X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20036

Well Details

Well ID: 37-115-20036
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147190
Farm/Lease Name: COSTELLO 1
License Status: ACTIVE
Spud Date:
Permit Date: 2008-03-26
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.728214
Longitude: -75.879091

For data sources see[1][2][3]

Well History

Date Event
2008-03-26 New Permit Application
2008-07-16 Performed Spud Operation
2008-09-30 Perforation
2008-09-30 Performed Stimulation
2008-10-14 Drilling Completion
2009-02-27 NEWLY DRILLED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2008-09-30 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 CABOT OIL & GAS CORP 40299.00 70 0.00 0 0.00 0
2009 CABOT OIL & GAS CORP 110761.00 365 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 68,047.50 366 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 32,605.00 365 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 30,531.00 317 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 5,560.00 35 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 CABOT OIL & GAS CORP Brine 100.00 Bbl Brine or Industrial Waste Treatment Plt PA0026034
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 158.80 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Produced Fluid 18.52 Bbl REUSE OTHER THAN ROAD SPREADING
2010 CABOT OIL & GAS CORP Drill Cuttings 78.20 Tons LANDFILL 8-4630-00010/00
2010 CABOT OIL & GAS CORP Basic Sediment 1.85 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 95.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drill Cuttings 48.10 Tons LANDFILL 101247
2010 CABOT OIL & GAS CORP Drill Cuttings 13.60 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Drill Cuttings 78.20 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drill Cuttings 1.00 Tons LANDFILL 100955
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 240.52 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Basic Sediment 0.26 Bbl LANDFILL 101534
2011 CABOT OIL & GAS CORP Produced Fluid 57.25 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.66 Tons LANDFILL 100081
2013 CABOT OIL & GAS CORP Servicing Fluid 2,615.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Servicing Fluid 326.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Servicing Fluid 58.56 Bbl LANDFILL THR029
2013 CABOT OIL & GAS CORP Produced Fluid 39.76 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Servicing Fluid 846.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Servicing Fluid 299.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2014 CABOT OIL & GAS CORP Servicing Fluid 848.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 20.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Servicing Fluid 2,655.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Synthetic Liner Materials 4.65 Tons LANDFILL 101247

