X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-041-20377"

m
 
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-041-20377
 
| Well ID: 34-041-20377
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.2596903799, -82.8353154993 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.25954775, -82.83534023 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Delaware County, Ohio|Delaware]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[MFC DRILLING INC]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 2010-08-06
 
| Spud Date: 2010-08-06
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Producing
 
|-
 
|-
 
| Violations: 0
 
| Violations: 0
 
|-
 
|-
| Latitude: 40.2596903799
+
| Latitude: 40.25954775
 
|-
 
|-
| Longitude: -82.8353154993
+
| Longitude: -82.83534023
 
|-
 
|-
 
|}
 
|}
Line 43: Line 43:
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
!scope="col" | OIL PRODUCTION DAYS
|}
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|}
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| -1439284041
+
| 2010-0
| 2014-01-29
+
| style="text-align:right;" | 0.0
|
+
|  
| Location Information.  ENTRANCE: Lat. 40.26025  Long. -82.83475 / WELL HEAD:  Lat. 40.25966  Long. -82.83528  / CENTER-OF-STORAGE: Lat. 40.26014  Long. -82.83402.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 0.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -1712977455
+
| 2011-0
| 2012-01-11
+
| style="text-align:right;" | 0.0
|
+
|
| The Division received a complaint alleging strong odor from this well, which is located across the street from residence at 12701 Centerburg Rd (CR 48).  The complainant states that smell of methane was astounding this morning caused headache and was smelled inside garage and house.  She has smelled odor in the past from this well, but felt that it was most strongest this morning.  An inspection revealed well equipped with a pumping unit and valves open.  The casing gas was routed to a electronic diaphragm.  An installed gauge showed 85 psi.  A 2" steel line transfers gas to a flare measuring approx 12" diameter casing with a height of approx 10'.  The setting for this diaphragm show "On Time" 5 minutes and "Off Time" 20 minutes.  20 psi was observed on gauge after regulator and connection into 1" plastic line.  This line is also routed to the flare.  A third gauge on casing side but located on opposite side showed 300 psi.  No gas sales from this well.  The wind blew to SW during inspection. Note: rainfall event today.  Odor was smelled but no detection with meter.  Areas checked were the well location, edge of Centerburg Rd at 12701 residence, flare and tank battery locations.  Charcoal filtration installed on 200 bbl oil tank.  Fumes from the 100 bbl saltwater tank are transferred to 200 bbl tank via 2" steel line routed from top of tank.  Flare not lit at time of inspection.  No violations were noted.  The well location contains a cyclone fence with 3 installed trees.  A GPS reading was obtained for well and tank battery location.
+
|
|
+
|  
|
+
| style="text-align:right;" | 338.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -2012840404
+
| 2012-0
| 2014-01-29
+
| style="text-align:right;" | 0.0
|
+
|  
| Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 118.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -645824578
+
| 2013-0
| 2012-01-11
+
| style="text-align:right;" | 0.0
|
+
|  
| An inspection revealed that the Preliminary Restoration meets ORC 1509.072.  The well is situated on a location designated as an agricultural field.  The well was equipped and showed signs of production.  A cyclone fence with 3 installed trees were observed.  The tank battery consisted of (1) 100bbl saltwater tank, (1) 200 bbl with charcoal filtration, separator, drip and flare.  Identification was displayed at the tank.
+
|  
|
+
|  
|
+
| style="text-align:right;" | 64.0
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -795098519
+
| 2014-0
| 2012-10-17
+
| style="text-align:right;" | 0.0
|
+
| style="text-align:right;" | 365.0
| Follow-up to the complaint inspection completed by Inspector Bear 1/11/2012. The flare stake is operational and no excess odors were detected. The tank battery has been freshly painted and the well identification and emergency contact information is clearly marked on tank #148593. Status OK.
+
|
|
+
|  
|
+
| style="text-align:right;" | 73.0
|
+
| style="text-align:right;" | 365.0
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
 +
| accessdate = 2015-06-20 }}</ref>
 +
== Inspection Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | INSPECTION ID
 +
!scope="col" | DATE
 +
!scope="col" | DESCRIPTION
 +
!scope="col" | COMMENT
 +
!scope="col" | VIOLATION ID
 +
!scope="col" | VIOLATION CODE
 +
!scope="col" | VIOLATION COMMENT
 
|-
 
|-
 
| 1288360124
 
| 1288360124
 
| 2010-10-29
 
| 2010-10-29
|
+
|  
 
| Service rig gone, no one at the site.
 
| Service rig gone, no one at the site.
The well head is plumed into a 500bbl frac tank.
+
The well head is plumed into a 500bbl frac tank.  
 
