37-115-21895

Well Details

Well ID: 37-115-21895
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Ararat Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 151969
Farm/Lease Name: LERNER G 5
License Status:
Spud Date:
Permit Date: 2014-10-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.795594
Longitude: -75.555317

For data sources see[1][2][3]

Well History

Date Event
2014-10-17 New Permit Application
2014-11-17 Performed Spud Operation
2014-12-11 New Permit Application
2015-01-20 Drilling Completion
2015-02-19 Perforation
2015-05-28 Performed Stimulation
2015-08-11 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-05-27 2015-06-10 7,558 12,621,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Plexslick 957 Chemplex Friction Reducer Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0246771 29509.1
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0287899 34427.2
Nonionic Surfactants Proprietary 1.5 0.00123385 1475.45
Ammonium Chloride 12125-02-9 5 0.00411285 4918.18
Sand TSS Proppant Silica Substrate 14808-60-7 100 11.1293 13,308,500.0
Chemplex 4-N-1 Chemplex Combination/Iron Control thiourea-formaldehyde copolymer 68527-49-1 2 0.00003588 42.9
Alcohol Ethoxylate Surfactants Proprietary 2 0.00003588 42.9
Acetic Acid 64-19-7 85 0.0015247 1823.25
n-olefins Proprietary 1 0.00001794 21.45
Diethanolamine 111-42-2 2 0.00003588 42.9
Propargyl Alcohol 107-19-7 1 0.00001794 21.45
Cocamide Diethanolamine Salt 68603-42-9 2 0.00003588 42.9
2-Ethylhexanol 104-76-7 10 0.000179377 214.5
Methyl Alcohol 67-56-1 10 0.000179377 214.5
Plexcide 15G Chemplex Biocide Glutaraldehyde 111-30-8 14 0.00304574 3642.12
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000652658 780.454
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000652658 780.454
Ethanol 64-17-5 3 0.000652658 780.454
Water Operator Carrier/Base Fluid Water 7732-18-5 100 88.4717 105,795,000.0
15% HCL Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.040322 48217.4
Greenhib 679 Chemplex Friction Reducer Glycerine 56-81-5 20 0.00487716 5832.15
Proprietary Proprietary 35 0.00853504 10206.3

