X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-041-20377

Well Details

Well ID: 34-041-20377
Loading map...
Country: United States
State: Ohio
County: Delaware
Municipality: Trenton Township
Operator Name: MFC DRILLING INC
Well Pad ID:
Farm/Lease Name: CRIST SCOTT
License Status: Producing
License Date: 2009-12-21
Spud Date: 2010-08-06
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 2010-08-14
Well Total Depth: 3343.00 ft
Configuration: Vertical
Latitude: 40.250000
Longitude: -82.830000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-06-18 Proposed Formations:TRENTON/BLACK RIVER/TREMPEALEAU, Issued Date:6/18/2009, Expired Date:6/18/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2009-12-21 Proposed Formations:TRENTON/BLACK RIVER/TREMPEALEAU, Issued Date:12/21/2009, Expired Date:12/21/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-08-14
Completion Report Received 2010-12-16
Construction Permit Expires 2010-12-21
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-04-13 3237 3243 29
3237 3243 29
3237 3243 29

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-10-27 ACID 15 1125 Gal 0 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 MFC DRILLING INC 0.00 0.00 0
2011 MFC DRILLING INC 0.00 338.00 365
2012 MFC DRILLING INC 0.00 118.00 366
2013 MFC DRILLING INC 0.00 64.00 365
2014 MFC DRILLING INC 0.00 73.00 365
2015 MFC DRILLING INC 0.00 49.00 365
2016 MFC DRILLING INC 0.00 49.00 365
2017 MFC DRILLING INC 0.00 80.00 365
2018 MFC DRILLING INC 0.00 42.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 MFC DRILLING INC Brine 935 0
2011 MFC DRILLING INC Brine 0 365
2012 MFC DRILLING INC Brine 95 366
2013 MFC DRILLING INC Brine 120 365
2014 MFC DRILLING INC Brine 105 365
2015 MFC DRILLING INC Brine 89 365
2016 MFC DRILLING INC Brine 73 365
2017 MFC DRILLING INC Brine 71 365
2018 MFC DRILLING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1254427013 2017-7-17 0:00: PW No Violations
-1305571049 2016-8-23 0:00: PW No Violations
-1439284041 2014-1-29 0:00: PW No Violations
-1712977455 2012-1-11 0:00: PW No Violations
-1938070192 2019-3-12 0:00: PW No Violations
-2012840404 2014-1-29 0:00: PW No Violations
-258102605 2017-10-2 0:00: PW No Violations
-407483196 2018-10-25 0:00 PW No Violations
-636082944 2016-8-29 0:00: PW No Violations
-645824578 2012-1-11 0:00: PL No Violations
-72564331 2019-10-16 0:00 PW No Violations
-795098519 2012-10-17 0:00 PW No Violations
-833805610 2017-11-20 0:00 PW No Violations
-887939430 2017-6-16 0:00: PW No Violations
0258102605 2017-10-02 Production Wells No Violations Inspect well, storage, identification and flare stack. Status: ok, no odors noted.
0407483196 2018-10-25 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. The well was not pumping at the time of inspection. Odor noted at the storage and well with no wind.
0509289219 2010-11-18 Production Wells No Violations No change since last inspecton.

No production equipment sete yet.(light rain)

0636082944 2016-08-29 Production Wells No Violations Received re-complaint regarding odors from well. Contacted well tender who was going to begin manually dumping the separator into the storage, to see if this will make a difference in odors. Contacted complainant to update.
0638876100 2018-02-21 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. The flare stack is operational, no odors noted.
0645824578 2012-01-11 Preliminary Restoration No Violations An inspection revealed that the Preliminary Restoration meets ORC 1509.072. The well is situated on a location designated as an agricultural field. The well was equipped and showed signs of production. A cyclone fence with 3 installed trees were observed. The tank battery consisted of (1) 100bbl saltwater tank, (1) 200 bbl with charcoal filtration, separator, drip and flare. Identification was displayed at the tank.
0795098519 2012-10-17 Production Wells No Violations Follow-up to the complaint inspection completed by Inspector Bear 1/11/2012. The flare stake is operational and no excess odors were detected. The tank battery has been freshly painted and the well identification and emergency contact information is clearly marked on tank #148593. Status OK.
0833805610 2017-11-20 Production Wells No Violations Inspect well, storage, identification and flare stack. Status: ok, the flare stack was operational and no odors were noted during the inspection.
0887939430 2017-06-16 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Status: ok, the flare stack was operational, no odors noted.
1254427013 2017-07-17 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok, odor noted downwind of the flare stack, negligible at the road. Added location directions.
1288360124 2010-10-29 Production Wells No Violations Service rig gone, no one at the site.

The well head is plumed into a 500bbl frac tank. No odors at this time.

1288615873 2010-11-01 Production Wells No Violations On site (8:45am) as the result of several calls over the week end, complaining about odors.

Has a slight gas odor at this time. No pumping unit or rods. No means of artificial lift. The well is plumed into a 500bbl frac-tank. The valves on the well head are closed at this time. Has a small leak around the 4.5 to 2 inch well head at the hammer ring. Drilling pits closed, and the site has been graded. Top soil still stock piled, has not been put back on the site yet.

