Well ID: 34-169-24963 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.91,"lon":-81.95,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Canaan Township | |
Operator Name: TRANSIT ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: ARMSTRONG JOHN & GLORIA | |
License Status: Producing | |
License Date: 1993-11-30 | |
Spud Date: 1993-12-16 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1993-12-22 | |
Well Total Depth: 5742.00 ft | |
Configuration: Vertical | |
Latitude: 40.910000 | |
Longitude: -81.950000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1993-11-30 | 1146 ENNEY OILFIELD COMPANY GeoDate 11/30/93 |
Oil and Gas | 1993-11-30 | Issued Date 11/30/93 Expired Date 11/30/94 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON/TPLU Proposed Depth 05742 Proposed Drill Depth 05742 |
Original Spud | 1993-12-16 | CHG FTG 1-8-94 |
Completed | 1993-12-22 | CHG FTG 1-8-94 |
Reached Total Depth | 1993-12-22 | CHG FTG 1-8-94 |
Completion Report Received | 1994-01-25 | CHG FTG 1-8-94 |
Construction Permit Expires | 1994-11-30 | CHG FTG 1-8-94 |
Change of Owner | 2016-07-22 | Operator changed from 1146, SCION ENERGY, INC. to 8775, SIGLER CONTRACT PUMPING INC |
Change of Owner | 2018-01-03 | Operator changed from 8775, SIGLER CONTRACT PUMPING INC to 2771, TRANSIT ENERGY INC |
Record Last Modified | 2018-01-03 | CHG FTG 1-8-94 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5536 | 0 | |
5536 | 0 | ||
2006-09-11 | 5539 | 0 | |
5539 | 0 | ||
5536 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 300 Gal | 0 | |||
ACID | 18 | 300 Gal | 0 | |||
0 | 0 | 0 | TREATED W/300 GAL 18% HCL | |||
0 | 0 | 0 | 86.2 BBLS./3620 GAL. DISPLACEMENT |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | SCION ENERGY INC | 56567.00 | 56.00 | 276 |
1995 | SCION ENERGY INC | 86445.00 | 125.00 | 365 |
1996 | SCION ENERGY INC | 77941.00 | 126.00 | 365 |
1997 | SCION ENERGY INC | 60081.00 | 101.00 | 365 |
1998 | SCION ENERGY INC | 38842.00 | 0.00 | 365 |
1999 | SCION ENERGY INC | 20087.00 | 0.00 | 360 |
2000 | SCION ENERGY INC | 0.00 | 0.00 | 365 |
2001 | SCION ENERGY INC | 3592.00 | 0.00 | 365 |
2002 | SCION ENERGY INC | 1844.00 | 0.00 | 365 |
2003 | SCION ENERGY INC | 1910.00 | 0.00 | 365 |
2004 | SCION ENERGY INC | 1693.00 | 0.00 | 365 |
2005 | SCION ENERGY INC | 1537.00 | 0.00 | 365 |
2006 | SCION ENERGY INC | 1255.00 | 0.00 | 365 |
2007 | SCION ENERGY INC | 882.00 | 0.00 | 365 |
2008 | SCION ENERGY INC | 730.00 | 0.00 | 365 |
2009 | SCION ENERGY INC | 135.00 | 0.00 | 94 |
2010 | SCION ENERGY INC | 76.00 | 0.00 | 123 |
2011 | SCION ENERGY INC | 0.00 | 0.00 | 0 |
2013 | SCION ENERGY INC | 0.00 | 0.00 | 0 |
2014 | SCION ENERGY INC | 0.00 | 0.00 | 0 |
2015 | SCION ENERGY INC | 0.00 | 0.00 | 0 |
2016 | SCION ENERGY INC | 0.00 | 0.00 | 0 |
2017 | SIGLER CONTRACT PUMPING INC | 151.00 | 0.00 | 365 |
2018 | TRANSIT ENERGY INC | 131.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | SCION ENERGY INC | Brine | 30 | 276 |
1995 | SCION ENERGY INC | Brine | 26 | 365 |
1996 | SCION ENERGY INC | Brine | 22 | 365 |
1997 | SCION ENERGY INC | Brine | 45 | 365 |
1998 | SCION ENERGY INC | Brine | 0 | 365 |
1999 | SCION ENERGY INC | Brine | 53 | 360 |
2000 | SCION ENERGY INC | Brine | 0 | 365 |
2001 | SCION ENERGY INC | Brine | 0 | 365 |
2002 | SCION ENERGY INC | Brine | 0 | 365 |
2003 | SCION ENERGY INC | Brine | 0 | 365 |
2004 | SCION ENERGY INC | Brine | 0 | 365 |
2005 | SCION ENERGY INC | Brine | 33 | 365 |
2006 | SCION ENERGY INC | Brine | 0 | 365 |
2007 | SCION ENERGY INC | Brine | 0 | 365 |
2008 | SCION ENERGY INC | Brine | 30 | 365 |
2009 | SCION ENERGY INC | Brine | 0 | 94 |
2010 | SCION ENERGY INC | Brine | 0 | 123 |
2011 | SCION ENERGY INC | Brine | 0 | 0 |
2013 | SCION ENERGY INC | Brine | 0 | 0 |
2014 | SCION ENERGY INC | Brine | 0 | 0 |
2015 | SCION ENERGY INC | Brine | 0 | 0 |
2016 | SCION ENERGY INC | Brine | 0 | 0 |
2017 | SIGLER CONTRACT PUMPING INC | Brine | 0 | 365 |
2018 | TRANSIT ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1422585531 | 2017-2-2 0:00:0 | PL | No Violations | |
-277631989 | 2016-12-8 0:00: | PL | No Violations | |
-285565528 | 2016-5-19 0:00: | PL | No Violations | |
0277631989 | 2016-12-08 | Preliminary Restoration | No Violations | Inspected production well on 12/08/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0285565528 | 2016-05-19 | Preliminary Restoration | No Violations | Pits have been closed and all drilling equipment has been removed. Preliminary restoration passes. |
0799851732 | 2017-02-02 | Production Wells | No Violations | Inspected production well on 02/02/2017. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-horizontal separator is located nearby. Well identification is posted at the tank battery, but it needs updated to reflect the current operator. Tim Sigler, with Sigler Contract Pumping, was notified of this issue and will address it promptly. The well is a rabbit well. No other problems were noted at the time of the inspection. |
0958966184 | 2018-02-22 | Production Wells | No Violations | Inspected production well on 02/22/2018. The tank battery consists of 1-100 bbl steel tank, located within an earthen dike; 1-horizontal separator with a drip and meter box are located within a separate earthen dike. Well identification is clearly displayed at the tank battery. The well is a rabbit well. No problems were noted at the time of the inspection. |
1065921443 | 2016-05-19 | Production Wells | No Violations | Inspected production well on 05/19/2016. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator, each located within a separate earthen dike. Well identification is posted at the tank battery. The well is a rabbit well. No problems were noted at the time of the inspection. |
1397316722 | 2016-12-08 | Production Wells | No Violations | Inspected production well on 12/08/2016. The tank battery consists of 1-100 bbl steel tank and 1-horizontal separator, each located within separate earthen dikes. Well identification is clearly displayed at the tank battery. The well is a rabbit well. No problems were noted at the time of the inspection. |
1422585531 | 2017-02-02 | Preliminary Restoration | No Violations | Inspected production well on 02/02/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
733584619 | 2020-4-23 0:00: | PW | No Violations | |
799851732 | 2017-2-2 0:00:0 | PW | No Violations | |
958966184 | 2018-2-22 0:00: | PW | No Violations |