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1713937 Primary Facility 2008-06-03 Routine/Complete Inspection Violation(s) Noted
1716866 Primary Facility 2008-06-26 Routine/Complete Inspection No Violations Noted
1723234 Primary Facility 2008-07-17 Routine/Complete Inspection No Violations Noted
1723235 Primary Facility 2008-07-24 Routine/Complete Inspection No Violations Noted
1726691 Primary Facility 2008-08-06 Routine/Complete Inspection No Violations Noted
1728610 Primary Facility 2008-07-30 Drilling/Alteration No Violations Noted
1733018 Primary Facility 2008-08-06 Drilling/Alteration No Violations Noted
1753522 Primary Facility 2008-10-31 Routine/Complete Inspection No Violations Noted
1764350 Primary Facility 2009-01-20 Routine/Complete Inspection No Violations Noted
1765373 Primary Facility 2009-01-21 Routine/Complete Inspection No Violations Noted
1765482 Primary Facility 2009-01-26 Routine/Complete Inspection No Violations Noted
1765484 Primary Facility 2009-01-27 Routine/Complete Inspection No Violations Noted
1769075 Primary Facility 2009-02-02 Drilling/Alteration No Violations Noted
1769076 Primary Facility 2009-02-03 Drilling/Alteration No Violations Noted
1769078 Primary Facility 2008-02-10 Routine/Complete Inspection No Violations Noted
1769108 Primary Facility 2009-02-11 Routine/Complete Inspection No Violations Noted
1769143 Primary Facility 2008-02-10 Routine/Complete Inspection No Violations Noted
1774894 Primary Facility 2009-02-18 Administrative/File Review Violation(s) Noted
1778901 Primary Facility 2009-03-18 Routine/Complete Inspection No Violations Noted
1799547 Primary Facility 2009-05-13 Routine/Complete Inspection No Violations Noted
1833423 Primary Facility 2009-09-25 Follow-up Inspection No Violations Noted An existing road was used to access the well site. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, the drill rig was offsite. The area around the well has been reclaimed. The well is producing.
1835385 Primary Facility 2009-10-14 Follow-up Inspection No Violations Noted The inspection was completed as a follow up of a previous inspection performed on 9/25/09 where gas seepage was observed in between the 7" and 9-5/8" casings of the well. During this inspection, a small amount of standing water was present around the base of the well. Minor gas seepage was observed between the 7" and 9-5/8" casings of the well.
1890414 Primary Facility 2010-05-24 Routine/Complete Inspection No Violations Noted
1960308 Primary Facility 2011-03-22 Routine/Complete Inspection Violation(s) Noted NERO EC&B Act 2 ROL granted 7/5/11. MBC data cleasn-up 3/30/15.
1966956 Primary Facility 2011-04-12 Follow-up Inspection Outstanding Violations - No Viols Req'd
2050946 Primary Facility 2012-03-13 Site Restoration No Violations Noted
2139922 Primary Facility 2013-02-14 Follow-up Inspection No Violations Noted On site at 10 am to collect pressure reading and isotopic gas sample from annulus of well. DEP reps on site were Steve Watson, Eric Rooney, and Gene Rickard. DEP met with Mr. John Smelko of Cabot. Selman reps on site to assist in gas readings and to split gas samples. Cabot shut in annulus at 9 am this morning. At 10:23 am a digital pressure gauge was installed on the 7 x 4" annulus. Pressure = 23.7 psi. Gauge was removed and open vent was screened for gas. Model 60 reading = >5% combustible gas, and recorded 100% LEL. Prior to sampling, fluid was drained from vent line. Both DEP and Cabot collected gas samples for isotopic analysis. After completion of sampling, Cabot re-connected vent line and locked vent open. Cabot is planning on moving in a workover rig this week to service well.
2144867 Primary Facility 2013-02-26 Drilling/Alteration No Violations Noted run hornet packer to 6600
2144877 Primary Facility 2013-03-03 Drilling/Alteration No Violations Noted reset hornet packer 6579' with 35' ext.
2144905 Primary Facility 2013-03-04 Drilling/Alteration No Violations Noted elec. gauge on 7x4.5 shows 0 mcf same with 2 3/8x 4.5
2148890 Primary Facility 2013-03-18 Drilling/Alteration No Violations Noted perfs 2868-2874' injection 15% hcl none got away at 1500psi
2181415 Primary Facility 2013-07-08 Drilling/Alteration No Violations Noted 0 mcf flow on either annuli
2184666 Primary Facility 2013-07-16 Drilling/Alteration No Violations Noted see accompaning hard copy daily procedure in master file
2185362 Primary Facility 2013-07-21 Complaint Inspection No Violations Noted Arrive at site 13:00 hrs, walked entire operation and pad,found no spills leakes or any situations pertaing to nature of complaint.
2185632 Primary Facility 2013-07-23 Drilling/Alteration No Violations Noted packer set at 1610 no gas in tubing (slight vacuum) 25lbs on 2 3/8x 4 1/4
2308515 Primary Facility 2014-09-24 Drilling/Alteration No Violations Noted
2310437 Primary Facility 2014-10-03 Drilling/Alteration No Violations Noted
2315385 Primary Facility 2014-10-22 Drilling/Alteration No Violations Noted
2319456 Primary Facility 2014-11-05 Drilling/Alteration No Violations Noted At time of inspection, arrived at site at: 12:00 hrs. Onsite to perform routine inspections of wells / wellsites and document signage present at both Costello well pads. (Pad #1 and 2) On the Costello Pad #1: The Costello 1V well is presently being monitored by Cabot. Met w/ Cabot Co. Man Jim Restly. Stone Energy Services Rig is still onsite after milling out 7" casing from wellbore. Well was loaded with fresh water back on 10/28/14 and has been monitored since. No flow or gas was detected at flow unit at time of inspection. Site and containment were found in good condition. Well tags and Entry signage were in place and up to date for both pads.
2435373 Primary Facility 2015-09-30 Routine/Complete Inspection No Violations Noted
2509181 Primary Facility 2016-08-04 Complaint Inspection No Violations Noted At time of inspection, arrived on site at 12:35p.m. pertaining to a complaint called into the department about a backhoe and a dumpster being hauled onto the site and unknown activity. There was no activity on the site at time of inspection, there was no backhoe on site but there were two role off containers on site. The marks on the entrance road indicated that the containers have recently been dropped off.

