{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.3,"lon":-83.63,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wood | |
Municipality: Portage Township | |
Operator Name: OHIO ENERGY OPERATORS LLC | |
Well Pad ID: | |
Farm/Lease Name: DOVE (SWIW # 4) | |
License Status: Active Injection | |
License Date: 2011-06-07 | |
Spud Date: 2011-06-30 | |
Spud Drilling Contractor: ADVANCED ENERGY SERVICES LLC | |
Final Drill Date: 2011-07-09 | |
Well Total Depth: 3200.00 ft | |
Configuration: Vertical | |
Latitude: 41.300000 | |
Longitude: -83.630000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-06-08 | Proposed Formations:MT. SIMON, Issued Date:10/1/2013, Expired Date:10/1/2015 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:ST, Proposed Well Class:STRT |
Reached Total Depth | 2011-07-09 | Deepest FMTN updated by DGS-PG-2 |
Annulus Pressure Monitoring Approved | 2011-08-24 | Deepest FMTN updated by DGS-PG-2 |
Last Compliance Report | 2011-09-19 | Deepest FMTN updated by DGS-PG-2 |
Construction Permit Expires | 2013-06-07 | Deepest FMTN updated by DGS-PG-2 |
Correction to Well | 2013-10-14 | CORRECTION TO PERMIT NUMBER. |
Change of Owner | 2015-01-27 | Operator changed from 8750, WESTERN NATURAL RES OP LLC to 9423, OHIO ENERGY OPERATORS LLC |
Completion Report Received | 2016-03-22 | Deepest FMTN updated by DGS-PG-2 |
Record Last Modified | 2019-04-03 | Deepest FMTN updated by DGS-PG-2 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-10-02 | 2060 | 2427 | 0 |
2060 | 2427 | 0 | |
2060 | 2427 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1025712031 | 2014-1-15 0:00: | SW | No Violations | |
-1061260246 | 2016-10-27 0:00 | SW | No Violations | |
-1072192182 | 2013-11-6 0:00: | SW | No Violations | |
-1146769920 | 2019-2-21 0:00: | SW | No Violations | |
-1201571996 | 2017-5-19 0:00: | SW | No Violations | |
-1224494777 | 2019-5-9 0:00:0 | SW | No Violations | |
-1252448198 | 2014-9-10 0:00: | SW | No Violations | |
-1256831728 | 2018-7-27 0:00: | SW | No Violations | |
-1353261509 | 2017-8-17 0:00: | SW | No Violations | |
-1367541678 | 2011-8-8 0:00:0 | PW | No Violations | |
-1480718630 | 2012-6-12 0:00: | SW | No Violations | |
-1503416414 | 2014-7-2 0:00:0 | SW | No Violations | |
-156394722 | 2015-10-15 0:00 | SW | No Violations | |
-1594180517 | 2017-7-20 0:00: | SW | No Violations | |
-1654306375 | 2017-8-29 0:00: | SW | No Violations | |
-166413692 | 2016-8-11 0:00: | SW | No Violations | |
-1747564648 | 2011-9-8 0:00:0 | SW | No Violations | |
-1761808815 | 2018-6-29 0:00: | SW | No Violations | |
-1805133815 | 2019-5-30 0:00: | SW | No Violations | |
-1808281390 | 2018-6-7 0:00:0 | SW | No Violations | |
-1841648337 | 2020-5-6 0:00:0 | SW | No Violations | |
-1865741284 | 2017-6-7 0:00:0 | SW | No Violations | |
-1902773304 | 2016-3-16 0:00: | SW | No Violations | |
-1959775496 | 2015-3-26 0:00: | SW | No Violations | |
-1997396416 | 2019-1-8 0:00:0 | SW | No Violations | |
-2022007916 | 2018-4-11 0:00: | SW | No Violations | |
-205800160 | 2015-4-14 0:00: | SW | No Violations | |
-2078216268 | 2019-4-15 0:00: | SW | No Violations | |
-2103262566 | 2012-11-27 0:00 | SW | No Violations | |
-231818055 | 2014-10-8 0:00: | SW | No Violations | |
-286308721 | 2011-9-12 0:00: | SW | No Violations | |
-287291058 | 2019-10-22 0:00 | SW | No Violations | |
-352915396 | 2019-6-19 0:00: | SW | No Violations | |
-45673882 | 2012-1-3 0:00:0 | SW | No Violations | |
-472586446 | 2013-7-17 0:00: | SW | No Violations | |
-478266481 | 2016-5-19 0:00: | SW | No Violations | |
-566992910 | 2011-10-4 0:00: | SW | No Violations | |
-654893057 | 2015-4-28 0:00: | SW | No Violations | |
-687911172 | 2011-9-26 0:00: | SW | No Violations | |
-705659722 | 2016-4-20 0:00: | SC | No Violations | |
-718282156 | 2017-9-19 0:00: | SW | No Violations | |
-763212666 | 2016-4-7 0:00:0 | SW | No Violations | |
-94787852 | 2018-5-4 0:00:0 | SW | No Violations | |
-981730029 | 2015-1-21 0:00: | SW | No Violations | |
0045673882 | 2012-01-03 | Salt Water Injection Well | No Violations | On site to check status of Preliminary Restoration. Pit was closed but area still needs graded. Wet conditions have slowed restoration of site. |
0094787852 | 2018-05-04 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Reports received 7/19/2018. |
