34-131-20092

Well Details

Well ID: 34-131-20092
Loading map...
Country: United States
State: Ohio
County: Pike
Municipality: Marion Township
Operator Name: KNOX ENERGY INC.
Well Pad ID:
Farm/Lease Name: SULLIVAN E & M
License Status: Final Restoration
License Date: 2011-12-05
Spud Date: 2007-10-30
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2007-11-02
Well Total Depth: 915.00 ft
Configuration: Vertical
Latitude: 39.030000
Longitude: -82.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-09-05 Proposed Formations:OHIO SHALE, Issued Date:9/5/2007, Expired Date:9/4/2008 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-11-02
Reached Total Depth 2007-11-02
Completion Report Received 2008-01-24
Change of Owner 2009-08-11 Operator changed from 8228, PAXTON MADISON LLC to 6295, KNOX ENERGY INC.
APP 2010-07-01 Proposed Formations:OHIO SHALE, Issued Date:7/1/2010, Expired Date:7/1/2011 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
APP 2011-12-05 Proposed Formations:CLINTON, Issued Date:12/5/2011, Expired Date:12/4/2013 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2012-08-29
Construction Permit Expires 2013-12-04
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-03-24 540 545 20
2008-03-24 484 489 20
484 489 20
540 545 20
732 737 20
789 802 52
830 845 40
484 489 20
2008-03-24 732 737 20
2008-03-24 830 845 40
2008-03-24 789 802 52

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 8 10 Mscf 21800 STAGE 4 OF 4
N2 8 19 Mscf 30000 STAGE 1 OF 4
N2 8 11 Mscf 8900 STAGE 2 OF 4
N2 8 2 Mscf 19800 STAGE 3 OF 4

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAXTON MADISON LLC 0.00 0.00 0
2009 PAXTON MADISON LLC 0.00 0.00 0
2010 KNOX ENERGY INC. 0.00 0.00 0
2011 KNOX ENERGY INC. 0.00 0.00 0
2012 KNOX ENERGY INC. 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAXTON MADISON LLC Brine 0 0
2009 PAXTON MADISON LLC Brine 0 0
2010 KNOX ENERGY INC. Brine 0 0
2011 KNOX ENERGY INC. Brine 0 0
2012 KNOX ENERGY INC. Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1724395887 2010-1-14 0:00: PW No Violations
-639603841 2012-8-31 0:00: PB No Violations 3.20
-757731595 2008-1-11 0:00: PW No Violations
0047605764 2007-10-31 Drill / Deepen / Reopen No Violations Surface cement job. Spud date 10-30-07. TD 415 ran 388 of 8 cemented to the surface. Good circulation and cement returns to the surface.
0232768014 2010-03-08 Administrative Inspection No Violations Received call from Bill Mitton. 3:20pm Re: will get identification on wells this week. Will attempt to produce and work with the well this spring. Will be bringing a rig down. If not successful will plug the well while rig is in area.
0341631819 2015-03-03 Final Restoration No Violations Final Restoration requirements met.
0639603841 2012-08-31 Plug / Plug Back No Violations Witnessed casing being cut off 30 below grade. 5.5 casing was cemented back to surface. Cement inside 5.5 casing had dropped 24 7 from surface. 5.5 casing was filled with concrete to 30 below grade. Identification plate was placed on casing and casing buried.
0757731595 2008-01-11 Production Wells No Violations Production equipment has been installed. Electric service is in place and operating. Electric lines are either on poles or buried in conduit. Whole operation looks good. Well is not connected to production lines yet. They are in a testing phase right now.
1213628089 2008-06-05 Preliminary Restoration No Violations Well site has been reclaimed and pits filled in. Land is now being used for agriculture. Production equipment has been installed. Well needs identification.
1244689151 2012-08-16 Production Wells No Violations Well is permitted for plugging. Well is shut in with all valves closed. Surface casing annulus is open with no valves installed on wellhead. Well is disconnected from production lines and no production equipment is on location. Electric service line is disconnected. No gas was detected on gas meter during inspection. Accompanied by Morgan Button MRI 2.
1346177638 2012-08-27 Plug / Plug Back No Violations Knox Energy service rig on well. 5.5 casing full of fluid. Well started to kick off during disassembly of well head. Unable to rig up to swab. Huffman Bowers Water truck was sent to location. Water truck was connected to well. Flowed brine and gas into truck. Accumulated 20 barrels fluid in truck. Well pressure was constant and would not blow down. Shut in wellhead . Coordinate getting tubing and pit liner on location. Bottom plug scheduled for 8-29-12.
1346262602 2012-08-29 Plug / Plug Back No Violations Plug from total depth to surface inside 5.5 Production casing (cemented to surface). Accompanied by Morgan Button MRI2. Cement pumped through 1.5 tubing ran to 886. Pumped plugs in 200 foot intervals from 886 to surface. Good cement circulation to surface. Cement fell back and was filled back to surface. Verified that 5.5 casing was cemented to surface.
1346262629 2012-08-29 Plug / Plug Back No Violations Accompanied Jon Scott to location. Berry Well Services, Formation Cementing and Huffman Bower Water truck were already on location. Berry was rigged up and 1.5 inch production tubing was set at a depth of 886 feet. The bottom of the hole was tagged at a depth of 910 feet. It was agreed that cement was to be pumped in 200 feet stages from bottom to surface. After each stage of cement was pumped, tubing was lifted to the top of the last stage and pumping resumed to the next 200 feet interval. This continued until cement came to surface . Then plugging was ceased. Top dressing of cement was added to ensure complete cement coverage. Cement in lines was cleared with fresh water and disposed of beneath liner to the returns pit. Liquid from displacement in the well during plugging was also discharged in this lined pit.
1724395887 2010-01-14 Production Wells No Violations No identification. Well is not connected to a production line. A 2 line connected to the annulus has a meter with a chart along with two valves. Both valves are open. No gas flow was observed during inspection. A call was made to Bill Mitton (Knox Energy) Voice mail. Re: well status and that well needs identification.
232768014 2010-3-8 0:00:0 AM No Violations
341631819 2015-3-3 0:00:0 FR No Violations 1.30
47605764 2007-10-31 0:00 DD No Violations

For data sources see[9]