X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24140

Well Details

Well ID: 37-051-24140
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Henry Clay Township
Operator Name: LPR ENERGY LLC
Well Pad ID: 146975
Farm/Lease Name: JOHN HOLT
License Status: Inactive
Spud Date: 2009-04-02
Permit Date: 2008-12-24
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 39.768936
Longitude: -79.504661

For data sources see[1][2][3]

Well History

Date Event
2008-12-24 New Permit Application
2009-04-02 Performed Spud Operation
2009-04-23 Drilling Completion
2009-10-26 NEWLY DRILLED
2019-12-17 Inactive Well Request Granted

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2009 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2016 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0
2017 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0
2019 LPR ENERGY LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CHIEF OIL & GAS LLC Drilling 1,841.00 Bbl Brine or Industrial Waste Treatment Plt PA0091472
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 50.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHIEF OIL & GAS LLC Drill Cuttings 35.74 Tons LANDFILL 100592
2011 CHIEF OIL & GAS LLC Drill Cuttings 47.87 Tons LANDFILL 100172
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 12,170.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 220.00 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1781524 Primary Facility 2009-03-10 Drilling/Alteration No Violations Noted Marcellus Well spudded, 20" conductor in ground and cemented, no equipment on site
1783500 Primary Facility 2009-04-10 Routine/Complete Inspection No Violations Noted The drilling of the HORIZONTAL MARCELLUS (9500 feet) is still in progress. The below grade pit has been properly installed and is maintaining 2 feet of freeboard. There is no sign of accelerated erosion and sedimentation noted on the access road or well site. Operator should continue to monitor the access road and well site for erosion and sedimentation. Accompanied Greg Higgins for training.
1785888 Primary Facility 2009-04-02 Drilling/Alteration No Violations Noted Marcellus Well, 72 feet of 20 inch ce,emted in, triple ready to drill
1798456 Primary Facility 2009-04-15 Drilling/Alteration No Violations Noted Horizontal Marcellus changed to verticle, site pit e/s ok
1804054 Primary Facility 2009-06-02 Routine/Complete Inspection No Violations Noted Drilling had been completed at the time of the inspection. Below grade pit located onsite and had more than the two feet of required freeboard. No accelerated erosion & sedimentation was observed in relation to the access road or well-site at the time of the inspection.
1821988 Primary Facility 2009-08-20 Routine/Complete Inspection No Violations Noted drilling complete/E&S advice/ID&pit ok/rathole advice
2107173 Primary Facility 2012-10-12 Routine/Complete Inspection No Violations Noted ID sign up, E&S and PPC in box. Site gated and fenced off. Well head and small tank is all that is on site. Pad restored to smaller size, No accelerated erosion issues at this time. Well was labeled.
2205816 Primary Facility 2013-09-19 Routine/Complete Inspection No Violations Noted Well is inactive, well labeled, no leaks, site stable, new Act 9 sign in place.
2627021 Primary Facility 2017-06-28 Routine/Complete Inspection No Violations Noted Routine Inspection , One year Inactive Status Extension meets (DEP) requirments (6/26/2017) . The new operator presented info on future pipe line installation.The well is Shut - In and secure at this time.
2819650 Primary Facility 2019-04-01 Compliance Evaluation No Violations Noted This is an inactive status compliance inspection. The well is tagged, fenced in and not stimulated yet. The well head casing and poly fluid collection tank look ok. A follow up inspection will be conducted on this well after the inactive status has expired.

For data sources see[7]

References