0107792080 | 2018-09-27 | Salt Water Injection Well | No Violations | Inspect surface facility and pump house. The flow meter indicated a rate of 323 barrels per day. |
0148182475 | 2017-06-29 | Salt Water Injection Well | No Violations | Inspect surface facility. Contact pumper and discuss operations. |
0156394722 | 2015-10-15 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
0166413692 | 2016-08-11 | Salt Water Injection Well | No Violations | Inspect well and storage tank area. The well is shut in. The electric motor has been removed for repairs. The triplex pump intake nipple has been repaired and replaced with a stainless steel nipple. The flow meter has been repaired. A three inch transfer line from the separator has been replaced with schedule 80 PVC pipe. A two inch transfer line near the base of the separator tower has a slow leak. The concrete pad for the tower separator is deteriorating and the integrity is in question. The horizontal separator has broken sight tube fittings and the two inch change over from PVC to steel is leaking. Free standing oil is present in the dike. The operator is advised to utilize a steam pressure washer to clean the liner and remove the oil. The operator is advised to replace all flow lines in the containment area and remove any equipment that is not required. The operator may consider placing the tri-plex pump onto blocks within the dike area to prevent future flooding of the pump and motor. The operator shall notify the DOGRM prior to initiating production of producing wells and the injection well. |
0188899962 | 2016-08-22 | Surface Facility Construction | No Violations | Inspect cleanup and repair operations conducted by operator. The debris that has been accumulated within the dike area has been removed. The tri-plex pump has been jacked up and placed on cribbing. The extra flow lines have been removed. The operator has been working on cleaning the tanks and dike area with a power washer. This operation has not been completed as of this inspection. Replacement supplies including heavy wall PVC line, support blocks and 2 by 12 are stockpiled at the location. The operator intends to reinforce the concrete pad for the heater treater tower. |
0205800160 | 2015-04-14 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
0231818055 | 2014-10-08 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. |
0246454135 | 2018-03-12 | Salt Water Injection Well | No Violations | Inspect surface facility and well. |
0284475526 | 2016-05-17 | Surface Facility Construction | No Violations | The operator installed continuous WL Plastics Corp. 1 1/4 pipe, rated at 336 lbs, thickness is 0.237 PVC through 3 inch PVC conduit. Tested line for 25 minutes, stabilized after 10 minutes. Riser pipe at pump and all fittings are stainless steel. Originally attempted utilize 3 inch Harvel PVC but multiple glue joints failed pressure testing. Therefore a smaller diameter continuous pipe was threaded through the 3 inch PVC pipe. This conduit is not secondary containment. The line test passed at 290 psi. |
0286308721 | 2011-09-12 | Salt Water Injection Well | No Violations | Tubing and packer re-run in hole after replacement of shear pin on packer. Circulate fluid and inhibitor. Test annulus at 700 psi for 15 minutes. No loss in pressure. |
0301022086 | 2016-06-07 | Surface Facility Construction | No Violations | Inspect well, storage area, and retest line at request of operator. The 1.25 inch flow line installed May of 2105 was pressure tested at 358 psi; 349 psi at 5 minutes; 345 psi at 10 minutes; 342 at 15 minutes; and 340 psi at 20 minutes. The initial loss is less than 5 percent. Line passes test and was put into production. |
0386751951 | 2017-05-17 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The threads on the nipple at the elbow is rusted at the well head. Contacted operator to report condition of nipple. |
0472586446 | 2013-07-17 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. The concrete base for the heater treater is deteriorating. |
0478266481 | 2016-05-19 | Salt Water Injection Well | No Violations | Inspect well and location. The pump was in operation, check pressure at pump at 280 psi. The nipple at the well head had a slow leak and was repaired by well tender subsequent to visit. Annulus pressure was 240 psi. Re-inspected well later in day. Leaking nipple was replaced. Well head pressure and annulus were tested. The pump was not in operation. The tubing was on vacuum and the annulus was 235 psi. |
