X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-167-29137

Well Details

Well ID: 34-167-29137
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Barlow Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: SMITH-TACKETT
License Status: Producing
License Date: 1995-02-15
Spud Date: 1995-03-25
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 1995-03-30
Well Total Depth: 5586.00 ft
Configuration: Vertical
Latitude: 39.430000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1995-02-15 Issued Date 2/15/95 Expired Date 2/15/96 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05586 Proposed Drill Depth 05586
Original Spud 1995-03-25
Completed 1995-03-30
Reached Total Depth 1995-03-30
CO 1995-04-05 3434 GONZOIL INC GeoDate 2/15/95
Completion Report Received 1995-04-17
Construction Permit Expires 1996-02-15
Change of Owner 2008-08-14 Operator changed from 3434, GONZOIL INC to 8404, CONLEY ENERGY CO LLC
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5368 5445 0
5368 5445 0
2006-09-11 5372 5512 25
5372 5512 25
5368 5445 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 78500 Gal 70000 FRAC W/78,500 GAL SLICKWATER & 700

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 GONZOIL INC 3548.00 0.00 153
1996 GONZOIL INC 4513.00 0.00 365
1997 GONZOIL INC 1893.00 0.00 365
1998 GONZOIL INC 1693.00 0.00 365
1999 GONZOIL INC 1708.00 0.00 365
2000 GONZOIL INC 1006.00 0.00 365
2001 GONZOIL INC 1369.00 0.00 365
2002 GONZOIL INC 7.00 0.00 365
2003 GONZOIL INC 219.00 0.00 365
2004 GONZOIL INC 0.00 0.00 0
2005 GONZOIL INC 0.00 0.00 0
2006 GONZOIL INC 0.00 0.00 0
2007 GONZOIL INC 0.00 0.00 0
2008 GONZOIL INC 0.00 0.00 0
2012 CONLEY ENERGY CO LLC 0.00 0.00 363
2013 CONLEY ENERGY CO LLC 0.00 0.00 0
2014 CONLEY ENERGY CO LLC 0.00 0.00 0
2015 CONLEY ENERGY CO LLC 0.00 0.00 0
2016 CONLEY ENERGY CO LLC 0.00 0.00 0
2017 CONLEY ENERGY CO LLC 0.00 0.00 0
2018 CONLEY ENERGY CO LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 GONZOIL INC Brine 249 153
1996 GONZOIL INC Brine 0 365
1997 GONZOIL INC Brine 0 365
1998 GONZOIL INC Brine 0 365
1999 GONZOIL INC Brine 0 365
2000 GONZOIL INC Brine 0 365
2001 GONZOIL INC Brine 0 365
2002 GONZOIL INC Brine 0 365
2003 GONZOIL INC Brine 0 365
2004 GONZOIL INC Brine 0 0
2005 GONZOIL INC Brine 0 0
2006 GONZOIL INC Brine 0 0
2007 GONZOIL INC Brine 0 0
2008 GONZOIL INC Brine 0 0
2012 CONLEY ENERGY CO LLC Brine 0 363
2013 CONLEY ENERGY CO LLC Brine 0 0
2014 CONLEY ENERGY CO LLC Brine 0 0
2015 CONLEY ENERGY CO LLC Brine 0 0
2016 CONLEY ENERGY CO LLC Brine 0 0
2017 CONLEY ENERGY CO LLC Brine 0 0
2018 CONLEY ENERGY CO LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1539702302 2004-3-29 0:00: PL No Violations
-501035431 2004-9-29 0:00: PW No Violations
-880812067 2009-7-31 0:00: PW No Violations
0501035431 2004-09-29 Production Wells No Violations Re-inspect this day. It appears saltwater kill area below tank has dried up but probably because well not producing. Well head disconnected from sales line, chart in meter says 3?/03, tank has no IDs, good dike, but still saltwater slipped below it. Will call Doug and have serious talk about status of many of his wells - typical is saltwater leaking with kill spots, no IDs, wells not in production
0880812067 2009-07-31 Production Wells No Violations Inspection this day found casing well not in production, valves shut. Tanks are freshly painted but still need IDs, no meter in house, no chart, good dike. Location has had brine scald, now location has grown back, either tank was leaking or draining water but now looks good (but well isnt producing). Pumper has told me they plan to work on this well, will give them alittle time to do so.
1539702302 2004-03-29 Preliminary Restoration No Violations
1653792284 2015-04-30 Production Wells No Violations Upon inspection, it was observed that this well is not currently in production. The well consists of a 4.5 production casing with a 4-2 swedge and a ball valve in the closed position. The 2 steel flow line is currently disconnected from the well. The tank battery consists of a 100 bbl production tank, mechanical separator, drip, meter run, and containment dike. No chart is present in the meter run. Legible and correct ID information is present on the production tank. I will contact Conley Energy and inquire about plans to service this well.

For data sources see[9]

References