34-173-20563

Well Details

Well ID: 34-173-20563
Loading map...
Country: United States
State: Ohio
County: Wood
Municipality: Portage Township
Operator Name: PORTAGE TWP TRUSTEES
Well Pad ID:
Farm/Lease Name: PORTAGE TWP TRUSTEES
License Status: Final Restoration
License Date: 2003-01-21
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.260000
Longitude: -83.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-01-21 Proposed Formations:TRENTON, Issued Date:1/21/2003, Expired Date:1/21/2004 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged by Orphan Well Program 2003-08-12 Plugged by Orphan Well Program
Plugged/Abandoned 2003-08-12 RBDMS Rec
Construction Permit Expires 2004-01-21 RBDMS Rec
Record Last Modified 2013-03-14 RBDMS Rec

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-63546823 2003-10-22 0:00 FR No Violations
0063546823 2003-10-22 Final Restoration No Violations Reviewed site for final restoration. Areas disturbed by plugging operation have vegetation growing. All equipment removed. Final restoration acceptable.
1060889124 2003-08-12 Orphan No Violations DETAILED COMMENTS FOR PLUG REPORT. Operator could not reach total depth of 1300 feet as noted in permit. Rig was on site and drilling over a period of 4-5 months. Met on site with Bob Harpster on 7/30/03. Drilling was gaining only 2-3 feet per day. There was no casing in the hole other than the 40 feet of plastic casing installed by the operator. A total depth of 270 feet was obtained. Water wells in the area are less than 100 feet deep as verified by the operator and Township Trustee. Consultation with Dave Hodges, Jeff Fry and Sam Faust agreed to allow the well to be plugged at 270 feet. Hole was 8 inches in diameter and 3.5 cu. yd. cement were calculated to fill the hole. Cement began returning to the formation at approximately 100 feet depth. A total of 5 cu.yd. were needed to plug the hole. Cement held at approximately 3 feet below ground level after 30 minutes. Pipe was cut off at 7 feet below ground level since this is a cemetary. Bob Harpster said an ID plate will be attached to the top of the well.
1064864459 2003-09-15 Orphan No Violations Reviewed reclamation of site with Jeff Fry. A tank remains on site that must be removed. Some additional resoiling and seeding needs to be done.
1065460385 2003-10-02 Orphan No Violations Reviewed site at request of operator Bob Harpster. Tank has been removed and remaining areas have been seeded. Vegetation must be growing before final restoration can be approved. This is required before payment is made for project.

For data sources see[3]