0521329531 | 2018-12-03 | Salt Water Injection Well | No Violations | Inspect surface facility. Pump is not in operation. |
0566992910 | 2011-10-04 | Salt Water Injection Well | No Violations | Inspect well. Well shut in and not in production. |
0593035692 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
0654893057 | 2015-04-28 | Salt Water Injection Well | No Violations | Inspect well and tanks. Triplex transfer pump in operation during inspection. Pressure at pump indicated 200 psi. |
0687911172 | 2011-09-26 | Salt Water Injection Well | No Violations | Conduct injection line pressure test. Fifteen minute test passes. |
0705659722 | 2016-04-20 | Surface Facility Construction | No Violations | The operator installed Harvel PVC 1120 at 3 inch Schedule 80 ASTM D 1285 pipe rated to 370 psi at 73 degrees Fahrenheit. Twenty one 20 foot sections were installed and connected with connections glued with cement. The line is about 420 feet long. The operator buried about half the line. The flow line was loaded with water and was attempted to pressure test line. The test pressure was not achieved. The operator was tasked with locating the leak. |
0718282156 | 2017-09-19 | Salt Water Injection Well | No Violations | Inspect surface facility. Heavy rain during inspection. |
0763212666 | 2016-04-07 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
0763822086 | 2015-12-09 | Salt Water Injection Well | No Violations | Inspect well and location. Well is in compliance. The flow meter indicated 2590 bbl at 260 bbl per day. |
0784746252 | 2013-04-03 | Salt Water Injection Well | No Violations | At the time of the inspection the well was shut in. |
0827279308 | 2014-02-21 | Salt Water Injection Well | No Violations | At the time of the inspection the well was capable of injection but not currently in operation. The operator, Western Natural Res Op LLC, has gone bankrupt and the well was sold to the landowner in a Sheriffs Auction. The landowner, Mr. Carpenter, is looking to have another operator take over the wells and the lease. The well is not to be operated until a properly registered/insured operator obtains the well. A new storage tank was put on site and according to the landowner it is used as a Temporary Oil Storage Facility for a separate operator and is not affiliated with the current production/injection wells. Inspector Tom Benko is working with this operator and landowner to determine if the facility is properly permitted. |
0920155141 | 2016-08-31 | Surface Facility Construction | No Violations | The operator has begun cleanup of surface facility and has removed un-necessary piping. The pipe runs have been disconnected from the brine storage tanks. The west 300 bbl steel storage tank shows sighs of a leak about 12 feet from the base of the tank. The operator has previously reported that he is going to purchase fiberglass storage tanks to replace the steel tanks. |
0948980166 | 2011-07-09 | Drill / Deepen / Reopen | No Violations | On site at 11pm for cementing of 2087 of 7. Formation Cementing ran 1200lbs of gel ahead of cement then ran 160 sacks of lite class A (4% gel) and 130 sacks class A (2% gel). Circulation of fluid throughout job but no cement returns, just gel. |
0965872703 | 2012-02-09 | Salt Water Injection Well | No Violations | Inspect Well. Pumping rate 555 bbl/day |
0967120829 | 2016-05-03 | Surface Facility Construction | No Violations | Operator conducting line test. The line test of April, 26, 2016 failed due to a leaking fitting at the 45 in the pipe run. Fittings were replaced and line loaded with water for testing. Conduct pressure test of the line with target pressure of 250 psi. The fittings at the well head and tank battery had slow leaks and were tightened after the initial test. The line was pressured up to 240 psi. There was a loss in pressure about 10 psi per minute from the line. Operator was advised to locate a line leak. |
0981730029 | 2015-01-21 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. |
