X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-24310

Well Details

Well ID: 34-151-24310
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Jackson Township
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: KIKO
License Status: Storage Well
License Date: 1986-09-15
Spud Date: 1986-10-12
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1986-11-06
Well Total Depth: 4540.00 ft
Configuration: Vertical
Latitude: 40.850000
Longitude: -81.430000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Stratigraphic Test 1986-09-15 Issued Date 9/15/86 Expired Date 9/15/87 Acres 0000000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04540 Proposed Drill Depth 04540
Original Spud 1986-10-12 STORAGE
Completed 1986-11-06 STORAGE
Reached Total Depth 1986-11-06 STORAGE
CO 1987-01-08 240 EAST OHIO GAS CO GeoDate 9/15/86
Completion Report Received 1987-01-20 STORAGE
Construction Permit Expires 1987-09-15 STORAGE
Record Last Modified 2017-02-15 STORAGE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4360 4433 34
4360 4433 34
4360 4433 34

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 750 Gal 0 FE
N2 0 680 Mscf 0
FOAM 0 0 0 75 QUAL FOAM FRAC..402 BW, 350 SX
H2O 0 402 Bbl 35000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 DOMINION EAST OHIO 0.00 0.00 0
2003 DOMINION EAST OHIO 0.00 0.00 0
2004 DOMINION EAST OHIO 0.00 0.00 0
2005 DOMINION EAST OHIO 0.00 0.00 0
2006 DOMINION EAST OHIO 0.00 0.00 0
2007 DOMINION EAST OHIO 0.00 0.00 0
2008 DOMINION EAST OHIO 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 DOMINION EAST OHIO Brine 0 0
2003 DOMINION EAST OHIO Brine 0 0
2004 DOMINION EAST OHIO Brine 0 0
2005 DOMINION EAST OHIO Brine 0 0
2006 DOMINION EAST OHIO Brine 0 0
2007 DOMINION EAST OHIO Brine 0 0
2008 DOMINION EAST OHIO Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-270118651 2018-2-16 0:00: SO No Violations 0.50
-833622959 2017-10-5 0:00: SO No Violations
0000PL5104 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0270118651 2018-02-16 Storage Well No Violations I did a status check inspection for this storage well. The well is equipped with a plunger-lift system, a vertical separator and a meter. The diked tank battery consist of a steel tank. The well is legibly identified. No compliance issues are cited at this time.
0833622959 2017-10-05 Storage Well No Violations At the time of this inspection, the well site is equipped with a plunger lift assembly that has been converted to an open flow well:



The lease access is stable and drivable. No violations were observed.

1024520502 2016-06-07 Storage Well No Violations I conducted a status check on this well. The well site is equipped with:



The lease access is stable and drivable. No violations found.

1230686524 2015-05-28 Storage Well No Violations I conducted a status check on this well. The well is equipped with a plunger lift unit. There is a flow gate valve plumbed with a 2.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) tank drains on the storage tank and they are secured with valves and bull plugs in place. There is a mechanical separator and a sales line with a meter box. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable and drivable. No violations found.
1412344978 2014-09-26 Storage Well No Violations I inspected Dominion East Ohio Gas storage well #3838. The well is equipped with a master gate valve and a side gate valve with a plunger lift system which was inspected by a third party company 8/2014. There was a sales line with a separator. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bull plugs in place. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stoned and drivable. No violations found.
1588002251 2020-4-27 0:00: SO No Violations 0.40
1620302465 2019-9-23 0:00: SO No Violations 0.50
PL5104 PL No Violations

For data sources see[9]

References