37-021-21164

Well Details

Well ID: 37-021-21164
Loading map...
County: Cambria
Municipality: Clearfield Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 146495
Farm/Lease Name: SMITHMYER UNIT 1H
First Permit Date: 2010-08-04
Last Permit Date: 2010-08-04
Spud Date: 2011-05-11
Unconventional: Yes
Configuration: Horizontal
Well Status: ACTIVE
Violations: 1
Latitude: 40.61023
Longitude: -78.5868

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-3 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2013-1 0.0 0.0 0.0 0.0 0.0 0.0
2013-2 0.0 0.0 0.0 0.0 0.0 0.0
2014-1 0.0 0.0 0.0 0.0 0.0 0.0
2014-2 0.0 0.0 0.0 0.0 0.0 0.0
2015-02 0.0 0.0 0.0 0.0 0.0 0.0
2015-01 0.0 0.0 0.0 0.0 0.0 0.0
2015-03 0.0 0.0 0.0 0.0 0.0 0.0
16-Jan 0.0 0.0 0.0 0.0 0.0 0.0
15-Aug 0.0 0.0 0.0 0.0 0.0 0.0
15DECU 0.0 0.0 0.0 0.0 0.0 0.0
15JULU 0.0 0.0 0.0 0.0 0.0 0.0
15MAYU 0.0 0.0 0.0 0.0 0.0 0.0
15OCTU 0.0 0.0 0.0 0.0 0.0 0.0
15OCTU 0.0 0.0 0.0 0.0 0.0 0.0
15SEPU 0.0 0.0 0.0 0.0 0.0 0.0
16APRU 0.0 0.0 0.0 0.0 0.0 0.0
16FEBU 0.0 0.0 0.0 0.0 0.0 0.0
16MARU 0.0 0.0 0.0 0.0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1995968 2011-08-16 No Violations Noted Id sign at entrance. Drilling complete. No rig onsite. Well not yet equipped for production. E&S ok.
1997496 2011-08-16 Viol(s) Noted & Immediately Corrected Site visit was result of spill notification by Nick Staffieri of Chevron on August 13, 2011.

Oil based drilling mud was spilled on containment (approximately 1 barrel). Spill was contained and removed. Upon its removal a hole in the containment liner was observed. It was determined that approximately five gallons of mud made it to the pad. At time of the inspection ES&G Environmental and Moody and Associates were doing an analysis of the spill area following Act 2 parameters. All contaminated materials were in sealed roll of boxes.