1025712031 | 2014-01-15 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. A 210 bbl tank has been set in an earthen dike East of the existing tank battery. The Pickup number is 42889. |
1061260246 | 2016-10-27 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The salt water tanks have been removed from the dike area and will be cleaned and scrapped. The new 210 fiberglass storage tanks have been installed and plumbed in. The operator will begin operations when an overflow float valve is received and installed. |
1072192182 | 2013-11-06 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Shut in. |
107792080 | 2018-9-27 0:00: | SW | No Violations | |
1189895297 | 2017-01-17 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The operator reported the meter was recently replaced. |
1201571996 | 2017-05-19 | Salt Water Injection Well | No Violations | Contacted by operator to report the rusted nipple noted in the May 17, 2017 inspection report was repaired and replaced. |
1239981045 | 2016-05-10 | Surface Facility Construction | No Violations | Pressure up recently installed three inch flow line to test for leaks. Previous leaks were reportedly repaired. Upon arrival at location the operator pressured up the line for testing and shortly thereafter a fitting failed. Pressure testing of the line did not occur due to the failure. The operator determined while the installation of the pipe line occurred the banks of the trench collapsed onto the pipe before the glue fittings were completely cured. This has caused the fittings to repeatedly fail at various locations. The attempt to use this pipe for water discharge will not occur. The intention will be to insert a smaller diameter pipe through the 3 inch pipe as a conduit to the well. |
1252448198 | 2014-09-10 | Salt Water Injection Well | No Violations | Inspect well and location. No activity has occurred at the location. Contacted Richard Carpenter the landowner who forfeited the lease in Wood County Court with Western Natural Resources for failure of payment to landowner and equipment suppliers and purchased wells and equipment at Sheriffs auction. Mr. Carpenter stated he is in negotiations with a potential operator to produce the production wells and the injection well. A disposition should be determined by the end of 2014. The termination of the lease is filed in the Wood County Recorders office Official Record 9/7/2013 Vol. 3155 page 524 and 9/19/2012 Vol. 3158 page 474. |
1256831728 | 2018-07-27 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The pump was off during the inspection. |
1283201474 | 2015-07-15 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Pump in operation during inspection with 335 psi at pump outlet. Rate of 170 bbl/day. |
1309873109 | 2011-07-05 | Drill / Deepen / Reopen | No Violations | Currently at 992. Conductor set on July 1st and Surface casing set on July 4th. B.O.P. Tested to 500 psi for 30min. One large lined pit, shale shaker, pumps, rig , doghouse, two tan trailers and other smaller equipment. |
1309977433 | 2011-07-06 | Drill / Deepen / Reopen | No Violations | Currently at 2192 and still drilling on fluid. Started collecting samples at 1000 |
1310392280 | 2011-07-07 | Drill / Deepen / Reopen | No Violations | On site @ 2:30 am. T.D. reached about 1:30 am ( 2427). John Hudson of Appalachian well service on site at 3 am for a cement bond log on surface casing as ordered by Tom Tomastik. I received copy and an electronic copy sent to Tom the next morning. |
1311613505 | 2011-07-15 | Drill / Deepen / Reopen | No Violations | On site for a cement bond log on 7 intermediate string. Appalachian Well Service did the log as ordered by Tom Tomastik. Log shows good cement to 125 from surface in the surface casing. |
1313066887 | 2011-08-08 | Salt Water Injection Well | No Violations | Inspect well and vicinity for conversion of well to salt water injection well (SWIW) at request of T. Tomastik. The well has been drilled. Cement for intermediate string is currently at about 140 feet below grade. Annulus and cellar are flooded with surfa |
1315926212 | 2011-08-31 | Drill / Deepen / Reopen | No Violations | On site to top off Annulus space between 7 and 9 5/8 Surface Casing. Bond log put Toc from previous cement job at about 140. 1 PVC in ten sections was glued together and lowered in to 100 before it stopped to use as vent for water. Formation cementing pumped 25 sacks with good circulation to surface. |
