If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-21353 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.329178,"lon":-76.826483,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Upper Fairfield Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 145739 | |
Farm/Lease Name: ALLEGHENY RIDGE EAST EICHENLAUB | |
License Status: Plugged and Abandoned | |
Spud Date: 2013-12-04 | |
Permit Date: 2013-10-31 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.329178 | |
Longitude: -76.826483 |
Date | Event |
---|---|
2013-10-31 | New Permit Application |
2013-11-12 | Newly Drilled |
2013-12-05 | Drilling Completion |
2013-12-05 | Performed Spud Operation |
2017-05-22 | Begin Plugging |
2017-05-22 | Finished Plugging |
2017-07-11 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | INFLECTION ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2241697 | Primary Facility | 2014-02-03 | Routine/Complete Inspection | No Violations Noted | |
2259534 | Primary Facility | 2014-03-24 | Routine/Complete Inspection | No Violations Noted | |
2287018 | Primary Facility | 2014-07-09 | Drilling/Alteration | No Violations Noted | |
2292002 | Primary Facility | 2014-07-31 | Routine/Complete Inspection | No Violations Noted | |
2334542 | Primary Facility | 2015-01-07 | Routine/Complete Inspection | No Violations Noted | |
2554224 | Primary Facility | 2017-01-12 | Routine/Complete Inspection | No Violations Noted | I entered the site and noted two wells in production (081-21246 and 081-20355). Records indicate the two other cellars have conductor only but I did not observe the conductor since the cellars were filled with gravel. Water from the well pad surface was flowing into drop inlets on the northwest and southwest corners of the well pad and flowing into ditches which flowed into the sedimentation basin. The concrete riser and dewatering structure was not functioning properly since water was seeping into the riser from around the outlet pipe and the dewatering structure was out of the water. Sediment laden water was observed flowing into the basin and out but was able to infiltrate. I recommend monitoring the E&S conditions onsite. No Violations Noted. |
2564364 | Primary Facility | 2017-02-22 | Routine/Complete Inspection | No Violations Noted | Well cellar filled with gravel. |
2570908 | Primary Facility | 2017-03-13 | Administrative/File Review | Violation(s) Noted | Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
Well was plugged and the Plugging Certificate was reviewed and approved. VIOL resolved as CRCTD on the date the PLUGC was approved (7/5/2017). ~CMB~ |
2610474 | Primary Facility | 2017-07-05 | Administrative/File Review | No Violations Noted | July 5th 2017: Certificate of Well Plugging for this conductor has been received, reviewed, signed, and sent to file. |
2637774 | Primary Facility | 2017-09-19 | Routine/Complete Inspection | No Violations Noted | Four wells on pad: 2 in production and two or conductor only. The conductor-only wells are the Eichenlaub B 2 and the Eichenlaub B These wells may be plugged. I need to check back in the office. The Eichenlaub 1H Who is in production. No gas was detected on any of the three annular vents. Monitoring was conducted using Altair 5X gas meter calibrated on September 19, 2017. The Biddle Eichenlaub B 4 was also in production. No gas was detected on any of the three annular vents. The result of this inspection is, no violations. |
2673376 | Primary Facility | 2017-12-20 | Routine/Complete Inspection | No Violations Noted | Arrived at14:50. Weather: windy, getting colder. 2 producing eells on the pad and 2 conductors. No gas detected at annuli No violations observed. |
2855537 | Primary Facility | 2019-03-19 | Routine/Complete Inspection | No Violations Noted | Two wells staged for production. Two plugged wells (081-21356 and 081-21353). Two GPUs within containment. No leaks from production equipment. A stormwater basin was recently installed at the west end of the pad. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2570908 | 780484 | 2017-03-13 | 2017-07-05 | 78a91(a) | Environmental Health & Safety | The Allegheny Ridge East Eichenlaub B 3 well was spud December 5, 2013 and was drilled to a depth necessary to set conductor casing under the authorization of well permit number 081-21353. The well permit for 081-21353 expired October 31, 2014. The well remains a conductor and has had no drilling |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
780484 | 351610 | NOV - Notice of Violation | 2017-07-05 |