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-05-28 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 759,052.30 186 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,310,792.44 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 874,626.81 361 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 781,625.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 684,678.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Drill Cuttings 831.82 Tons LANDFILL 101247
2015 CABOT OIL & GAS CORP Drilling Fluid Waste 55.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 5,909.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 13,283.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 51.05 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Fracturing Fluid Waste 23.09 Tons LANDFILL UT2300249
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 9,935.34 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CABOT OIL & GAS CORP Drill Cuttings 1,010.21 Tons LANDFILL 101247
2016 CABOT OIL & GAS CORP Produced Fluid 233.27 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Waste Water Treatment Sludge 3.74 Tons LANDFILL 301358
2016 CABOT OIL & GAS CORP Produced Fluid 8,237.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 3,099.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 347.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 70.12 Bbl REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 2,682.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 0.90 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 1,972.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 72.58 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 2,358.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 418.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 1,432.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 524.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 2,987.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2322844 Primary Facility 2014-11-19 Preoperation Inspection No Violations Noted On 11/19/14, the Department was on site at the COG Lerner E. Well Site and Tank Farm to conduct a Preoperational Inspection. The well permits that have been issued for this pad are the Lerner E 1H (115-21891), 2H (115-21892), 3H (115-21893), 4H (115-21894), 5H (115-21895), and the 6H (115-21896). All perimeter BMP’s in place to include red lined additions. Pad is 95% complete. 2 Spudder Rigs on-site prepping to drill. No violations noted.
2342847 Primary Facility 2015-01-14 Routine/Complete Inspection No Violations Noted Orion Drilling Rig #16 is the active drilling rig on the location currently drilling the lateral (horizontal) section of the G Lerner 5 H well at a depth of (12,187.89) feet with synthetic based drilling mud. I observed what appears to be a relatively small amount of oil based mud spilled to containment along with drill cuttings overflowing a container storing the cuttings onto containment in the backyard. Mr. Hornsby stated that a truck is on way to remove drill cuttings in the containers and on containment. I also observed a relatively small area of dark staining on the pad surface next to a frac tank near the diesel fuel tank.
2364798 Primary Facility 2015-04-24 Routine/Complete Inspection No Violations Noted On 4/24/15, the Department conducted an inspection of the well connect pipeline tie in occurring for the COG Lerner E. Well Pad. During the inspection, the Department identified violations related to the Well Pad. The Department observed that all of the well pad fill slopes were experiencing significant slope failures. Approximately 5% of the cut slopes were experiencing significant slope failures. Please address immediately. Enforcement record # 322504 is tied to inspection record # 2364703, the well pad site.
2364817 Primary Facility 2015-04-27 Administrative/File Review No Violations Noted Attached is correspondence related to the COG Lerner Slope failure identified by the Department on 4/24/15.
2379071 Primary Facility 2015-05-12 Routine/Complete Inspection No Violations Noted On 5/12/15, the Department conducted a follow up inspection of the COG Lerner E. Well Pad to assess the repairs conducted by Cabot to stabilize the pad slopes. As of this inspection, all violations noted in the inspection conducted on 4/24/15, inspection record # 2364703 and associated enforcement record # 322504 have been corrected. Approximately 90% of the failed slopes have been stabilized via rock stabilization. Attached to the inspection is a copy of Cabot’s written response to the 4/24/15 inspection. No further action is required of Cabot at this time by the Department.
2397727 Primary Facility 2015-07-28 Routine/Complete Inspection No Violations Noted Shortly upon arrival while in the process of surveying the production equipment and pad surface in the general area where this equipment is staged, I noticed small spots of dark staining in the southeast corner of the pad surface at N- 41° 47' 44”; 75° 33'17" near an Erick Flowback Services Gas Buster Tank. I used a Hanna Soil Test Electrical Conductivity & Temperature meter to screen the spots for soil conductivity. The highest conductivity reading I recorded was (2.9) milliSiemens/cm³. On average conductivity readings were in the range of (0.5-1) milliSiemens/cm³. I observed a white powdery substance spilled to the pad surface near where the treatment process equipment is staged. The material may be a chemical utilized in the process. GWTT indicated they would clean up this material spilled to the pad surface. Mr. Watson used yellow spray paint to mark off the area of the pad surface where the dark staining was discovered and indicated it would be remediated.
2421140 Primary Facility 2015-10-23 Routine/Complete Inspection No Violations Noted The Department was on site to perform a routine complete inspection at the Lerner G Well Pad (ESG29-115-14-0074). The wells associated with this site are:
2477056 Primary Facility 2016-04-21 Routine/Complete Inspection No Violations Noted
2498549 Primary Facility 2016-07-05 Routine/Complete Inspection No Violations Noted
2643345 Primary Facility 2017-09-06 Routine/Complete Inspection No Violations Noted Unable to inspect wells as heavy equipment on access road replacing cattle guard. Will return at later date
2643365 Primary Facility 2017-09-11 Routine/Complete Inspection No Violations Noted Heavy equipment onsite excavating to restore pad. No violations noted
2682169 Primary Facility 2018-01-03 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Well site is snow covered. No spills detected on pad. Good pad stabilization. No violations noted.
2684062 Primary Facility 2018-01-09 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was empty and there was no gas detected. The (20x13) annulus was open to atmosphere and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2779024 Primary Facility 2018-09-24 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 6' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2782082 Primary Facility 2018-09-25 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Site has good permanent stabilization. No E&S issues identified. No violations noted.
2798580 Primary Facility 2018-11-02 Routine/Complete Inspection No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permit termination. The Department’s determination is that the site does not meet the requirements for permit termination. The Post Construction Stormwater Management Plan provided with this NOT application does not reflect The as-built conditions. Primarily, the Stabilized Channel With S75 Matting does not exist. A buried cross culvert has been installed in its place. Please provide a revised Post Construction Stormwater Management Plan which accurately reflects site conditions with the next NOT submittal for this site. I recommend the NOT not be approved.
2828175 Primary Facility 2019-01-16 Site Restoration No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permit termination. The Department’s determination is that the site meets the requirements for permit termination. I recommend the NOT be approved.