{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.790917,"lon":-80.172197,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Beaver | |
Municipality: Marion Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: 154521 | |
Farm/Lease Name: PER B9 6H | |
License Status: | |
Spud Date: | |
Permit Date: 2017-11-28 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.790917 | |
Longitude: -80.172197 |
Date | Event |
---|---|
2017-11-28 | New Permit Application |
2018-03-04 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-09-11 | 2018-09-18 | 5,332 | 11,615,000 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Unihib G | Geosafe | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 |
TRS 17888 | Tight Rock Solutions | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
TRS 3001 | Tight Rock Solutions | Scale Control | Listed Below | Listed Below | 0 | 0 | 0 | |
BIOC12031A | Nalco | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
Water | PennEnergy Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 85.9223 | 96,927,000.0 | |
Hydrochloric Acid (7.5%) | PVS | Acidizing | Listed Below | Listed Below | 0 | 0 | 0 | |
AP Breaker | Lubrizol | Breaker | Listed Below | Listed Below | 0 | 0 | 0 | |
Sand (Proppant) | Sargent/Momentive/Prefferred | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
Thiourea | 0000062-56-6 | 1 | 0.00001046 | 11.796 | ||||
Oxyalkylated alcohol | Not Assigned | 5 | 0.00175843 | 1983.65 | ||||
Amine Triphosphate | Not Assigned | 30 | 0.00546378 | 6163.57 | ||||
Hydrotreated Light Distillate | Not Assigned | 30 | 0.0105506 | 11901.9 | ||||
Methanol | 0000067-56-1 | 5 | 0.00005229 | 58.982 | ||||
Alcohol Alkoxylates | Not Assigned | 5 | 0.0022693 | 2559.95 | ||||
Substituted alkylamine | Not Assigned | 1 | 0.000351687 | 396.73 | ||||
Ethylene Glycol | 107-21-1 | 5 | 0.000910631 | 1027.26 | ||||
Inorganic Salt | Not Assigned | 10 | 0.00351687 | 3967.3 | ||||
Hydrochloric Acid | 7647-01-0 | 7.5 | 0.175771 | 198283 | ||||
Sodium Phosphate, Tribasic | 7601-54-9 | 5 | 0.000910631 | 1027.26 | ||||
Alcohols C10-16, ethoxylated | 0068002-97-1 | 50 | 0.000522859 | 589.825 | ||||
Ammonium persulfate | 7727-54-0 | 100 | 0.000514149 | 580 | ||||
Aliphatic Hydrocarbon | Not Assigned | 30 | 0.0136158 | 15359.7 | ||||
Formaldehyde | 0000050-00-0 | 1 | 0.00001046 | 11.796 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00531132 | 5991.58 | ||||
Butyl digycol | 0000112-34-5 | 75 | 0.000784288 | 884.737 | ||||
Silica Substrate | 14808-60-7 | 100 | 11.6161 | 13,103,800.0 | ||||
TRS 805X | Tight Rock Solutions | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
Other Chemical(s) | Listed Above | See Trade Name(s) List | Water | 7732-18-5 | 92.5 | 2.16784 | 2,445,490.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | 105,448.00 | 26 | 0.00 | 0 | 682.00 | 26 |
2019 | PENNENERGY RESOURCES LLC | 706,222.00 | 354 | 0.00 | 0 | 1,468.00 | 354 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | Drill Cuttings | 872.89 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Other Oil & Gas Wastes | 60.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 2,662.22 Bbl | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 600.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 134.00 Bbl | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 32.16 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 1.80 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 10.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PENNENERGY RESOURCES LLC | Synthetic Liner Materials | 3.91 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
2018 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 993.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 203.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 19.43 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2019 | PENNENERGY RESOURCES LLC | Filter Socks | 0.49 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 13.58 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 17,250.71 Bbl | REUSE (AT WELL PAD) | |
2019 | PENNENERGY RESOURCES LLC | Servicing Fluid | 11.50 Tons | RESIDUAL WASTE PROCESSING FACILITY | PAD085690592 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2701394 | Primary Facility | 2018-03-06 | Drilling/Alteration | No Violations Noted | A 16" conductor has been installed to a depth of 40", and was cemented up into the cellar. The site is being prepared for Highlands rig 9. |
2703754 | Primary Facility | 2018-03-12 | Drilling/Alteration | No Violations Noted | Rig drilled 10 7/8" hole to total depth of 2530'. Currently circulating hole in preparation of running 2520.74' of 8 5/8" casing. No violations noted. NOVIO |
2737490 | Primary Facility | 2018-06-05 | Drilling/Alteration | No Violations Noted | Patterson 261 is drilling the bottom potion of this well at 3,183'. The KOP will be 4,324' and the LP will be 5,673'. |
2740696 | Primary Facility | 2018-06-13 | Drilling/Alteration | No Violations Noted | Patterson 261 just finished cementing 11,670' of 5.5" production casing. The casing was cemented to the surface. The rig will be moved from the pad. |
2742058 | Primary Facility | 2018-06-15 | Routine/Partial Inspection | No Violations Noted | At time of inspection, there are 6 wells on this site that have been spudded, not yet frac'd. The rig and associated drilling equipment are actively being removed from the location. As a result of this heavy truck traffic and transportation of equipment, the Department is unable to inspect the entire location during today's inspection. |
2849953 | Primary Facility | 2019-03-07 | Routine/Complete Inspection | No Violations Noted | At the time of inspection well equipped for production. Three brine tanks within secondary containment and appear structurally sound. GPUs on secondary containment. One AST on-site with signage identifying contents. AST inflow/outflow valve did not have additional spill containment structures. Department recommends Operator install spill containment structures beneath inflow/outflow valves. No E&S issues. |