37-129-28134

Well Details

Well ID: 37-129-28134
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: XPR RESOURCES LLC
Well Pad ID: 149318
Farm/Lease Name: SLAVEK TRUST UNIT 3H
License Status:
Spud Date:
Permit Date: 2009-12-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.363083
Longitude: -79.331639

For data sources see[1][2][3]

Well History

Date Event
2009-12-21 New Permit Application
2010-02-02 Performed Spud Operation
2010-05-21 Drilling Completion
2010-10-16 Perforation
2013-04-29 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 REX ENERGY OPERATING CORP 0.00 0 0.00 0 0.00 0
2010 XPR RESOURCES LLC 257,690.02 68 0.00 0 0.00 0
2011 XPR RESOURCES LLC 524,964.46 292 0.00 0 0.00 0
2012 XPR RESOURCES LLC 511,402.22 366 0.00 0 0.00 0
2013 XPR RESOURCES LLC 564,853.50 360 0.00 0 0.00 0
2014 XPR RESOURCES LLC 421,500.61 364 0.00 0 0.00 0
2015 XPR RESOURCES LLC 360,328.67 365 0.00 0 0.00 0
2016 XPR RESOURCES LLC 288,745.69 366 0.00 0 0.00 0
2017 XPR RESOURCES LLC 413,772.90 365 0.00 0 0.00 0
2018 XPR RESOURCES LLC 177,098.00 360 0.00 0 0.00 0
2019 XPR RESOURCES LLC 159,695.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 XPR RESOURCES LLC Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 REX ENERGY OPERATING CORP Drilling Fluid Waste 2,170.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 REX ENERGY OPERATING CORP Drilling Fluid Waste 1,605.00 Bbl IDENTIFY METHOD IN COMMENTS
2011 XPR RESOURCES LLC Produced Fluid 330.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2011 XPR RESOURCES LLC Produced Fluid 50.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 XPR RESOURCES LLC Produced Fluid 10.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 XPR RESOURCES LLC Produced Fluid 295.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 XPR RESOURCES LLC Produced Fluid 1,223.98 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 625.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2013 XPR RESOURCES LLC Produced Fluid 116.55 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2014 XPR RESOURCES LLC Produced Fluid 1,067.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XPR RESOURCES LLC Produced Fluid 275.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 330.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2017 XPR RESOURCES LLC Waste comment only 0.00
2017 XPR RESOURCES LLC Produced Fluid 550.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 XPR RESOURCES LLC Produced Fluid 60.00 Bbl REUSE (AT WELL PAD)
2018 XPR RESOURCES LLC Produced Fluid 345.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XPR RESOURCES LLC Produced Fluid 420.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1864694 Primary Facility 2010-02-19 Routine/Complete Inspection No Violations Noted Well is being drilled currently.
1870176 Primary Facility 2010-02-25 Drilling/Alteration No Violations Noted MARCELLUS HORIZONTAL
1874312 Primary Facility 2010-03-26 Drilling/Alteration No Violations Noted
1881443 Primary Facility 2010-04-22 Drilling/Alteration No Violations Noted UDI 124 BUILDING THE NEGATIVE VERTICAL SECTION. SITE CLEAN.
1888179 Primary Facility 2010-05-26 Routine/Complete Inspection No Violations Noted Well is drilled and awaiting a frac.
2159165 Primary Facility 2013-04-09 Site Restoration No Violations Noted Inspection the result of an NOT received by the Department on 4/8/2013. At the time of inspection the well appeared to drilled and equipped for production. The well apparatus and brine tanks appear to be in sound working condition. The site appears to meet the restoration criteria of 70% uniform vegetative coverage. No observation of accelerated erosion and sedimentation in relation to the access road or well pad. The Department notes that the Operator has removed perimeter E&S controls. The site appears to meet the requirements set forth by the ESCGP-1 restoration and post construction water management plan. The Department approves the Operators request for the Notice of Termination, ESX09-129-0031.
2442030 Primary Facility 2016-01-14 Routine/Complete Inspection No Violations Noted Access road gated, locked and shared with ag field. At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized with no E& S issues in relation to site and/or access road.
2554700 Primary Facility 2017-01-24 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2621741 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok.
2690382 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Four brine tanks within secondary containment appear to be structurally sound. No E&S issues.

Site id sign updated to reflect current Operator information. PPC plan and ERP appears to reflect outdated Operator information. Department request Operator update documents accordingly in accordance with regulations. Violation issued (see inspection id 2690373).

For data sources see[7]

References