Well ID: 37-115-21639 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.6757,"lon":-76.032325,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Auburn Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 150816 | |
Farm/Lease Name: ANDERSON R 8 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-01-21 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.6757 | |
Longitude: -76.032325 |
Date | Event |
---|---|
2014-01-21 | New Permit Application |
2014-03-05 | Performed Spud Operation |
2014-05-09 | Drilling Completion |
2014-08-22 | Perforation |
2014-09-16 | Performed Stimulation |
2015-02-02 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-09-15 | 2014-10-14 | 7,350 | 7,500,530 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PA Specific 40/70 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Titanium Oxide | 13463-67-7 | 0.1 | 0.010162 | 0 |
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 10.1516 | 0 | ||||
Aluminum Oxide | 1344-28-1 | 1.1 | 0.111779 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.010162 | 0 | ||||
Water | CABOT OIL & GAS | Water | Water | 7732-18-5 | 100 | 88.6778 | 0 | |
WFR-6W | Nabors Completion and Production Services | Friction Reducer | Water | 7732-18-5 | 40 | 0.032615 | 0 | |
AQUCAR DB 20 | Nabors Completion and Production Services | Biocides | 2,2-Dibromo-3-nitrilo-propionamide (DBNPA) | 10222-01-2 | 20 | 0.005597 | 0 | |
Sodium bromide | 7647-15-6 | 4 | 0.001119 | 0 | ||||
Polyethylene glycol | 25322-68-3 | 54.5 | 0.015253 | 0 | ||||
Dibromoacetonitrile | 3252-43-5 | 3 | 0.00084 | 0 | ||||
PA Specific 100 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Titanium Oxide | 13463-67-7 | 0.1 | 0.000582 | 0 | |
Aluminum Oxide | 1344-28-1 | 1.1 | 0.006397 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 0.580923 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.000582 | 0 | ||||
Super TSC 2 LT | Nabors Completion and Production Services | Paraffin & Scale Additives | Bis(hexamethylene triaminepenta (methylenephosph onic acid)) |
Proprietary | 10 | 0.00217 | 0 | |
Acid Inhibitor 2 (AI-2) | Nabors Completion and Production Services | Acid Corrosion Inhibitors | Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.000107 | 0 | |
Isopropyl Alcohol | 67-63-0 | 40 | 0.000328 | 0 | ||||
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00008200 | 0 | ||||
Glycol Ethers | 111-46-6 | 40 | 0.000328 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 40 | 0.000328 | 0 | ||||
HCL Acid 15% | Nabors Completion and Production Services | Bulk Acid | Hydrochloric Acid | 7647-01-0 | 15 | 0.067036 | 0 | |
Other Ingredients | Nabors Completion and Production Services | Other Ingredients | Surfactant Blend | Proprietary | 3 | 0.002446 | 0 | |
Ethylene Glycol | 107-21-1 | 4 | 0.003262 | 0 | ||||
Monobromo-3-nitrilopropionamide | 1113-55-9 | 1 | 0.00028 | 0 | ||||
Ethoxylated alcohols | Proprietary | 4 | 0.003262 | 0 | ||||
Water | 7732-18-5 | 85 | 0.379869 | 0 | ||||
Water | 7732-18-5 | 90 | 0.019534 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 13 | 0.000107 | 0 | ||||
Copolymer | Proprietary | 100 | 0.081538 | 0 | ||||
Sodium Hydroxide | 1310-73-2 | 1 | 0.000217 | 0 | ||||
Water | 7732-18-5 | 48 | 0.000393 | 0 | ||||
Water | 7732-18-5 | 32 | 0.008956 | 0 | ||||
Dioxane | 123-91-1 | 1 | 0.00000800 | 0 | ||||
Isoparaffinic Solvent | 64742-47-8 | 26 | 0.0212 | 0 | ||||
2,2-Dibromomalonamide | 73003-80-2 | 1 | 0.00028 | 0 | ||||
2-Propenamide as residual | 79-06-1 | 0.1 | 0.00008200 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-09-16 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | 600,019.24 | 68 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 1,734,902.99 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,844,538.56 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 802,672.33 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 659,671.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 462,069.00 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | Produced Fluid | 1,096.26 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 426.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Drill Cuttings | 1,258.54 Tons | LANDFILL | 100933 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 12,864.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 1,271.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 3.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 227.41 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 635.74 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 82.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 208.15 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.26 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 232.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 57.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 254.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 21.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2253640 | Primary Facility | 2014-03-12 | Drilling/Alteration | No Violations Noted | Conductor set. Crew working on cellar. |
2265248 | Primary Facility | 2014-04-23 | Drilling/Alteration | No Violations Noted | 13 3/8 pipe split during bop test at approx 30' |
2265509 | Primary Facility | 2014-02-25 | Drilling/Alteration | No Violations Noted | redressing top of pipe at 45' preparing for second run of overshot tool 11:45 am |