No odors at this time.
 
No odors at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1288615873
 
| 1288615873
 
| 2010-11-01
 
| 2010-11-01
|
+
|  
 
| On site (8:45am) as the result of several calls over the week end, complaining about odors.
 
| On site (8:45am) as the result of several calls over the week end, complaining about odors.
Has a slight gas odor at this time.
+
Has a slight gas odor at this time.  
 
No pumping unit or rods. No means of artificial lift. The well is plumed into a 500bbl frac-tank.
 
No pumping unit or rods. No means of artificial lift. The well is plumed into a 500bbl frac-tank.
 
The valves on the well head are closed at this time. Has a small leak around the 4.5 to 2 inch well head at the hammer ring.
 
The valves on the well head are closed at this time. Has a small leak around the 4.5 to 2 inch well head at the hammer ring.
 
Drilling pits closed, and the site has been graded. Top soil still stock piled, has not been put back on the site yet.
 
Drilling pits closed, and the site has been graded. Top soil still stock piled, has not been put back on the site yet.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1288698147
 
| 1288698147
 
| 2010-10-28
 
| 2010-10-28
|
+
|  
 
| On site as the result of a complaint by Don Davis of 12885 Centerburg Rd Sunbury Oh.
 
| On site as the result of a complaint by Don Davis of 12885 Centerburg Rd Sunbury Oh.
Mr. Davis said that the well is emitting a bad odor and that the site is covered with water and that mud is being drug out on to the road. He is concerned that the mud is contaminated. He also is concerned that the agricultural crop was contaminated when the well was drilled. Because of the dust that blew out on to it.
+
Mr. Davis said that the well is emitting a bad odor and that the site is covered with water and that mud is being drug out on to the road. He is concerned that the mud is contaminated. He also is concerned that the agricultural crop was contaminated when the well was drilled. Because of the dust that blew out on to it.  
 
A service rig is on site preparing to  swab the well into a 500bbl frac-tank. It does have a slught odor coming from the tank. the well was accidized on 10-27-10 and flowed back into the tank.
 
A service rig is on site preparing to  swab the well into a 500bbl frac-tank. It does have a slught odor coming from the tank. the well was accidized on 10-27-10 and flowed back into the tank.
The site has water on it form recent rains. The drilling pits are closed and the site has been graded. The top soil is still stock piled and has not been put back on the site yet.
+
The site has water on it form recent rains. The drilling pits are closed and the site has been graded. The top soil is still stock piled and has not been put back on the site yet.  
 
Later in the day I received several anonymous calls conserning the odors. One threatened to damage the well so as to render it unusable.
 
Later in the day I received several anonymous calls conserning the odors. One threatened to damage the well so as to render it unusable.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1288969055
 
| 1288969055
 
| 2010-11-05
 
| 2010-11-05
|
+
|  
 
| Check well and storage(10:55am), frac-tank may be leaking. Called and talked to Matt about the problem he said he would have the tank emptied as soon as possible.
 
| Check well and storage(10:55am), frac-tank may be leaking. Called and talked to Matt about the problem he said he would have the tank emptied as soon as possible.
 
Rods have been installed in to the well, pumping unit not set yet. Valves on the well head are closed at this time. No tank battery yet
 
Rods have been installed in to the well, pumping unit not set yet. Valves on the well head are closed at this time. No tank battery yet
 
1:00pm Vac-truck on site removing fluid from frac-tank.
 
1:00pm Vac-truck on site removing fluid from frac-tank.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1289315470
 
| 1289315470
 
| 2010-11-09
 
| 2010-11-09
|
+
|  
 
| On site (10:11am).
 
| On site (10:11am).
 
No one at the site, no production equipment yet.
 
No one at the site, no production equipment yet.
Frac-tank gone. No odors at this time.
+
Frac-tank gone. No odors at this time.  
 
Valves on the well head are closed at this time.
 
Valves on the well head are closed at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1291217936
 
| 1291217936
 
| 2010-12-01
 
| 2010-12-01
|
+
|  
 
| 10:30am light snow.
 
| 10:30am light snow.
 
A pumping unit and storage tanks are on the site but not hooked up yet.
 
A pumping unit and storage tanks are on the site but not hooked up yet.
 
The well is shut in at this time.
 
The well is shut in at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1292858609
 
| 1292858609
 
| 2010-12-20
 
| 2010-12-20
|
+
|  
| Pumping unit and storage tanks set, production line not hooked up
+
| Pumping unit and storage tanks set, production line not hooked up  
 
the site is snow covered at this time.
 
the site is snow covered at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1294841557
 
| 1294841557
 
| 2011-01-12
 
| 2011-01-12
|
+
|  
 
| Production equipment installed. Pumping unit is running at this time. Flair is burning. No odors at this time.
 
| Production equipment installed. Pumping unit is running at this time. Flair is burning. No odors at this time.
 
