X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-019-22713

Well Details

Well ID: 37-019-22713
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Allegheny Township
Operator Name: EM ENERGY PA LLC
Well Pad ID: 154430
Farm/Lease Name: CANIS MAJOR 8-MH
License Status: Plugged and Abandoned
Spud Date: 2018-01-30
Permit Date: 2018-01-05
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.148903
Longitude: -79.724581

For data sources see[1][2][3]

Well History

Date Event
2018-01-05 New Permit Application
2018-01-30 Performed Spud Operation
2018-01-31 Drilling Completion
2018-06-20 Begin Plugging
2018-06-21 Finished Plugging
2018-09-07 Fully Plugged

For data sources see[4]


Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 EM ENERGY PA LLC Other Oil & Gas Wastes 120.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EM ENERGY PA LLC Other Oil & Gas Wastes 20.63 Bbl REUSE (AT WELL PAD)
2018 EM ENERGY PA LLC Drilling Fluid Waste 6.88 Tons REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2687790 Primary Facility 2018-01-29 Administrative/File Review No Violations Noted
2711486 Primary Facility 2018-02-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well has been spud and 20" was set to 98'. Cellars were being set. Emergency Response sign was properly posted as well as the permit sign.
2739246 Primary Facility 2018-06-08 Routine/Partial Inspection No Violations Noted
2742108 Primary Facility 2018-06-14 Routine/Partial Inspection No Violations Noted At the time of inspection, no activity was taking place at the wells. A notification was given that this well would be plugged today. Steel grated plates are covering the well cellar and there are plastic jersey barriers surrounding the well. Cellars are full of water. Spoke to the company man for the site and was told that management requested the plugging to be rescheduled until next week. The Notice of Intent to plug is good for 30 days from the time it was received, but a notification (phone or, preferably, email) will need to be given when plugging will begin.
2744060 Primary Facility 2018-06-20 Plugging(Includes Plugged/Mined Through) No Violations Noted At the time of inspection, conductor was to be filled with gravel and capped. The top 2' of conductor has already been cut off. The cellars and wells were sucked dry yesterday. A water truck was still onsite sucking water out of containment. I was onsite to witness the 8MH and 6MH get plugged, but left because truck had to leave to get another load of stone. The stone was being poured into the well starting at 8:45 AM.

I called company man at 1:30 PM and all conductors and mouse holes were filled in and steel caps welded on top.

2753667 Primary Facility 2018-07-19 Administrative/File Review No Violations Noted

For data sources see[6]

References