2266751 | Primary Facility | 2014-04-21 | Drilling/Alteration | No Violations Noted | While in the process of surveying the secondary containment systems and chemical storage at the site, I observed what appeared to be oil or a dark viscous substance leaking from a hose. There were tears in this containment close to where the leak from the hose was discovered and I also noticed compromised integrity in other areas of this containment system. The secondary containment system for the light tower in the backyard was not properly secured. . A request for approval of an Alternative Waste Management Practice (OG-71) application needs to be submitted to the Department for the solids control process. The request for an OG-71 approval encomapsses both the use of centrifuges for seperation of solid and liquid material in the drill cuttings during oil and water based mud drilling and the injection of the chemicals mentioned above used for flocculation during water based mud drilling. |
2321615 | Primary Facility | 2014-11-12 | Incident- Response to Accident or Event | No Violations Noted | Arrived at the site at 10:15 in response to a reported spill of (5) barrels, (210) gallons of flowback fluid to the ground surface of the tank pad. Brody Webster, Steve Watson and Bob Raup, Environmental Health and Safety Specialists of Cabot Oil and Gas were at the site during the inspection. There was no activity on the tank pad. Flowback procedures for all the wells at the site have recently concluded. Erick Flowback Services was subcontracted by Cabot to conduct flowback procedures. Mr. Webster reported the spill to the Department at 12:18 on 11/10/14. He also reported an additional flowback fluid spill of less than (1) barrel, (42) gallons in volume discovered on the tank pad on 11/10/14. He explained that the flowback fluid spill where (5) barrels impacted the tank pad surface, occurred due to a butterfly valve left open on a frac tank during the transfer of flowback fluid from the well pad to the tank pad. |
2524750 | Primary Facility | 2016-10-04 | Administrative/File Review | No Violations Noted | Reviewed Well Site Restoration Report received on 22SEP2016 |
2677530 | Primary Facility | 2017-12-15 | Routine/Complete Inspection | No Violations Noted | Arrived on location at: 13:30. Weather: Clear, Cold, ~ 20 degs. A total of (10) wells were present on this pad, the Anderson, R. 1H, 2H, 3H, 4H, 5H, 6H, 7H, 8H, 9H and 10H. All (10) wells were in production at time of inspection. -All wells Prod. Line, Prod. casing, Static and Differential pressures were being monitored by wireless press. monitoring units sending pressures to an onsite Total Flow Control Unit "TFCU". The TFCU Control Panel was password protected, no pressures were accessible at time of inspection. All wells (13x9) and (9x5) annuli were open and venting, plumbed to (2) shared, common vent tanks. These annuli were also equipped with wireless press. monitoring units. A Gas check performed at both shared, common vent tanks showed 100% LEL, 100% CH4. -*Due to the commingling of the wells (13x9) and (9x5) annular vents to these vent tanks, a follow-up inspection will need to be scheduled with Operator to check the (13x9) cemented annuli for any sustained presence of gas. Please contact me when the |
2679709 | Primary Facility | 2018-01-04 | Routine/Complete Inspection | No Violations Noted | Arrived on location at: 10:45. Weather: Light snow, Cold, ~ 20 degs. A total of (10) wells are present on this pad, the Anderson, R. 1H, 2H, 3H, 4H, 5H, 6H, 7H, 8H, 9H and 10H. All (10) wells were in production at time of inspection. -All wells Prod. Line, Prod. casing, Static and Differential pressures were being monitored by wireless press. monitoring units sending pressures to an onsite Total Flow Control Unit "TFCU". The TFCU Control Panel was password protected, no pressures were accessible at time of inspection.
-Onsite in follow-up to initial inspection performed on 12/15/17 which detected 100% LEL and 100% CH4 at both shared annuli vent tanks. In preparation for this follow-up inspection, Cabot has isolated all (10) wells (13x9) annular vents. These vents were isolated and opened to vent to atmosphere at approx. 10:00 this morning. Upon arrival to site I met with Cabot Rep. Aaron Ungst. Gas checks were performed at the (13x9) block & bleed needle valves using an Altair 5X gas meter calibrated this |
2714149 | Primary Facility | 2018-04-04 | Site Restoration | No Violations Noted | I performed a RTNC inspection of the Anderson well site. The access road and pad surface were stable and solid despite overnight rain. The cut slope was well vegetated, greater than 70% perennial coverage. The fill slope was very well vegetated, exceeding the 70% perennial vegetative standard. The wells were properly labeled. There were no temporary BMPs remaining on site. There were no erosional issues observed.
The wells associated with this site are as follows: 115-21632 115-21633 115-21634 115-21635 115-21636 115-21637 115-21638 115-21639 115-21640 115-21641 There were no violations noted. |
2724258 | Primary Facility | 2018-04-27 | Routine/Complete Inspection | No Violations Noted | I inspected the Anderson Well Site on 4/27/2018. The wells associated with this site are as follows: 115-21632, 115-21633, 115-21634, 115-21635, 115-21636, 115-21637, 115-21638, 115-21639, 115-21640, 115-21641. The wells were all properly labeled.
The cut and fill slopes were both well vegetated and stable. The access road and pad surfaces were stable and solid. There were no erosional issues apparent. There were no violations noted. |
For data sources see[9]