I left the site at 12:45p.m.

2528794 Primary Facility 2016-10-11 Site Restoration No Violations Noted Inspection of the Costello J P1 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. Post Construction Stormwater Management BMPs appear to be installed properly according to the site restoration plans. The well pad is less than or equal to the size indicated on the site restoration plans.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2639361 Primary Facility 2017-09-21 Routine/Complete Inspection No Violations Noted Arrived at site at:12:15. Weather conditions: Sunny, warm, ~80 degs. Onsite to perform routine insp of the Costello 1V well, the only well drilled on this pad. Most recent remedial activities were completed on this well back in Sept. and Oct. of 2014. This remedial work included; - Removal of ~ 1776' of 4 1/2" csg. and milling the entire 7" Intermediate casing string, approx. 1500', out of wellbore. Following this work wellhead was connected to Total Flow Control Unit (TFCU) to monitor any venting that may be occurring. At time of inspection reading taken off the TFCU showed no measureable vent flow detected ¿Static¿, with a cumulative reading of 12.75 cf/d. (See attached pic# 2). Vent line from TFCU was ran to a small poly vent tank. A gas check was performed in the vent tank lid opening showed, 58% LEL, 2% CH4. A gas check performed ~ 3¿ away from vent tank at ~ 5¿ above ground level showed 0% LEL, 0% CH4. No indications of recent activities were observed at site and no further concerns were noted. No
2674260 Primary Facility 2017-12-22 Administrative/File Review No Violations Noted I approved a restoration report on December 19, 2017 for this well site.
2749454 Primary Facility 2018-07-05 Routine/Complete Inspection No Violations Noted Remarks: Arrived at site at: 10:00. Weather conditions: Sunny, warm, ~80 degs. Onsite to perform routine insp of the Costello 1V well, the only well drilled on this pad. Most recent remedial activities were completed on this well back in Sept. and Oct. of 2014. This remedial work included; - Removal of ~ 1776' of 4 1/2" csg. and milling the entire 7" Intermediate casing string, approx. 1500', out of wellbore. Following this work wellhead was connected to Total Flow Control Unit (TFCU) to monitor any venting that may be occurring. At time of inspection reading taken off the TFCU showed no measureable vent flow detected ¿Static¿, with a cumulative reading of 12.75 cf/d. Vent line from TFCU was ran to a small poly vent tank. A gas check was performed in the vent tank lid opening showed, 0% LEL, 0% CH4. No indications of recent activities were observed at site and no further concerns were noted. No violations noted. Left site at 10:15.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1713937 541449 06/03/2008 2008-06-03 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1774894 557992 02/18/2009 2009-02-18 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative
1960308 607474 03/22/2011 2011-03-22 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety NERO EC&B Act 2 ROL granted 7/5/11.
1960308 607475 03/22/2011 2011-03-22 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102. Administrative NERO EC&B Act 2 ROL granted 7/5/11.
1960308 607476 03/22/2011 2011-03-22 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative NERO EC&B Act 2 ROL granted 7/5/11.
1960308 607477 03/22/2011 2011-03-22 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative NERO EC&B Act 2 ROL granted 7/5/11. 402-potential pollution
1960308 607478 03/22/2011 2011-03-22 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative NERO EC&B Act 2 ROL granted 7/5/11. SWMA 6018.401 violation for discharge of hazardous waste

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
541449 235107 NOV - Notice of Violation Comply/Closed 2008-06-26
557992 244244 NOV - Notice of Violation Superseded 2010-04-15
557992 252129 COA - Consent Order and Agreement Superseded 2010-04-15 $120,000.00 $120,000.00

For data sources see[8]