37-003-22226

Well Details

Well ID: 37-003-22226
Loading map...
Country: United States
State: Pennsylvania
County: Allegheny
Municipality: Plum Borough
Operator Name: PENNECO OIL CO INC
Well Pad ID:
Farm/Lease Name: GOSPEL CHURCH UNIT 10H
License Status:
Spud Date:
Permit Date: 2012-06-13
Well Type: OIL
Unconventional Well: N
Configuration: Deviated Well
Conservation: No
Latitude: 40.483867
Longitude: -79.726083

For data sources see[1][2][3]

Well History

Date Event
2012-06-13 New Permit Application
2012-08-06 Performed Spud Operation
2012-09-28 Drilling Completion
2013-04-02 Perforation
2013-05-29 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 PENNECO OIL CO INC 0.00 0 0.00 0 0.00 0
2013 PENNECO OIL CO INC 8,542.00 214 22803.60 214 0.00 0
2014 PENNECO OIL CO INC 15,021.00 365 11465.82 365 0.00 0
2015 PENNECO OIL CO INC 10,443.10 365 1989.35 304 0.00 0
2016 PENNECO OIL CO INC 9,864.40 366 1060.36 184 0.00 0
2017 PENNECO OIL CO INC 8,477.00 365 1,422.16 365 0.00 0
2018 PENNECO OIL CO INC 9,917.75 365 1,249.50 246 0.00 0
2019 PENNECO OIL CO INC 8,131.99 365 1,117.34 214 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 PENNECO OIL CO INC Produced Fluid 230.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 PENNECO OIL CO INC Drilling Fluid Waste 401.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 PENNECO OIL CO INC Drilling Fluid Waste 2,263.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2013 PENNECO OIL CO INC Drilling Fluid Waste 721.43 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 PENNECO OIL CO INC Produced Fluid 1,982.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2013 PENNECO OIL CO INC Drilling Fluid Waste 721.43 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2013 PENNECO OIL CO INC Fracing Fluid Waste 740.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2013 PENNECO OIL CO INC Drilling Fluid Waste 613 Bbl CENT WASTE TRT FAC NPDES PA0091472
2013 PENNECO OIL CO INC Fracing Fluid Waste 740 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 PENNECO OIL CO INC Produced Fluid 1,982.00 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 PENNECO OIL CO INC Drilling Fluid Waste 613.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0091472
2014 PENNECO OIL CO INC Fracing Fluid Waste 500.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2014 PENNECO OIL CO INC Fracing Fluid Waste 500 Bbl CENT WASTE TRT FAC NPDES PA0095443
2014 PENNECO OIL CO INC Produced Fluid 807 Bbl CENT WASTE TRT FAC NPDES PA0095443
2014 PENNECO OIL CO INC Produced Fluid 807.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2019 PENNECO OIL CO INC Produced Fluid 290.67 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2019 PENNECO OIL CO INC Produced Fluid 160.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2074406 Primary Facility 2012-05-21 Routine/Complete Inspection No Violations Noted John Ley, Water Quality Specialist, SWRO was on site with Mr. Richard Kunkle Engineering Coordinator for Penneco to inspect the site for an OG57 waiver. The site was heavily covered with brush. The well head stake was located and it was where the plan called out. Abbers Creek was located and the area near the #10 well site was dry at the time of the inspection.
2082248 Primary Facility 2012-07-11 Routine/Complete Inspection No Violations Noted John Ley WQS, SWRO was on site to conduct a routine inspection of the above site. Drilling had not yet started. Pad construction was in process. The access road was in good condition. Site ID was posted and the well permit was on site.
2085932 Primary Facility 2012-07-17 Drilling/Alteration No Violations Noted CONTRACTOR IS MOVING DIRT TO BUILD THIS PAD.
2085950 Primary Facility 2012-07-11 Drilling/Alteration No Violations Noted THE SITE IS UNDER CONSTRUCTION. ACCESS IS GOOD.
2093382 Primary Facility 2012-08-08 Drilling/Alteration No Violations Noted WHIPSTOCK IS DRILLING AT 112'. 26" CONDUCTOR IS CEMENTED IN PLACE.
2093422 Primary Facility 2012-08-02 Drilling/Alteration No Violations Noted THE SITE IS BUILT AND E&S CONTROLS ARE IN PLACE.
2095861 Primary Facility 2012-08-15 Drilling/Alteration No Violations Noted US ENERGY DRILLED TO 1500'. LES WILSON WILL FINISH. SITE IS OK.