1353261509 | 2017-08-17 | Salt Water Injection Well | No Violations | Inspect well. Operator attempted to treat well with 55 gallons of acid. The treatment caused the iron sulfide and rust scale to plug off tubing at about 600 feet below grade. The operator had a service rig on the well and was attempting to clean out the 2 7/8 inch upset tubing with a 2.5 inch cable tool drill bit and bailer. The scale buildup started at 300 feet below grade. The operator will be required to conduct a mechanical integrity test on the annulus when this operation is complete. |
1367541678 | 2011-08-08 | Production Wells | No Violations | Inspect well. no dikes at tanks. This is going to be a production well converted to a UIC well. |
1394198490 | 2014-02-27 | Salt Water Injection Well | No Violations | Received information that tanker trucks were arriving and leaving location. Contacted the Landowner who reported that Jack Racer of R&S Drilling had established a lease to set an oil tank to load oil for pickup by Ergon for first purchase. Contacted Jack Racer to confirm activities. Inspected injection well and tanks. No activity has occurred at the production or injection well. |
1439814250 | 2015-07-27 | Salt Water Injection Well | No Violations | Inspect well. The threads on the nipple at the flow meter are beginning to deteriorate. Collect Brine sample TSB082 for chemical analysis. |
1459344139 | 2016-03-29 | Salt Water Injection Well | Violations Noted | Inspect well, tank battery, and location. Multiple line failures have occurred and were repaired with galvanized steel pipe. Contacted Craig Schlicht regarding the notification requirement of flow line repairs. The operator stated due to the extended period of non-use the flow line is becoming compromised. The operator reported he intends to replace the flow line from the tanks to the well with a continuous piece of schedule 80 plastic pipe The grass at low lying areas near the tank battery are visibly burned. The operator was advised the accumulation of rain water within the dike area needs to be transferred into the salt water storage tanks for disposal in the salt water injection well. |
1461941528 | 2016-04-18 | Salt Water Injection Well | No Violations | Inspected site of the above the well. Operator is currently replacing flow line to well because of leakage. Operator is using a three inch pvc schedule 80 pipe that is manufactured by Harvel Industrial. Operator backfilled the entire length of pipe so coupling were not observed. Pipe dope used is approved for use with brine solutions. |
1471005039 | 2016-08-02 | Salt Water Injection Well | Violations Noted | Inspect well for integrity and pressure. The meter at the well head has failed and was dismantled for battery replacement. The tri-plex pump discharge nipple failed and the discharge line sheared off from the pump. This failure caused the contents of the two brine storage tanks to release into the dike containment area. The fluid was contained in the dike containment area. The operator discovered the on Friday July 30, 2016. The operator pumped the water into the storage tanks and emptied the dike containment area. Notification was not made to DOGRM. |
1471814188 | 2018-01-17 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
1480718630 | 2012-06-12 | Salt Water Injection Well | No Violations | Inspect Well. Well is shut in. At date of inspection the landowner is not allowing anybody on site due to legal issues with operator. |
148182475 | 2017-6-29 0:00: | SW | No Violations | |
1501976282 | 2012-09-19 | Salt Water Injection Well | No Violations | At the time of my inspection there was a gate across the access lane to the well that was put up by the landowner. I called the landowner and left a message about gaining access to the well. |
1503416414 | 2014-07-02 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. Well is shut in. |
1504263341 | 2017-08-31 | Salt Water Injection Well | No Violations | Inspect well for pressure and integrity. Service activity has been completed and well has been put back into production. The pump is in operation during inspection; the pressure at the pump was measured at 235 psi, flow meter indicates 1289 barrels per day; the pressure at the well head was measured at 150 psi. Measure the specific gravity of the water at 1.06 units equates to water weight of 8.834 pounds per gallon. |
