37-059-25651

Well Details

Well ID: 37-059-25651
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Jefferson Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148678
Farm/Lease Name: KIEFFER UNIT 4H
License Status:
Spud Date:
Permit Date: 2010-12-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.961519
Longitude: -80.030703

For data sources see[1][2][3]

Well History

Date Event
2010-12-27 New Permit Application
2011-03-08 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-01-23 2012-01-23 7,434 3,372,836

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant (lbs) Proppant 9.24 10.20
Iron Control A Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00642000
Scale Inhibitor A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00683000
Clean Volume (gals) Carrier/Base Fluid 90.76 100.00
CMHPG Ashland Water Viscosifier Carboxymethylhydroxyporoyl guar blend 100.00 0.00163000
Unislik ST 50 CESI Chemical Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.26
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00686000
Polyethylene glycol 25322-68-3 60.00 0.01
Dibromoacetonitrile 3252-43-5 5.00 0.00114000
GBL Clearwater International Gel Breaker Ethylene glycol 107-21-1 60.00 0.00002000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 364,234.00 153 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 791,115.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 473,315.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 338,053.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 272,985.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 230,470.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 194,754.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 161,704.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,330.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 11,805.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 7,456.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 1,279.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,065.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 90.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 3,215.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,096.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 706.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 344.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 268.68 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 41.67 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 68.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 36.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 3,325.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 76.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 181.66 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 141.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 453.33 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1970196 Primary Facility 2011-03-09 Routine/Complete Inspection No Violations Noted
1974946 Primary Facility 2011-03-29 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The site contains 1 drilling pit at this time. The Operator plans on constructing another pit and 2 additional impoundments for frac water. The pit that is half completed on site does contain water and groundwater is a concern. The pit/impoundments need to be constructed 20 inches above the seasonal high groundwater table. The Department may want to observe the pit that is being used at this time to hold cuttings after the liner is removed to be sure groundwater was not impacted.
1974963 Primary Facility 2011-04-01 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The Operator is currently drilling top-hole on site. The Department met on site with the Operator and a Gateway Engineer to discuss the ESCGP-1 and the impoundment. The Engineer was on site to make sure the contractors were following the construction standards of 3:1 slopes and also checking the 8 inch lifts. The contractors were installing drains on site so the springs did no impact the well pad. The Department also mentioned the drill pits and the concern that they may be close to the seasonal high groundwater table.
1991577 Primary Facility 2011-07-06 Drilling/Alteration No Violations Noted
2001313 Primary Facility 2011-05-17 Routine/Complete Inspection No Violations Noted
2027494 Primary Facility 2011-09-06 Routine/Complete Inspection No Violations Noted
2036448 Primary Facility 2012-01-09 Routine/Complete Inspection No Violations Noted
2120628 Primary Facility 2012-11-15 Routine/Complete Inspection No Violations Noted Wells drilled and in production. Site restored and greater than 70% growth. Site in overall good condition.
2195703 Primary Facility 2013-08-12 Routine/Complete Inspection No Violations Noted Routine inspection. Well cmpliant at time of inspection.
2314875 Primary Facility 2014-09-16 Routine/Complete Inspection No Violations Noted On 9/16/2014, I performed an inspection of Chevron Kieffer well pad site. The site is located in Dunkard Twp., Greene County. The inspection was performed as a restoration inspection and request by operator for a termination of the ESCGP permit.
2318077 Primary Facility 2014-08-28 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance.
2488221 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS, Routine Inspection all looks good.
2509267 Primary Facility 2016-08-09 Routine/Complete Inspection No Violations Noted

On 08/09/16 at approximately 1430 hours I conducted a routine complete inspection of the Chevron Appalachia LLC Kieffer well site. The Act 9 sign was in place and all required documents were present at the site. The well pad was fenced, gated, and locked at the time of inspection.

Chevron had recently submitted a minor modification and Environmental Engineering Specialist Mohamed Sam found that the last major modification for the site was approved on 12/21/2010. As a result, the ESCGP-1 expired on 12/20/2015 with no record of an extension being requested or approved. An NOT was completed by WQS Ben Dillie on 10/09/2014 and in the report Dillie indicated the NOT was denied due to the well pad having not been reclaimed to post construction design. A violation of 102.7(c) has occurred for failure to terminate or renew the ESCGP.

An overlay exhibit submitted with the minor modification shows that the access road was not built in the permitted location. This is a violation of 102.5(m)(4). Additionally, an u

For data sources see[8]

References