2096572 Primary Facility 2012-08-22 Drilling/Alteration No Violations Noted TOP HOLE RIG IS GONE. A VENT HAS BEEN INSTALLED. THE SITE IS IN GOOD CONDITION.
2098801 Primary Facility 2012-09-10 Routine/Complete Inspection No Violations Noted John Ley and Sam Steingrabe, WQS, SWRO an were on site to conduct a routine inspection. At the time of the inspection, the well sign, E&S plan, and well permit were on site. BMP's installed were functioning according to the E&S plan. Hillsides were temporarily stabilized and had good growth on them. No accelerated erosion or sedimentation issues were observed on site.
2099816 Primary Facility 2012-09-10 Drilling/Alteration No Violations Noted LES WILSON 25 SETTING UP TO RESUME DRILLING AT 1500'. SITE IN GOOD SHAPE.
2102879 Primary Facility 2012-09-18 Drilling/Alteration No Violations Noted WILSON RIG BUILDING CURVE FOR THE HORIZONTAL LEG OF THIS OIL WELL.
2102891 Primary Facility 2012-09-12 Drilling/Alteration No Violations Noted WILSON RIG DRILLING BOTTOM HOLE.
2106811 Primary Facility 2012-10-01 Drilling/Alteration No Violations Noted DRILLING COMPLETE. RIG DOWN AND MOVING OUT.
2106813 Primary Facility 2012-10-09 Drilling/Alteration No Violations Noted DRILLING COMPLETE. WELL NOT FRACED.
2121257 Primary Facility 2012-12-03 Drilling/Alteration No Violations Noted BAKER TOOL FISHING FOR 4.5" CASING. CASING UNSCREWED WHEN THE BOP WAS REMOVED.
2124790 Primary Facility 2012-12-10 Drilling/Alteration No Violations Noted WORKING TO GET SEPERATED 4.5" CASING BACK TOGETHER. SITE IS IN GOOD SHAPE.
2128210 Primary Facility 2013-01-02 Drilling/Alteration No Violations Noted CONTRACTOR HAS NOT BEEN ABLE TO HOOK UP SEPERATED CASING. A BIGGER RIG WILL TRY TO MILL CASING TO A BETTER SECTION OF PIPE.
2131231 Primary Facility 2013-01-14 Drilling/Alteration No Violations Noted SERVICE RIG IS GONE. NO ACTIVITY TODAY. BIGGER RIG WILL MILL SEPERATED CASING.
2132847 Primary Facility 2013-01-22 Routine/Complete Inspection No Violations Noted John Ley, WQS, SWRO was on site to conduct a routine inspection. At the time of the inspection, the well sign, E&S plan, PPC plan, and well permit were on site. The site was gated for security. BMP's installed were functioning according to the E&S plan. No accelerated erosion or sedimentation issues were observed on site or on the access road.
2143046 Primary Facility 2013-02-04 Drilling/Alteration No Violations Noted WELL IS NOT COMPLETED. ALARGER RIG WILL REPAIR DAMAGED CASING. SITE IS GOOD.
2146618 Primary Facility 2013-03-05 Drilling/Alteration No Violations Noted CONTRACTOR WORKING TO REPAIR SEPERATED 4.5" CASING.
2151179 Primary Facility 2013-03-20 Drilling/Alteration No Violations Noted THIS WELL IS NOW INTACT. WELL IS NOT FRACED. PIT LEVEL IS OK.
2151180 Primary Facility 2013-03-26 Drilling/Alteration No Violations Noted SERVICE RIG IS SET UP. WELL IS BEING PREPARED FOR FRACING.
2156441 Primary Facility 2013-04-08 Drilling/Alteration No Violations Noted WELL IS FRACED AND THE TUBING IS IN. A SERVICE RIG IS MOVING OUT. THE SITE IS OK.
2165005 Primary Facility 2013-04-29 Drilling/Alteration No Violations Noted TUBING AND RODS ARE IN. JACK IS NOT ASSEMBLED. THE PIT IS DRAINED. THE SITE IS OK.
2169266 Primary Facility 2013-05-16 Drilling/Alteration No Violations Noted HORIZONTAL PRODUCING OIL AND GAS WELL. THE JACK IS OPERATING. TRACK HOE BUILDING A DIKE AROUND THE STORAGE TANKS.
2251866 Primary Facility 2014-02-04 Routine/Complete Inspection No Violations Noted JACK IS OPERATING. TANKS ARE DIKED. SITE IS OK.
2391294 Primary Facility 2015-07-01 Routine/Complete Inspection No Violations Noted THIS IS A SHALLOW OIL AND GAS WELL. THE JACK AND PRODUCTION EQUIPTMENT ARE WELL MAINTAINED.
2463824 Primary Facility 2016-03-02 Routine/Complete Inspection No Violations Noted THIS IS A SHALLOW HORIZONTAL OIL AND GAS WELL. THE JACK IS OPERATING.

THE SITE IS IN GOOD CONDITION.

2683657 Primary Facility 2018-01-18 Routine/Complete Inspection No Violations Noted Well drilled and equipped for production. Well tag present. Well apparatus,brine tanks and pump jack appear to be in sound condition. The site was covered with snow. The Department plans to follow up during the spring of 2018 to evaluate vegetative growth.

For data sources see[7]

References