Well Details

Well ID: 37-007-20539
Loading map...
Country: United States
State: Pennsylvania
County: Beaver
Municipality: Marion Township
Operator Name: PENNENERGY RESOURCES LLC
Well Pad ID: 154521
Farm/Lease Name: PER B9 5H
License Status:
Spud Date:
Permit Date: 2017-11-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.790914
Longitude: -80.172269

For data sources see[1][2][3]

Well History

Date Event
2017-11-28 New Permit Application
2018-03-03 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-18 2018-09-26 5,120 13,243,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 92.5 2.13574 2,739,960.0
Hydrochloric Acid (7.5%) PVS Acidizing Listed Below Listed Below 0 0 0
TRS 3001 Tight Rock Solutions Scale Control Listed Below Listed Below 0 0 0
Ammonium persulfate 7727-54-0 100 0.000483277 620
Oxyalkylated alcohol Not Assigned 5 0.00212022 2720.05
Glutaraldehyde 111-30-8 30 0.00535736 6873.01
Hydrotreated Light Distillate Not Assigned 30 0.0127213 16320.3
Hydrochloric Acid 7647-01-0 7.5 0.173168 222159
Amine Triphosphate Not Assigned 30 0.00552351 7086.16
Alcohols C10-16, ethoxylated 0068002-97-1 50 0.000517225 663.553
Alcohol Alkoxylates Not Assigned 5 0.00222468 2854.07
Methanol 0000067-56-1 5 0.00005172 66.355
Inorganic Salt Not Assigned 10 0.00424045 5440.11
Ethylene Glycol 107-21-1 5 0.000920585 1181.03
Butyl digycol 0000112-34-5 75 0.000775838 995.329
Substituted alkylamine Not Assigned 1 0.000424045 544.011
Thiourea 0000062-56-6 1 0.00001034 13.271
Silica Substrate 14808-60-7 100 11.4184 14,648,800.0
Aliphatic Hydrocarbon Not Assigned 30 0.0133481 17124.4
Formaldehyde 0000050-00-0 1 0.00001034 13.271
Sodium Phosphate, Tribasic 7601-54-9 5 0.000920585 1181.03
Water PennEnergy Resources Carrier/Base Fluid Water 7732-18-5 100 86.148 110,520,000.0
TRS 17888 Tight Rock Solutions Friction Reducer Listed Below Listed Below 0 0 0
Unihib G Geosafe Corrosion Inhibitor Listed Below Listed Below 0 0 0
TRS 805X Tight Rock Solutions Friction Reducer Listed Below Listed Below 0 0 0
Sand (Proppant) Sargent/Momentive/Prefferred Proppant Listed Below Listed Below 0 0 0
AP Breaker Lubrizol Breaker Listed Below Listed Below 0 0 0
BIOC12031A Nalco Biocide Listed Below Listed Below 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 PENNENERGY RESOURCES LLC 91,217.00 25 0.00 0 1,333.00 25
2019 PENNENERGY RESOURCES LLC 918,685.00 356 0.00 0 7,416.00 356

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 PENNENERGY RESOURCES LLC Drill Cuttings 852.28 Tons RESIDUAL WASTE PROCESSING FACILITY PAD085690592
2018 PENNENERGY RESOURCES LLC Drilling Fluid Waste 1,127.81 Bbl REUSE (AT WELL PAD)
2018 PENNENERGY RESOURCES LLC Drilling Fluid Waste 420.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2018 PENNENERGY RESOURCES LLC Produced Fluid 102.74 Bbl REUSE (AT WELL PAD)
2018 PENNENERGY RESOURCES LLC Produced Fluid 32.16 Tons RESIDUAL WASTE PROCESSING FACILITY PAD085690592
2018 PENNENERGY RESOURCES LLC Produced Fluid 10.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2018 PENNENERGY RESOURCES LLC Produced Fluid 1.80 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 PENNENERGY RESOURCES LLC Drilling Fluid Waste 720.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2018 PENNENERGY RESOURCES LLC Produced Fluid 176.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 PENNENERGY RESOURCES LLC Produced Fluid 19.43 Bbl INJECTION DISPOSAL WELL 34-155-23196
2019 PENNENERGY RESOURCES LLC Filter Socks 0.49 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2019 PENNENERGY RESOURCES LLC Produced Fluid 19.96 Bbl INJECTION DISPOSAL WELL 34-155-23196
2019 PENNENERGY RESOURCES LLC Produced Fluid 23,623.12 Bbl REUSE (AT WELL PAD)
2019 PENNENERGY RESOURCES LLC Servicing Fluid 11.50 Tons RESIDUAL WASTE PROCESSING FACILITY PAD085690592

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2701382 Primary Facility 2018-03-06 Drilling/Alteration No Violations Noted A 16" conductor has been installed to a depth of 40", and was cemented up into the cellar. The site is being prepared for Highlands rig 9.
2707976 Primary Facility 2018-03-21 Drilling/Alteration No Violations Noted Highlands rig 9 completed top hole drilling. The rig has moved off of this well.
2734806 Primary Facility 2018-05-29 Drilling/Alteration No Violations Noted Patterson 261 is drilling at 5,017' with a 7 7/8" bit.
2737501 Primary Facility 2018-06-05 Drilling/Alteration No Violations Noted Patterson 261 drilled to a depth of 11,757, and cemented 11,737' of 5.5" production casing to the surface.
2742064 Primary Facility 2018-06-15 Routine/Partial Inspection No Violations Noted At time of inspection, there are 6 wells on this site that have been spudded, not yet frac'd. The rig and associated drilling equipment are actively being removed from the location. As a result of this heavy truck traffic and transportation of equipment, the Department is unable to inspect the entire location during today's inspection.
2849951 Primary Facility 2019-03-07 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Three brine tanks within secondary containment and appear structurally sound. GPUs on secondary containment. One AST on-site with signage identifying contents. AST inflow/outflow valve did not have additional spill containment structures. Department recommends Operator install spill containment structures beneath inflow/outflow valves. No E&S issues.