curve being landed at 11,020 leaving a estimated 1,834 of open hole in the horizontal lateral section. The company man indicated the rig would wait on the cement to cure before demobilizing the drilling rig. Instructions were given to secure the well head assembly and install pressure gauges accordingly, the company will submit a plan to the Division before bringing in a service rig to repair the well bore.
1480948087 2016-12-05 Completion Testing No Violations Status check inspection to witness the well bore 5.5 diameter production casing cleanout. Well Service Group has a tubing snubbing unit on location and is drilling cement out of the inside of the 5.5 with cement being encountered at a measured depth of 10,165 and the company currently drilling at 16,400 going to 20,810. A bond log will be ran once the cement inside the casing is drilled out.
1495724126 2017-05-25 Completion Testing No Violations On site status check to witness the well remediation process. Upon inspection it was observed that the well is equipped with a FMC Technologies B section well head pressure rated a 10,000 psi (pound per square inch) rated working pressure. On top of the B section well head is the workover completion blow out prevention well control stack that consists of a set of pipe rams then a set of shear rams followed by a flow cross fluid release section and then another set of pipe rans topped off with a set of hydraulically controlled annular bags, all rated and pressure tested to at 15,000 psi rated working pressure. Internally the well is equipped with 5.5 diameter production casing set to a total measured depth of 20.791 and a 9.625 diameter intermediate string set to a measured depth of 9,703. The company has indicated they have stimulated 35 of 49 proposed stages to be stimulated and has stopped stimulation to repair the annular of the 5.5 diameter production casing by the means of a cement squeeze job. Key Energy has a service rig over the well and Horizontal Wireline service is Rigging up on the well to begin the preparation work of the 5.5 diameter 23 pound per foot production casing. At this point Horizontal Wireline has set a 10,000 pound rated working pressure cast iron bridge plug at a depth of 13,691 and is preparing to set a second cast iron plug for isolation purposes at a depth of 10,000. Upon completion of setting the 2nd plug 6 perforations will be shot in the 5.5 diameter casing at 10,020. After the perforations are shot in the casing Halliburton Pumping service who is also on location will attempt to establish circulation through the 5.5 diameter casing out the perforations to surface on the annular of the casing. At the point a achieved rate and pressure is established the wireline service will set a Magnum Oil Tool intervention less Cement Retainer at a depth of 9,800 and a annular squeeze job with be conducted on the 5.5 casing.
1496171901 2017-05-30 Completion Testing No Violations

-110. There is a mill on the bottom of the tubing to mill the casing patch out. The Bottom hole assembly is as follows: 1--

1516203691 2018-01-17 Production Wells No Violations Status check inspection on the current well status found the well drilling and completion process now complete. The well is in production and the master valve open. Annular pressure monitoring is present and in place. Well identification is present on each of the (2) wells present on location. Each well is selling into a gas processing unit which is located on location. Also present on location is a production fluid storage area consisting of (2) steel construction 400 barrel capacity tanks situated inside a steel containment barrier with a polymer liner.
1582640062 2020-1-27 0:00: PW No Violations 1.20
1682479911 2017-08-15 Work Over Reconditioning No Violations Status check inspection on the well completion process found the well stimulation and completion process is complete and Roc Water flow back service standing by to initiate the initial well production flow back. The Company man on site was directed to notify the company to monitor all annular pressures and report any abnormal pressures to the Division. The Company man was also advised all annular pressures were to be continually monitored during the well completion process.
678097958 2020-8-13 0:00: PW No Violations 1.30
70856007 2017-2-8 0:00:0 PL No Violations 1.10
819256043 2019-4-4 0:00:0 PW No Violations 0.40

For data sources see[10]