X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24421

Well Details

Well ID: 37-051-24421
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: North Union Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148935
Farm/Lease Name: MUTNANSKY UNIT 10H
License Status:
Spud Date:
Permit Date: 2011-01-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.945842
Longitude: -79.719839

For data sources see[1][2][3]

Well History

Date Event
2011-01-24 New Permit Application
2011-03-31 Performed Spud Operation
2011-05-12 Drilling Completion
2011-11-23 Drilling Completion
2012-02-03 Perforation
2012-02-03 Performed Stimulation
2016-04-11 DEVIATED
2016-04-11 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-02-14 2012-02-14 7,122 3,222,418

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00738000
Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00123000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00 0.00890000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00670000
Proppant (lbs) Proppant 8.39 9.05
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00866000
Clean Volume (gals) Carrier/Base Fluid 91.61 100.00
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00727000
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00018000
Hemicellulase enzyme 9012-54-8 15.00 0.00003000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.32

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-02-03 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 125,898.00 214 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 153,503.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 129,138.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 105,951.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 85,624.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 81,888.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 73,610.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 55,304.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,160.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 9,462.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 5,025.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 2,622.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 0.07 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 190.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 31,917.95 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,632.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 16.25 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 740.25 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 428.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 176.25 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 26.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 62.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 106.75 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Synthetic Liner Materials 1.01 Tons LANDFILL 100663
2018 CHEVRON APPALACHIA LLC Produced Fluid 166.25 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 164.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 356.97 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1961154 Primary Facility 2011-03-28 Routine/Complete Inspection No Violations Noted
1970545 Primary Facility 2011-05-03 Routine/Complete Inspection No Violations Noted
1973588 Primary Facility 2011-05-17 Routine/Complete Inspection No Violations Noted
1979124 Primary Facility 2011-06-08 Routine/Complete Inspection No Violations Noted
1984165 Primary Facility 2011-05-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S AND PITS LOOK IN GOOD CONDITION. TD @ 2749', CEMENTING TONIGHT.
1984168 Primary Facility 2011-05-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,E&S AND PITS IN GOOD CONDITION.YOST #5 RUNNING COAL STRING TODAY AND CEMENTING TONIGHT.
1984173 Primary Facility 2011-05-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S IN GOOD CONDITION. YOST # 5 RUNNING SURFACE CASING TODAY AT 277' AND CEMENTING.
1984180 Primary Facility 2011-05-04 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S AND PIITS LOOK IN GOOD CONDITION. CONDUCTOR SET @ 60'.
1984185 Primary Facility 2011-04-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S LOOK IN GOOD CONDITION.WORKING ON CELLARS TODAY.
1991491 Primary Facility 2011-07-28 Routine/Complete Inspection No Violations Noted
1995656 Primary Facility 2011-08-15 Routine/Complete Inspection No Violations Noted
2005019 Primary Facility 2011-08-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS ,E&S & PITS IN GOOD CONDITION. CROWN # 5 MOVING ONTO LOCATON (8/13/2011). DRILLING ON FLUID @ 4999' TODAY (8/15/2011).
2005027 Primary Facility 2011-08-17 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS ,E&S & PITS IN GOOD CONDITION.CROWN # 5 TD @ 7106'. MUDDED UP AND CAPPED, (MOVING OFF)
2015127 Primary Facility 2011-10-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON - 325 DRILLING ON (MUTNANSKY 11 -H ).
2025500 Primary Facility 2011-11-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 324 DRILLING ON FLUID @ 11,000', RUNNING PROD. CASING AND CEMENTING DURING THIS PAST WEEKEND.
2025504 Primary Facility 2011-11-10 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 324 MOVING ON TO MUTNANSKY 10 -H ,STARTING (11/9/2011).
2144414 Primary Facility 2013-03-01 Routine/Complete Inspection No Violations Noted Site ID sign in place, E&S, PPC, permits in box. Site mostly restored, wells labeled, tanks in containment. Some silt fence in field remaining from previous sed trap removal. No leaks observed today.
2223538 Primary Facility 2013-11-20 Routine/Complete Inspection No Violations Noted On 11/20/2013, the Department performed an Notice of Termination inspection at the site of Chevron Appalachia’s Mutnansky Unit 9, 10, 11, 12H well site in North Union Twp., Fayette County. The ESX10-051-0011 is the site permit being inspected for the N.O.T.
2373085 Primary Facility 2015-05-15 Routine/Complete Inspection No Violations Noted
2421517 Primary Facility 2015-10-14 Routine/Complete Inspection No Violations Noted
2483686 Primary Facility 2016-04-26 Routine/Complete Inspection No Violations Noted

On 10/14/15 I conducted a complaint inspection of the Mutnansky Unit in response to a complaint alleging that erosion had occurred at the site. At the time of inspection significant accelerated erosion was present. It was highly recommended that the issues present be addressed. I met with Mike Herman of Chevron at the site and he indicated that Chevron would be moving forward to address the issues at the site.

On 04/26/16 at approximately 1330 hours I conducted a routine complete inspection of the Mutnansky Unit. The Act 9 sign was in place and all required documents were present at the site. The accelerated erosion noted on 10/14/15 had not been repaired. It appears that a location part way up the pad slope was saturated and was the origin of the accelerated erosion. It is highly recommended that this be investigated.

2560510 Primary Facility 2017-01-27 Routine/Complete Inspection No Violations Noted On 01/27/17 at approximately 1300 hours I conducted a follow up inspection of the Mutnansky Unit. An NOV had been issued on 04/26/16 for 102.22(a). On the date of inspection the Act 9 sign was in place and all required documents were on site.
The majority of the site was well vegetated. The erosion noted in the NOV had been repaired, but erosion channels and what appeared to be tire tracks were present in the location of the repairs. BMPs were in place and sediment was not observed leaving the site. It is recommended that these issues be addressed once weather conditions permit.
2624000 Primary Facility 2017-08-07 Compliance Evaluation No Violations Noted The Act 9 sign was in place and all required documents were present at the site. Previously, water was seeping out of the pad slope causing erosion in the natural swale. The erosion was repaired, but earthmoving equipment tracks and ruts were still visible. The ruts were repaired and the area was seeded and mulched. The site overall was well vegetated with the exception of this area. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2825572 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[9]

References