1521633147 | 2018-03-19 | Salt Water Injection Well | No Violations | Inspect well for integrity. |
1537534835 | 2016-08-24 | Surface Facility Construction | No Violations | Contacted by phone; Craig Schlicht reported that during the cleanup operations and power washing the brine storage tanks that a pin hole leak was discovered. The operator has decided to put the remaining reconstruction activities on hold until fiberglass storage tanks can be purchased and delivered. |
1539960345 | 2018-10-04 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The flow rate is at 290 barrels per day. |
1540010050 | 2017-10-24 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
1564596910 | 2019-7-8 0:00:0 | SW | No Violations | |
1573134766 | 2019-11-4 0:00: | SW | No Violations | |
1577191047 | 2019-11-20 0:00 | SW | No Violations | |
1582300565 | 2020-2-14 0:00: | WR | No Violations | |
1593457123 | 2020-6-29 0:00: | SW | No Violations | |
1594180517 | 2017-07-20 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The pump was not in operation during inspection. |
1654306375 | 2017-08-29 | Salt Water Injection Well | No Violations | Service rig is on well to clean out blockage of iron sulfide and rust scale in the 2 7/8 inch tubing. The operator used a 2.5 inch cable tool drill bit and 2 inch bailer to drill out the obstruction. Upon arrival the operator was tripping out of the hole after reaching the bottom of the tubing and the hole. The operator measured the fluid level with a digital echo meter. The fluid level in the annulus was measured at 121 feet below grade and the tubing was measured at 464 feet below grade. The annulus was pressure tested for integrity because of the clean out activity. A 230 cubic foot bottle of nitrogen was used to pressure the annulus to 85 psi and monitored for more than 15 minutes with zero pressure loss. A second 230 cubic foot bottle of nitrogen was used to increase the pressure to 160 psi and monitored for 15 minutes with zero pressure loss. The operator was given authorization to resume injection operations. |
1663377491 | 2012-09-20 | Salt Water Injection Well | No Violations | At the time of my inspection the injection line was shut in between the meter and the pump. The well has not been in operation since the last inspection on 6/12/2012. The injection tubing was on a vacuum. |
1665719112 | 2011-06-30 | Drill / Deepen / Reopen | No Violations | Rig has moved on site. Pits are cut. Operator waiting on pipe, drilling has not started. |
1699975128 | 2016-01-28 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. The Flow meter indicated 252 bbl per day. |
1718301009 | 2019-3-15 0:00: | SW | No Violations | |
1747564648 | 2011-09-08 | Salt Water Injection Well | No Violations | Tubing and packer run in hole. Attempt to set packer and test well. Driller pulled too hard on packer and sheared pins when attempting to set packer. Tubing and packer will need to be tripped out and rerun. |
1761808815 | 2018-06-29 | Salt Water Injection Well | No Violations | Inspect storage tanks. The flow meter indicates a rate of 252 barrels per day. |
1808281390 | 2018-06-07 | Salt Water Injection Well | No Violations | Inspect well for pressure and integrity. The operator has moved the flow meter from the well head location to the tank / pump location. The flow meter indicated a rate of 254 barrels per day. |
1855162621 | 2016-08-18 | Surface Facility Construction | No Violations | The production and injection systems have been shut down. Lynn Blair and Craig Schlicht are on site to begin cleanup and construction repairs on the storage tanks and lines. |
1865741284 | 2017-06-07 | Salt Water Injection Well | No Violations | Inspect well and storage area. |
1871547707 | 2019-8-12 0:00: | SW | No Violations | |
1881601875 | 2016-06-06 | Salt Water Injection Well | No Violations | Inspect well and storage facility. The triplex pump was in operation during inspection. The line pressure was 300 psi at the pump. |
188899962 | 2016-8-22 0:00: | SC | No Violations | |