618424 78.54 - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth.
2002450 2011-09-13 No Violations Noted Drilling complete. Id sign and e&s plan ok. No rig onsite.
2003118 2011-09-02 No Violations Noted At the time of inspection, well sign, ES plan, and ESCGP-1 present. Access road adequately rocked and stable. Site gated with 24 hr security onsite. Well drilled, not yet in production. BMPs installed and functioning properly. No accelerated erosion or sedimentation observed. Site has been temporarily seeded and mulched providing temporary stabilization. Five frac tanks located onsite, noted that one tank was left with a hose attached (Chevron Rep Nick Staffieri contacted). Observed that area of previously reported spill has been cleaned up, yet disturbed areas have not yet been restored as operator is awaiting final analysis results to confirm all contaminates have been removed. A follow up inspection will be conducted to ensure that previously impacted areas have been successful remediated.
1972639 2011-05-13 No Violations Noted At the time of inspection, well sign (permit #), ES plan, and ESCGP-1 located onsite. Well spud 05/11/11. Access road stable. Rig located onsite actively drilling. Site secured by fence and 24hr security. Observed temporary (lined) containment pad located beneath rig in order to prevent/contain a possible pollution event. Temporary BMP﾿s installed according to ES plan. All culverts, outlets, and sediment traps appear adequately rocked. No accelerated erosion/sedimentation or IW issues are noted. Operator should continue to routinely monitor/maintain all BMP﾿S until final site restoration is achieved. All previously disturbed areas have been stabilized with vegetative blankets, with some growth observed. Soil pile has been temporarily seeded, minimal growth observed, although compost sox installed down gradient. No violations noted during this inspection.
1975379 2011-05-18 No Violations Noted At the time of inspection, no E&S or IW discharge issues at the site. Chief hired UDI rig. Dewayne Pauley is the company representative. Conductor pipe set at 69 ft using 20﾿ pipe. First stringer set at 679 ft with 13 3/8﾿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8﾿ pipe with 585 sks and 15 bbl return. Current depth was at 2,300 feet. Pilot hole set for 9000 ft. E&S controls were in place.
1986001 2011-06-28 No Violations Noted At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe set at 69 ft using 20﾿ pipe. First stringer set at 679 ft with 13 3/8﾿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8﾿ pipe with 585 sks and 15 bbl return. Current depth was at 9263 feet. Cement plug was set back to 8500 ft approximately 737 ft. and used 300 sks of Class A cement. Wire line Survey was completed of the well. Horizontal leg scheduled for 4699 feet. E&S controls were in place.
1986053 2011-06-01 No Violations Noted At the time of inspection, no E&S or IW discharge issues at the site. Chief hired UDI rig. Dewayne Pauley is the company representative. Conductor pipe set at 69 ft using 20﾿ pipe. First stringer set at 679 ft with 13 3/8﾿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8﾿ pipe with 585 sks and 15 bbl return. Current depth was at 9250 feet. Bridge plug set at 1700 ft. with 10ft cement plug on top of plug. E&S controls were in place.
2040799 2012-01-31 No Violations Noted At the time of inspection, no E&S issues were present at the site. Gas well was not in production. Chevron was called by DEP to change well sign from Chief to Chevron.


2093223 2012-07-18 No Violations Noted At the time of inspection, no E&S issues were present at the site. Gas well was not in production.


2148481 2013-03-07 No Violations Noted On-site meeting with Chevron rep Curtis Small.

Well granted inactive status on 6/8/2012. Drilled, not yet frac'd. Well tag present. Tank on containment. Silt socks were removed at request of landowner. Site appears temporarily stabilized and no E&S issues observed although site snow-covered. Access road in good condition. Prior agreement with Department to begin restoration activities in spring 2013. At that time, Operator will remove 3 sed traps, soil pile will be used to restore cut slope, two collection ditches will remain, and gravel pile next to cut slope will be spread out. Department rep Samantha Foulk field-approved change to E&S plan. Upon completion of driling operations, topsoil will not be spread over the pad, the pad will remain rocked, and the pad size will not change.

2223649 2013-11-20 No Violations Noted Production equipment on site, though well not in production at time of inspection. Site surrounded by fence, gated off. Site ID located on access road. Pad is not vegetated and remains stone-covered. Production equipment and brine tank surrounded by gate. Tank is on lined secondary containment. Tank appears sound. Two stockpiles of stone on site. Well spudded on 5/11/13, granted inactive status on 6/08/12. Dept. spoke to two reps from Chevron who arrived on site during inspection. Discussed well history and plans for restoration work. No E&S issues observed and access road is in good condition.
2321577 2014-11-13 No Violations Noted Marcellus. At time of inspection
2325389 2014-12-01 No Violations Noted Marcellus. At time of inspection
2334723 2014-12-30 No Violations Noted Well is inactive. At the time of
2349913 2015-03-04 No Violations Noted At time of inspection

For data sources see[2]

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2011-1 DRILL CUTTINGS 695.88 Tons LANDFILL 101534 LAUREL HIGHLANDS LANDFILL JOHNSTOWN PA
2011-1 DRILL CUTTINGS 194.71 Tons LANDFILL 101421 SHADE LANDFILL CAIRNBROOK PA
2011-1 DRILLING FLUID WASTE 720.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163 PATRIOT WATER TREATMENT WARREN OH

For data sources see[3]

References