1288698147 2010-10-28 Production Wells No Violations On site as the result of a complaint by Don Davis of 12885 Centerburg Rd Sunbury Oh.

Mr. Davis said that the well is emitting a bad odor and that the site is covered with water and that mud is being drug out on to the road. He is concerned that the mud is contaminated. He also is concerned that the agricultural crop was contaminated when the well was drilled. Because of the dust that blew out on to it. A service rig is on site preparing to swab the well into a 500bbl frac-tank. It does have a slught odor coming from the tank. the well was accidized on 10-27-10 and flowed back into the tank. The site has water on it form recent rains. The drilling pits are closed and the site has been graded. The top soil is still stock piled and has not been put back on the site yet. Later in the day I received several anonymous calls conserning the odors. One threatened to damage the well so as to render it unusable.

1288969055 2010-11-05 Production Wells No Violations Check well and storage(10:55am), frac-tank may be leaking. Called and talked to Matt about the problem he said he would have the tank emptied as soon as possible.

Rods have been installed in to the well, pumping unit not set yet. Valves on the well head are closed at this time. No tank battery yet 1:00pm Vac-truck on site removing fluid from frac-tank.

1289315470 2010-11-09 Production Wells No Violations On site (10:11am).

No one at the site, no production equipment yet. Frac-tank gone. No odors at this time. Valves on the well head are closed at this time.

1291217936 2010-12-01 Production Wells No Violations 10:30am light snow.

A pumping unit and storage tanks are on the site but not hooked up yet. The well is shut in at this time.

1292858609 2010-12-20 Production Wells No Violations Pumping unit and storage tanks set, production line not hooked up

the site is snow covered at this time.

1294841557 2011-01-12 Production Wells No Violations Production equipment installed. Pumping unit is running at this time. Flair is burning. No odors at this time.

The site is snow covered.

1305571049 2016-08-23 Production Wells No Violations Received odor complaint and met complainant at wellsite. Inspection found flare stack operational and no odors noted on a windy day. Contacted operator who responded to location. They plan on repairing/replacing the charcoal barrel on top of the storage tank, updated complainant.
1354803410 2012-12-06 Production Wells No Violations Check well and storage. Well is in production, site clean and identification marked. The flare stake is operational.
1417035138 2014-11-26 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage, identification and flare stack. Status: ok.
1439284041 2014-01-29 Production Wells No Violations Location Information. ENTRANCE: Lat. 40.26025 Long. -82.83475 / WELL HEAD: Lat. 40.25966 Long. -82.83528 / CENTER-OF-STORAGE: Lat. 40.26014 Long. -82.83402.
1558018165 2019-05-16 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
1639696633 2020-4-21 0:00: PW No Violations
1712977455 2012-01-11 Production Wells No Violations The Division received a complaint alleging strong odor from this well, which is located across the street from residence at 12701 Centerburg Rd (CR 48). The complainant states that smell of methane was astounding this morning caused headache and was smelled inside garage and house. She has smelled odor in the past from this well, but felt that it was most strongest this morning. An inspection revealed well equipped with a pumping unit and valves open. The casing gas was routed to a electronic diaphragm. An installed gauge showed 85 psi. A 2 steel line transfers gas to a flare measuring approx 12 diameter casing with a height of approx 10. The setting for this diaphragm show On Time 5 minutes and Off Time 20 minutes. 20 psi was observed on gauge after regulator and connection into 1 plastic line. This line is also routed to the flare. A third gauge on casing side but located on opposite side showed 300 psi. No gas sales from this well. The wind blew to SW during inspection. Note: rainfall event today. Odor was smelled but no detection with meter. Areas checked were the well location, edge of Centerburg Rd at 12701 residence, flare and tank battery locations. Charcoal filtration installed on 200 bbl oil tank. Fumes from the 100 bbl saltwater tank are transferred to 200 bbl tank via 2 steel line routed from top of tank. Flare not lit at time of inspection. No violations were noted. The well location contains a cyclone fence with 3 installed trees. A GPS reading was obtained for well and tank battery location.
1767615661 2010-09-07 Production Wells No Violations The well has just been drilled and not completed yet, no rods or tubing.

The pits have been closed. The top soil is still stock piled and not put back on the site yet.

1838377481 2016-08-25 Production Wells No Violations The operator has removed the rusted charcoal barrel and secured/sealed the tank hatch. Flare stack was operational. No odors noted.
1938070192 2019-03-12 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
1950591731 2015-10-19 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
2012840404 2014-01-29 Production Wells No Violations Inspected the Crist #1 (#377) as part of a standard production well status check. Inspect well, storage and identification. Status: ok.
2033934008 2015-10-23 Preliminary Restoration No Violations The Crist #1 is in production. Preliminary restoration complete.
509289219 2010-11-18 0:00 PW No Violations
638876100 2018-2-21 0:00: PW No Violations

For data sources see[9]

References