34-173-61207

Well Details

Well ID: 34-173-61207
Loading map...
Country: United States
State: Ohio
County: Wood
Municipality: Bloom Township
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: KELLEY
License Status: Plugged and Abandoned
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.200000
Longitude: -83.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2008-06-10 WELL INSPECTED BY KEN PIISPANEN ON 2/13/2008 TO SUBMIT TO THE I&O PROGRAM.
Changed to Orphan Well Ready 2008-09-01 Changed Well To Orphan Ready
Record Last Modified 2019-03-25 WELL INSPECTED BY KEN PIISPANEN ON 2/13/2008 TO SUBMIT TO THE I&O PROGRAM.

Case # 2008 09 031 UPDATED LOCATION PER DOGRM SURVEYOR 11/27/18-ALE

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0692916645 2019-01-17 Plug / Plug Back No Violations A second bottom plug was installed to this well because of the lack of fill up from the first bottom plug installed to this well on 1/15/2019. Installed 50 sacks of Class A Cement through 1.5 inch tubing. No circulation was observed during the plugging process.
1552310964 2019-01-15 Plug / Plug Back No Violations Installed 40 sacks of Class A Cement through 1.5 inch tubing for the purpose of installing a bottom plug on this orphan well. No circulation was observed during the plugging process.
1719951254 2008-01-23 Orphan No Violations Well located in farm field has open 6 inch casing filled with dirt and odor of gas will be submitted to the I&O program.
1889949698 2019-01-28 Plug / Plug Back No Violations A adequate bottom plug was measured at a depth of 454 feet and it was determined to place the surface casing plug on top of the bottom plug without any spacing. Eighty sacks of Class A Cement was installed through 1.5 inch tubing and cement was briefly witnessed at the surface. After the tubing was removed this plug was measured at a depth of 30 feet .
692916645 2019-1-17 0:00: PB No Violations