The site is snow covered.
 
The site is snow covered.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1354803410
 
| 1354803410
 
| 2012-12-06
 
| 2012-12-06
|
+
|  
 
| Check well and storage. Well is in production, site clean and identification marked. The flare stake is operational.
 
| Check well and storage. Well is in production, site clean and identification marked. The flare stake is operational.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| 1417035138
 +
| 2014-11-26
 +
|
 +
| Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage, identification and flare stack. Status: ok.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -1439284041
 +
| 2014-01-29
 +
|
 +
| Location Information.  ENTRANCE: Lat. 40.26025  Long. -82.83475 / WELL HEAD:  Lat. 40.25966  Long. -82.83528  / CENTER-OF-STORAGE: Lat. 40.26014  Long. -82.83402.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -1712977455
 +
| 2012-01-11
 +
|
 +
| The Division received a complaint alleging strong odor from this well, which is located across the street from residence at 12701 Centerburg Rd (CR 48).  The complainant states that smell of methane was astounding this morning caused headache and was smelled inside garage and house.  She has smelled odor in the past from this well, but felt that it was most strongest this morning.  An inspection revealed well equipped with a pumping unit and valves open.  The casing gas was routed to a electronic diaphragm.  An installed gauge showed 85 psi.  A 2 steel line transfers gas to a flare measuring approx 12 diameter casing with a height of approx 10'.  The setting for this diaphragm show On Time 5 minutes and Off Time 20 minutes.  20 psi was observed on gauge after regulator and connection into 1 plastic line.  This line is also routed to the flare.  A third gauge on casing side but located on opposite side showed 300 psi.  No gas sales from this well.  The wind blew to SW during inspection. Note: rainfall event today.  Odor was smelled but no detection with meter.  Areas checked were the well location, edge of Centerburg Rd at 12701 residence, flare and tank battery locations.  Charcoal filtration installed on 200 bbl oil tank.  Fumes from the 100 bbl saltwater tank are transferred to 200 bbl tank via 2 steel line routed from top of tank.  Flare not lit at time of inspection.  No violations were noted.  The well location contains a cyclone fence with 3 installed trees.  A GPS reading was obtained for well and tank battery location.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1767615661
 
| 1767615661
 
| 2010-09-07
 
| 2010-09-07
|
+
|  
| The well has just been drilled and not completed yet, no rods or tubing.
+
| The well has just been drilled and not completed yet, no rods or tubing.  
The pits have been closed.
+
The pits have been closed.  
 
The top soil is still stock piled and not put back on the site yet.
 
The top soil is still stock piled and not put back on the site yet.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -2012840404
 +
| 2014-01-29
 +
|
 +
| Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 509289219
 
| 509289219
 
| 2010-11-18
 
| 2010-11-18
|
+
|  
 
| No change since last inspecton.
 
| No change since last inspecton.
 
No production equipment sete yet.(light rain)
 
No production equipment sete yet.(light rain)
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -645824578
 +
| 2012-01-11
 +
|
 +
| An inspection revealed that the Preliminary Restoration meets ORC 1509.072.  The well is situated on a location designated as an agricultural field.  The well was equipped and showed signs of production.  A cyclone fence with 3 installed trees were observed.  The tank battery consisted of (1) 100bbl saltwater tank, (1) 200 bbl with charcoal filtration, separator, drip and flare.  Identification was displayed at the tank.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -795098519
 +
| 2012-10-17
 +
|
 +
| Follow-up to the complaint inspection completed by Inspector Bear 1/11/2012. The flare stake is operational and no excess odors were detected. The tank battery has been freshly painted and the well identification and emergency contact information is clearly marked on tank #148593. Status OK.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 08:42, 16 July 2015

Well Details

Well ID: 34-041-20377
Loading map...
County: Delaware
Municipality:
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2010-08-06
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 40.25954775
Longitude: -82.83534023

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-0 0.0 0.0
2011-0 0.0 338.0
2012-0 0.0 118.0
2013-0 0.0 64.0
2014-0 0.0 365.0 73.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1288360124 2010-10-29 Service rig gone, no one at the site.

The well head is plumed into a 500bbl frac tank. No odors at this time.

1288615873 2010-11-01 On site (8:45am) as the result of several calls over the week end, complaining about odors.

