Well Details

Well ID: 37-115-21722
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Choconut Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 151373
Farm/Lease Name: COREY 07 089 01 J 1H
License Status:
Spud Date:
Permit Date: 2014-05-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.977211
Longitude: -76.045767

For data sources see[1][2][3]

Well History

Date Event
2014-05-02 New Permit Application
2014-08-08 Performed Spud Operation
2014-10-09 Drilling Completion
2014-10-20 Perforation
2014-10-29 Performed Stimulation
2015-04-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-07 2014-11-07 5,540 5,652,320 20,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00000800 5.00724
Other Chemicals Water 7732-18-5 0 0 0
Trade Secret Proprietary 0 0 0
Acrylamide 79-06-1 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
3 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 3.5 0.004826 2920.89
7 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 7.5 0.010725 6491.26
Water Customer Carrier Water 7732-18-5 100 77.9376 47,170,900.0
White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 8.65161 5,236,300.0
LSI-21 (Scale Inhibitor) Trican Scale Inhibitor Sodium Salt of Phosphate Ester 68131-72-6 15 0.003767 2280.04
Acrylic Polymer 28205-96-1 15 0.003767 2280.04
FEAC-20 (Iron Control) Trican Iron Control Citric acid 77-92-9 30 0.000586 354.513
Acetic acid 64-19-7 45 0.000879 531.769
100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.73855 4,683,680.0
White 30/50 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 5.26272 3,185,210.0
AQUCAR DB 5 (Water Treatment Microbiocide) Trican Biocide Dibromoacetonitrile 3252-43-5 0.5 0.000129 78.0281
Polyethylene glycol 25322-68-3 65.2 0.016811 10174.9
Sodium Bromide 7647-15-6 1.5 0.000387 234.084
2,2-dibromo-3-nitrilopropionamide 10222-01-2 5 0.001289 780.281
FR-17 (Friction Reducer) Trican Friction Reducer Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.020999 12709.4
Ethylene Glycol 107-21-1 3 0.00225 1361.72
Ethoxylated alcohols Proprietary 4 0.003 1815.63
Polyacrylamide Proprietary 30 0.022499 13617.2

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-10-29 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 448,660.10 91 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 1,678,404.20 365 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 1,578,503.70 365 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 1,243,246.90 365 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 971,424.50 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 1,714.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 8,665.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 2,299.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 REPSOL OIL & GAS USA LLC Drill Cuttings 1,266.15 Tons LANDFILL 8-0728-0004/013
2015 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 2,030.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 21.14 Tons LANDFILL 100361
2015 REPSOL OIL & GAS USA LLC Produced Fluid 897.98 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 58.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 53.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 1,538.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 58.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 REPSOL OIL & GAS USA LLC Produced Fluid 3,854.20 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 113.34 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 598.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 56.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 REPSOL OIL & GAS USA LLC Produced Fluid 131.36 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Produced Fluid 2,399.42 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 232.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Produced Fluid 217.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 REPSOL OIL & GAS USA LLC Produced Fluid 1,226.69 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 66.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 725.05 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2264157 Primary Facility 2014-04-22 Administrative/File Review No Violations Noted
2266931 Primary Facility 2014-04-30 Routine/Partial Inspection No Violations Noted
2284108 Primary Facility 2014-07-03 Preoperation Inspection No Violations Noted The Department was on site at the Talisman Energy Choconut Valley Farms Well Site to conduct a Preoperational Inspection. The Well Permit issued for this pad is the Corey 1H 115-21722. The perimeter BMP's were in place and the pad was less than 40% complete. There were large wood chip piles on site which were in the process of being removed during inspection. Rock sumps for the culvert piping across the access road were in the process of being completed. Due to recent rain storm activity, progress on site was not as advanced as anticipated, however a post rain event inspection was recently completed. The most recent inspection activity was 7/2/2014. No violations noted. If you have any questions please contact me
2335305 Primary Facility 2014-12-31 Routine/Complete Inspection No Violations Noted The Department was on site at the Talisman Energy Corey Well Site to conduct a Routine Complete Inspection. The Well Permits issued for this pad are the Corey 1H (115-21722, 115-21723). The site was stable and there were no erosional issues at this time. The most recent inspection activity was 12/31/2014. No violations noted. If you have any questions please contact me.
2375390 Primary Facility 2015-06-01 Routine/Complete Inspection No Violations Noted The Department was on site at the Corey Well Pad to do a routine complete inspection of the erosion and sediment controls. The site was not well vegetated, and recently had a small slip near the corner of the pad on the cut slope. The site surface is hydroseeded with a tackifying agent, and the slip had been recently repaired with rip rap so it is now stable. There was no evidence of any sediment leaving the site, and there is a contractor scheduled to scarify and reseed all poorly vegetated areas.
2402445 Primary Facility 2015-08-27 Routine/Complete Inspection No Violations Noted
2462622 Primary Facility 2016-02-29 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a Routine Complete inspection of the Corey Well Site (ESX29-115-14-0043) The site was well vegetated and there were no erosional issues present at this time.

