If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-163-20895 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.24,"lon":-82.32,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Knox Township | |
Operator Name: CLEARWATER OPERATIONS LLC | |
Well Pad ID: | |
Farm/Lease Name: MCGLAUGHLIN LAURA | |
License Status: Producing | |
License Date: 1987-07-08 | |
Spud Date: 1987-08-17 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: 0.00 ft | |
Configuration: Vertical | |
Latitude: 39.240000 | |
Longitude: -82.320000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-07-08 | 566 GRIM PAUL A GeoDate 7/8/87 |
Oil and Gas | 1987-07-08 | Issued Date 7/8/87 Expired Date 7/7/88 Acres 0132440 Tool Type RTAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1987-08-17 | PERMIT EXPIRED. |
Construction Permit Expires | 1988-07-07 | PERMIT EXPIRED. |
Change of Owner | 2001-11-21 | Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP. |
Change of Owner | 2011-02-28 | Operator changed from 5755, CHIEFTAIN ENERGY CORP to 6227, HOUGHTON INVESTMENTS, L.L.C. |
Change of Owner | 2016-08-01 | Operator changed from 6227, HOUGHTON INVESTMENTS LLC to 7077, D T ATHA INC |
Change of Owner | 2018-07-31 | Operator changed from 7077, RIVER VALLEY ENERGY INC to 10184, CLEARWATER OPERATIONS LLC |
Record Last Modified | 2018-07-31 | PERMIT EXPIRED. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1996 | GRIM PAUL A | 0.00 | 57.00 | 365 |
1997 | GRIM PAUL A | 0.00 | 263.00 | 365 |
1998 | GRIM PAUL A | 180.00 | 0.00 | 365 |
1999 | GRIM PAUL A | 0.00 | 0.00 | 365 |
2000 | GRIM PAUL A | 0.00 | 0.00 | 365 |
2001 | GRIM PAUL A | 0.00 | 26.00 | 365 |
2002 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2003 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2004 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2005 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2006 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2007 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2008 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2009 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2010 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2011 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2012 | HOUGHTON INVESTMENTS LLC | 0.00 | 471.00 | 366 |
2013 | HOUGHTON INVESTMENTS LLC | 0.00 | 363.00 | 365 |
2014 | HOUGHTON INVESTMENTS LLC | 0.00 | 376.00 | 365 |
2015 | HOUGHTON INVESTMENTS LLC | 0.00 | 312.00 | 365 |
2016 | HOUGHTON INVESTMENTS LLC | 0.00 | 158.00 | 365 |
2017 | RIVER VALLEY ENERGY INC | 0.00 | 322.00 | 365 |
2018 | RIVER VALLEY ENERGY INC | 0.00 | 207.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1910443512 | 2008-2-7 0:00:0 | AM | No Violations | |
-982764342 | 2008-10-3 0:00: | PW | No Violations | |
0231894403 | 2008-06-30 | Administrative Inspection | No Violations | A telephone message was left for Mr. Doug Kitchen regarding the status of the McGlaughlin, Phillips and Tedric wells. |
0343195994 | 2008-10-22 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. During the inspection , it was noted that new identification has been placed at the well. The valves were observed to be closed and the well is still leaking gas. |
0397144601 | 2008-02-14 | Production Wells | Violations Noted | A complaint was received alleging that the McGlaughlin wells are not in production. The complainant also requested a different well operator. The complainant was contacted by telephone and informed that an inspection would be conducted on the McGlaughlin wells however, we can not provide a different operator. An inspection revealed that this well is idle. The pump jack has been removed from this well. Rods and tubing were observed in the well. A section below the stuffing box is bent, which may have occurred when the pump jack was removed. Records indicate that the last 2 years of production was 1998 and 2001. Moreover, it was noted that this well was leaking gas at the time of the inspection. Flowline also observed to be cut. A creek was found to be located on both sides of the well. The original lease road near McGlaughlin #8 location appears to have been washed out by the creek. Also noted was that identification was missing and the lease road will need to be graded. Several rills were observed along the lease road. |
0885721932 | 2008-06-30 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. This case will be handed over to management. |
0982764342 | 2008-10-03 | Production Wells | No Violations | A follow-up inspection was conducted with Mr. Doug Kitchen, Chieftain Energy, revealed non-compliance. Mr. Kitchen states that he will provide a production plan for wells with NOVs located in Vinton County. |
1219413706 | 2008-02-27 | Administrative Inspection | No Violations | Informed Chieftain Energy employee of the complaint received and inspection results. He was informed that the well is located next to a creek, missing ID. A rod and tubing was also observed to be bent and gas leaking from the well. Plastic flowline observed cut. The employee states that he would pass this information along to his boss, Mr. Doug Kitchen. |
1220539946 | 2008-09-04 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. Valves are closed, flowline is cut, and section of tubing and rod is bent. As a result, gas is being released. No work has been done to resolve violations. Photographs were obtained from this inspection. |
1237211006 | 2009-03-03 | Production Wells | No Violations | A follow-up inspection revealed compliance. |
1881317718 | 2008-11-26 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. The well is not equipped with a pump jack and the top joint of tubing below pumping tee remains bent. Natural Gas was not observed leaking during this inspection. A Chieftain Energy contractor, Mr. Ron McBride, had stated that by tightening up the well head resulted in no more leakage. During the inspection, it was noted that new black plastic flowline has been installed. The flowline was observed connected to the casing located on the opposite side of an existing plastic line that had been cut. This particular flowline had contained a regulator. The casing valve, on new installation side, was found open. A valve observed on the flowline that was partially buried was found closed. The new flowline is routed to a location below the tank battery and tied into an existing line. Chieftain Energy states that this well will now provide house gas instead of Permit No. 532. Mr. Doug Kitchen has stated that this well would continue to provide gas but also be pumped to produce oil. |
1910443512 | 2008-02-07 | Administrative Inspection | No Violations | A conversation was held with Mr. Doug Kitchen by telephone regarding the complaint received by the Division. He states that if need be, they will continue to plug wells in Vinton County. |
2052124953 | 2008-12-11 | Administrative Inspection | No Violations | Spoke with Mr. Ron McBride, Chieftain Energy contractor, in person regarding this well. Mr. McBride was informed that this well is not in-compliance and does not meet the definition of commercial production. |
231894403 | 2008-6-30 0:00: | AM | No Violations | |
343195994 | 2008-10-22 0:00 | PW | No Violations | |
397144601 | 2008-2-14 0:00: | PW | No Violations | |
885721932 | 2008-6-30 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0397144601 | US-OH-124226 | 2008-02-29 | Well insufficiently equipped to prevent escape of oil and gas | |
0397144601 | US-OH-124227 | 2008-02-29 | Failure to legibly identify well | |
0397144601 | US-OH-124228 | 2008-02-29 | Unlawful venting or flaring of gas | |
0397144601 | US-OH-124229 | 2008-02-29 | Well shall be plugged |
For data sources see[7]