Well ID: 37-127-20020 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.994506,"lon":-75.471667,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wayne | |
Municipality: Scott Township | |
Operator Name: HESS CORP | |
Well Pad ID: 146644 | |
Farm/Lease Name: DAVIDSON 1V | |
License Status: PLUGGED & ABANDONED | |
Spud Date: 2010-11-30 | |
Permit Date: 2010-07-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 41.994506 | |
Longitude: -75.471667 |
Date | Event |
---|---|
2010-07-13 | New Permit Application |
2010-11-25 | Performed Spud Operation |
2010-12-20 | New Permit Application |
2010-12-27 | Drilling Completion |
2013-05-23 | NEWLY DRILLED |
2013-10-26 | Drilling Completion |
2014-03-03 | FULLY PLUGGED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | HESS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | HESS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | HESS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | HESS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | HESS CORP | Drilling Fluid Waste | 2,700.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010 | HESS CORP | Servicing Fluid | 7.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD981737109 |
2010 | HESS CORP | Drill Cuttings | 1,350.00 Tons | LANDFILL | THR029 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1934103 | Primary Facility | 2010-12-09 | Drilling/Alteration | No Violations Noted | H&P 272. Hunter Copeland- Co. Man. Halliburton on site to cement 9 5/8" surface string. Used Type 1 cement. Bumped plug at 22:50. Observed good returns to pit. Halliburton estimated 15 bbls of good cement returned to surface. Pumped at rate of 6 bbls/min and then slowed down to @ 2 bbls/min near completion of job. |
1939179 | Primary Facility | 2010-12-12 | Routine/Complete Inspection | Violation(s) Noted | |
1941103 | Primary Facility | 2011-01-06 | Routine/Complete Inspection | No Violations Noted | Met with Hunter Copeland on site (Co. Man). H&P 272 on site. Drilling complete at this point. 5 1/2" casing set at 6533' and cemented to surface with good returns reported. Rig still set up. will be rigging down soon and will remove all equipment and clean up plastic etc... at that time. |
1971870 | Primary Facility | 2011-05-11 | Administrative/File Review | No Violations Noted | Follow-up to Insp ID 1939179, past 102.4(b)(1) & CSL 402 viols resolved. MBC 5/11/11 |
2000345 | Primary Facility | 2011-08-18 | Follow-up Inspection | Violation(s) Noted | Follow up inspection on report of bubbling in cellar. Met with Hess reps on location. Confirmed bubbling outside of 13 3/8" casing. Hess indicated bubbling is methane. Discussed with Hess that they will have 30 days to respond with plan to remediate problem of defective cement. Operator will supply DEP all infomration pertaiing to well including well logs, pre-drill and post-drill data, and any other pertinent information. DEP will revisit the site to collect gas sample, and will coordinate with Operator to sample. |
2005473 | Primary Facility | 2011-09-07 | Complaint Inspection | No Violations Noted | |
2059435 | Primary Facility | 2012-04-05 | Routine/Complete Inspection | No Violations Noted | Opeartor has filed for Inactive Status. Well has been temporarily plugged and shut in. Well head is barricaded with Chail Link Fencing. Gauge on well reading @ 900 psi on 5 1/2" prod string. No bubbling observed in cellar. Approximately 2' of water present in cellar. No activity on site. Entrance locked with gate. Site ID sign in place with proper information posted. Site appears clean. No violation observed at this time. |
2125277 | Primary Facility | 2012-12-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | On site with Co. Man. REported bubbling on 9 x 5" annulus. Well has been plugged and rig moved to next location. Upon completion of plugging activities - operator ovserved bubbling in 2" vent pipe on 9 x 5' annulus. Annulus was closed in for @ 10 days - no pressure bulid was observed. At time of inspection I observed bubbling in the 2" vent. occurs approximately every 10-15 seconds. Requested Hess provide a plan to DEP on addressing the issue. |
2159380 | Primary Facility | 2013-04-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | see paper file |
2175456 | Primary Facility | 2013-06-03 | Drilling/Alteration | No Violations Noted | |
2208599 | Primary Facility | 2013-09-24 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | CIBP's set @ 1400' and 1200'. Perfs from 770'-790'. Pump test, held 3000 psi, will require acid to open up for cementing. |
2208604 | Primary Facility | 2013-09-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | spotted 10% acid (estimated to be 7.5% at perfs due to dilution) @ perfs from 790'-770' , broke down @ 2500 psi and establish injection rate of .5 bbl/min @ 800psi. |
2208617 | Primary Facility | 2013-09-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 13.5 bbl. cement squeeze through retainer @ 750'. 8 bbls.into perfrs, final pump pressure of 3000 psi. Stung out of tool leaving the rest of the cement on top of retainer. Job went very well, good reactiion when cement reached perfs, good squeeze. |
2285043 | Primary Facility | 2014-07-02 | Routine/Complete Inspection | No Violations Noted | Inspection conducted on 7/2/14 with Bob Wrazen, URS and Dean Jameson, Hess of the Davidson Pad. Site has been temporarily stabilized. Vegetation has been established to about 60% perennial cover. |
2310715 | Primary Facility | 2014-09-25 | Site Restoration | No Violations Noted | Inspection conducted on 9/25/14 of the Hess Davidson Well Pad covered under ESCGP-1 ESX10-127-0003. The Davidson 1V (127-20020) has been drilled then P&A.The inspection was conducted to confirm Hess’s assessment that the site meets the minimum requirements as defined in Chapter 102.22(C) for permanent stabilization which would thus fulfill the physical requirements necessary for the permits termination. The Department’s determination is that the site is in fact permanently stabilized and meets the criteria necessary for the permit’s termination. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1939179 | 602036 | 12/12/2010 | 2010-12-12 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Silt sock was being undermined due to lack of maintenance or improper installation. See Insp ID 1971870, past viols resolved. MBC 5/11/11 |
1939179 | 602037 | 12/12/2010 | 2010-12-12 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Runoff from sump outlet foamy. Subsequent sampling by operator detected MBAS in the runoff. Subsequent sampling shows decreasing MBAS levels, 12/13/10 = 5.43 mg/L, 1/11/11 = 3.27 mg/L, 3/15/11 = 0.21 mg/L, past viols resolved. MBC 5/11/11 |
2000345 | 619308 | 08/18/2011 | 2011-08-18 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | |
2000345 | 619309 | 08/18/2011 | 2011-08-18 | 78.85 - Inadequate, insufficient, and/or improperly installed cement | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
602036 | 266998 | NOV - Notice of Violation | Comply/Closed | 2011-05-11 | |||
602037 | 266998 | NOV - Notice of Violation | Comply/Closed | 2011-05-11 |
For data sources see[7]