There are no violations.

If there are any questions please feel free to contact me.

2491430 Primary Facility 2016-06-08 Routine/Partial Inspection No Violations Noted The Department was on site to conduct a Routine Partial Inspection at the Corey Well Site located in Choconut Township, Susquehanna County. At the time of the inspection, the E&S Plan was on site and the E&S inspection log indicated that the most recent inspection was conducted on 5/29/16.

The Department noted that there are areas along the slopes on the access road that do not appear to meet temporary stabilization requirements. The Department requests that the operator deploy a method of temporary stabilization that is consistent with your E&S Plan within 3 days of receipt of this report.

In the area where the culvert (STA 18+50,Stream Crossing of the UNT to Choconut Creek -WWF/MF) is, there are rills running down the access road. Sediment laden water is running down these rills, across the road, down the rip rap fill slope, and into the UNT to Choconut Creek. The creek is being impacted with sediment laden water but is running clear upstream from this interference. This is a violation of the Penn

2498596 Primary Facility 2016-07-05 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:55a.m., the cellar had water at the bottom with no bubbling noticed, the (20x13) vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and peaked at 16% methane with no measurable flow. There was 1420psi on the production casing and 1149psi on the production tubing. The production line was connected to a separator and the bottom line was going to a 500bbl tank that was on containment and the valve was closed. I took a walk around the location and everything looked OK.

I left the site at 10:35a.m.

2504467 Primary Facility 2016-07-06 Follow-up Inspection No Violations Noted
2526660 Primary Facility 2016-09-26 Follow-up Inspection No Violations Noted The Department was on site to conduct a Follow-Up Inspection of the Corey Well Site access road in the vicinity of the areas of concern documented in the 6/8/2016 inspection. At the time of the inspection, the Department noted that the UNT to Choconut Creek was running clear. The area has been stabilized, and the side of the road has been built up and the material seems to be compacted. A filter sock sediment trap is located at the base of the road alongside the stream as an extra layer of protection. At the top of the slope (on the access road) “rip rap” is spray painted with two lines continuing toward the FSST. New filter sock has also been added and several water bars have been installed on the access road directing the flow of water to either side. The culvert outlet adjacent to the pipeline is still full of sediment and should be maintained. The pipeline interface also appears to be better vegetated than in previous inspections. The Department plans to return during an active rain event for a
2526797 Primary Facility 2016-09-29 Follow-up Inspection No Violations Noted
2544503 Primary Facility 2016-11-17 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a Routine Complete inspection of the Corey Well Site (ESX29-115-14-0043) The site was well vegetated and there were no erosional issues present at this time.

There are no violations.

If there are any questions please feel free to contact me.

2588470 Primary Facility 2017-04-27 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:15p.m.

The cellar was about a quarter full of water with no bubbling noticed. The (20x13) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) annulus vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and peaked at 38% methane with no measurable flow. There was 823psi on the production casing and 465psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:50p.m.

2628472 Primary Facility 2017-08-23 Routine/Complete Inspection No Violations Noted I inspected the Corey well site on August 1, 2017 and found the site to be stable and well vegetated at the time of inspection. The cut and fill slopes had strong vegetation and there did not appear to be any erosional issues or slides at the time of inspection. The pad surface was solid and stable, and the access road, shared with the Choconut Valley Farms well site, was acceptable. It had some washing visible however all waters off site were clear and there didnt appear to be any sediment off site.

There were no violations noted.

2696026 Primary Facility 2018-02-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 2.5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2795755 Primary Facility 2018-10-29 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1.5' below grade in the cellar and there was no bubbling noticed. The (20x13), (13x9) and (9x5) annuli were venting to the atmosphere. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]