37-033-26256

Well Details

Well ID: 37-033-26256
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Huston Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: DUBOIS 3575 6
License Status: ACTIVE
Spud Date:
Permit Date: 2006-10-26
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.169232
Longitude: -78.578299

For data sources see[1][2][3]

Well History

Date Event
2006-10-26 New Permit Application
2007-03-13 Performed Spud Operation
2007-03-15 Drilling Completion
2007-05-01 Perforation
2007-08-31 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2005 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2006 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2007 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2008 EXCO RESOURCES PA INC 3094.00 366 0.00 0 0.00 0
2009 EXCO RESOURCES PA INC 2626.00 365 0.00 0 0.00 0
2010 EXCO RESOURCES PA INC 2,801.00 365 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 1,797.00 365 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 2,040.00 366 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 1,611.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 1,431.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 1,299.34 332 0.00 0 0.00 0
2016 ALLIANCE PETRO CO LLC 1,278.00 183 0.00 0 0.00 0
2017 ALLIANCE PETRO CO LLC 513.00 365 0.00 0 0.00 0
2018 ALLIANCE PETRO CO LLC 101.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 EXCO RESOURCES PA INC Brine 93.00 Bbl Brine or Industrial Waste Treatment Plt PA0101397
2009 EXCO RESOURCES PA INC Brine 114.00 Bbl Injection Disposal Well PAS2D205BCLE
2009 EXCO RESOURCES PA INC Brine 36.00 Bbl Brine or Industrial Waste Treatment Plt PA0101397
2010 EXCO RESOURCES PA INC Produced Fluid 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2011 EXCO RESOURCES PA INC Produced Fluid 40.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2012 EXCO RESOURCES PA LLC Produced Fluid 40.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2013 EXCO RESOURCES PA LLC Produced Fluid 55.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2013 EXCO RESOURCES PA LLC Produced Fluid 55 Bbl CENT WASTE TRT FAC NPDES PA0095273
2014 EXCO RESOURCES PA LLC Produced Fluid 50.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2015 EXCO RESOURCES PA LLC Produced Fluid 50.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1608495 Primary Facility 2007-03-16 Drilling/Alteration No Violations Noted NO E&S PROBLEMS.
1641110 Primary Facility 2007-07-10 Routine/Complete Inspection No Violations Noted WELL IN LINE PRODUCING
2159378 Primary Facility 2013-04-18 Site Restoration No Violations Noted
2503268 Primary Facility 2016-07-21 Routine/Complete Inspection No Violations Noted
2824342 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at Alliance Petroleum Corporation's conventional well (033-26256) on January 9, 2019. The area surrounding the production equipment has been restored. Restored site is well vegetated. No signs of E&S issues. Brine tank is labeled with the well permit number. A digital chart recorder was observed onsite. No readings were observed on the chart recorder. Flakey paint and corrosion were observed on the well head, separator, and axillary piping. The Department recommends monitoring the production equipment and replacing and/or repainting the equipment if necessary. Department staff used an Altair 5x gas meter during the inspection. No combustible gases or methane were detected.

No violations noted.

For data sources see[7]

References