Has a slight gas odor at this time. No pumping unit or rods. No means of artificial lift. The well is plumed into a 500bbl frac-tank. The valves on the well head are closed at this time. Has a small leak around the 4.5 to 2 inch well head at the hammer ring. Drilling pits closed, and the site has been graded. Top soil still stock piled, has not been put back on the site yet.

1288698147 2010-10-28 On site as the result of a complaint by Don Davis of 12885 Centerburg Rd Sunbury Oh.

Mr. Davis said that the well is emitting a bad odor and that the site is covered with water and that mud is being drug out on to the road. He is concerned that the mud is contaminated. He also is concerned that the agricultural crop was contaminated when the well was drilled. Because of the dust that blew out on to it. A service rig is on site preparing to swab the well into a 500bbl frac-tank. It does have a slught odor coming from the tank. the well was accidized on 10-27-10 and flowed back into the tank. The site has water on it form recent rains. The drilling pits are closed and the site has been graded. The top soil is still stock piled and has not been put back on the site yet. Later in the day I received several anonymous calls conserning the odors. One threatened to damage the well so as to render it unusable.

1288969055 2010-11-05 Check well and storage(10:55am), frac-tank may be leaking. Called and talked to Matt about the problem he said he would have the tank emptied as soon as possible.

Rods have been installed in to the well, pumping unit not set yet. Valves on the well head are closed at this time. No tank battery yet 1:00pm Vac-truck on site removing fluid from frac-tank.

1289315470 2010-11-09 On site (10:11am).

No one at the site, no production equipment yet. Frac-tank gone. No odors at this time. Valves on the well head are closed at this time.

1291217936 2010-12-01 10:30am light snow.

A pumping unit and storage tanks are on the site but not hooked up yet. The well is shut in at this time.

1292858609 2010-12-20 Pumping unit and storage tanks set, production line not hooked up

the site is snow covered at this time.

1294841557 2011-01-12 Production equipment installed. Pumping unit is running at this time. Flair is burning. No odors at this time.

The site is snow covered.

1354803410 2012-12-06 Check well and storage. Well is in production, site clean and identification marked. The flare stake is operational.
1417035138 2014-11-26 Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage, identification and flare stack. Status: ok.
-1439284041 2014-01-29 Location Information. ENTRANCE: Lat. 40.26025 Long. -82.83475 / WELL HEAD: Lat. 40.25966 Long. -82.83528 / CENTER-OF-STORAGE: Lat. 40.26014 Long. -82.83402.
-1712977455 2012-01-11 The Division received a complaint alleging strong odor from this well, which is located across the street from residence at 12701 Centerburg Rd (CR 48). The complainant states that smell of methane was astounding this morning caused headache and was smelled inside garage and house. She has smelled odor in the past from this well, but felt that it was most strongest this morning. An inspection revealed well equipped with a pumping unit and valves open. The casing gas was routed to a electronic diaphragm. An installed gauge showed 85 psi. A 2 steel line transfers gas to a flare measuring approx 12 diameter casing with a height of approx 10'. The setting for this diaphragm show On Time 5 minutes and Off Time 20 minutes. 20 psi was observed on gauge after regulator and connection into 1 plastic line. This line is also routed to the flare. A third gauge on casing side but located on opposite side showed 300 psi. No gas sales from this well. The wind blew to SW during inspection. Note: rainfall event today. Odor was smelled but no detection with meter. Areas checked were the well location, edge of Centerburg Rd at 12701 residence, flare and tank battery locations. Charcoal filtration installed on 200 bbl oil tank. Fumes from the 100 bbl saltwater tank are transferred to 200 bbl tank via 2 steel line routed from top of tank. Flare not lit at time of inspection. No violations were noted. The well location contains a cyclone fence with 3 installed trees. A GPS reading was obtained for well and tank battery location.
1767615661 2010-09-07 The well has just been drilled and not completed yet, no rods or tubing.

The pits have been closed. The top soil is still stock piled and not put back on the site yet.

-2012840404 2014-01-29 Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
509289219 2010-11-18 No change since last inspecton.

No production equipment sete yet.(light rain)

-645824578 2012-01-11 An inspection revealed that the Preliminary Restoration meets ORC 1509.072. The well is situated on a location designated as an agricultural field. The well was equipped and showed signs of production. A cyclone fence with 3 installed trees were observed. The tank battery consisted of (1) 100bbl saltwater tank, (1) 200 bbl with charcoal filtration, separator, drip and flare. Identification was displayed at the tank.
-795098519 2012-10-17 Follow-up to the complaint inspection completed by Inspector Bear 1/11/2012. The flare stake is operational and no excess odors were detected. The tank battery has been freshly painted and the well identification and emergency contact information is clearly marked on tank #148593. Status OK.