1894912254 | 2008-02-13 | Orphan | No Violations | Well located in farm field has rods and tubing in well and will be submitted to the I&O program. |
1902773304 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED |
1930828907 | 2014-04-14 | Salt Water Injection Well | No Violations | Inspect well for annulus and injection pressure. Well is shut in. |
1931537825 | 2018-11-26 | Salt Water Injection Well | No Violations | Inspect surface facility and pump. The pump is not in operation. The pump meter is 6597.2 barrels at rate of 187 barrels per day. |
1959775496 | 2015-03-26 | Salt Water Injection Well | No Violations | New operator has initiated activities to restart operations. Lynn Blair 270-543-0131 is a contract / consultant hired by Ohio Energy Operators LLC to restart production and injection wells. Craig Schlicht 719-331-3045 is the direct contact for Ohio Energy Operators LLC. Operator reported a nipple for a valve on the brine water tank was removed and replaced due to a slow leak. |
2022007916 | 2018-04-11 | Salt Water Injection Well | No Violations | Inspect well for integrity and pressure. |
2047264810 | 2016-04-26 | Surface Facility Construction | No Violations | The operator installed Harvel PVC 1120 at 3 inch Schedule 80 ASTM D 1285 pipe rated to 370 psi at 73 degrees Fahrenheit. Twenty one 20 foot sections were installed and connected with connections glued with cement. The line is about 420 feet long. The operator buried about half the line. The first line test was on April 20th. The test failed due to a line leak near the well head at the riser to the surface. The leak was repaired and the steel riser pipe was replaced with a PVC pipe. The flow line was loaded with water and the line was pressure tested. The test pressure to attain was 300 psi. While pressure the line at about 280 psi a fitting failed and the pressure rapidly dropped to about 20 psi. During this testing process 20 psi was not exceeded and the 600 psi rated shut off valve catastrophic failed. The valve was replaced with a second new valve. The test pressure was not achieved. The operator was tasked with locating the leak. |
2061013014 | 2020-6-1 0:00:0 | SW | No Violations | |
2062124354 | 2020-4-2 0:00:0 | SW | No Violations | |
2092341910 | 2013-09-04 | Salt Water Injection Well | No Violations | Contacted property owner who purchased assets of Western Natural Resources Operating LLC at Sheriff auction. Richard Carpenter intends to find an operator to establish new lease. 15711 Carter Road, Bowling Green, Ohio 419-354-2242. |
2103262566 | 2012-11-27 | Salt Water Injection Well | No Violations | At the time of my inspection the well was shut in at the line from the tank battery and there was 0 on the Flow Meter. There was no identification posted at the well or at the tank battery. |
2119254168 | 2012-09-20 | Preliminary Restoration | No Violations | At the time of my inspection the pits were closed and the area graded back to farmland. Preliminary Restoration Passed. |
212380484 | 2020-5-6 0:00:0 | SW | No Violations | |
246454135 | 2018-3-12 0:00: | SW | No Violations | |
264021864 | 2020-3-12 0:00: | SW | No Violations | |
284475526 | 2016-5-17 0:00: | SC | No Violations | |
301022086 | 2016-6-7 0:00:0 | SC | No Violations | |
386751951 | 2017-5-17 0:00: | SW | No Violations | |
478066059 | 2020-4-24 0:00: | SW | No Violations | |
521329531 | 2018-12-3 0:00: | SW | No Violations | |
593035692 | 2019-4-29 0:00: | SW | No Violations | |
763822086 | 2015-12-9 0:00: | SW | No Violations | |
784746252 | 2013-4-3 0:00:0 | SW | No Violations | |
827279308 | 2014-2-21 0:00: | SW | No Violations | |
920155141 | 2016-8-31 0:00: | SC | No Violations | |
948980166 | 2011-7-9 0:00:0 | DD | No Violations | |
965872703 | 2012-2-9 0:00:0 | SW | No Violations | |
967120829 | 2016-5-3 0:00:0 | SC | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0094787852 | US-OH-130845 | 2018-08-03 | Failure to file salt water injection annual report | |
0593035692 | US-OH-126676 | 2019-05-09 | Failure to file salt water injection annual report | |
1459344139 | US-OH-113305 | 2016-05-25 | Contamination at surface facility (permit after 6-1-82) | |
1471005039 | US-OH-113536 | 2016-11-23 | Tanks not liquid tight/Improper burial | |
1902773304 | US-OH-119122 | 2016-04-04 | Failure to file salt water injection annual report |